Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> - <br /> COUNTY---- <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SIMPSON STRONG TIE CO 1255 PERFORMANCE DR, STOCKTON September 03, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR•Notice to Comply) <br /> Item# Remarks <br /> 301 CCR 66262.34(d)(2)Facility not maintained to minimize the release of a hazardous waste. <br /> OBSERVATION: In the main shop, oily metal fines were observed piled up in the band saw containment. <br /> REGULATION: Facilities shall be maintained and operated to minimize the possibility of a fire,explosion,or release <br /> of hazardous waste to air, soil,or surface water which could threaten human health or the environment. <br /> CORRECTIVE ACTION: Immediately clean the band saw and manage according to Title 22 hazardous waste <br /> regulations. Submit a statement and supporting documentation explaining how this waste was managed. <br /> This is a repeat violation, Class Il. <br /> 403 CCR 66262.34(d)(2)Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> OBSERVATION: In the main shop,one orange 5 gallon bucket containing oily metal fines was open. <br /> REGULATION: All hazardous waste containers shall be closed at all times except when adding or removing waste. <br /> CORRECTIVE ACTION: Immediately close the container and ensure all hazardous waste containers are closed <br /> when not adding or removing waste. <br /> This is a repeat violation, Class 11. <br /> 605 CCR 66262.34(f)Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: In the main shop, one orange 5 gallon bucket containing oily metal fines was observed missing a <br /> hazardous waste label. <br /> REGULATION: All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition(contents) <br /> -accumulation start date <br /> CORRECTIVE ACTION: Immediately label this container and ensure that all hazardous waste containers are <br /> marked with all the required information. <br /> This is a repeat violation, Class II. <br /> FA0015493 PR0539037 SCO01 09/03/2019 <br /> EHD 22-01 Rev.8/22/2019 Page 6 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />