Laserfiche WebLink
' 12 December 2005 <br /> AGE-NC Project No 97-0333 <br /> ' Page 11 of 11 <br /> Generally,the core of the dissolved MTBE plume appears to located in the First Zone within the area <br /> of wells EW-1, MW-1, MW-2, MW-3, MW-6, and MW-7A, outside of the dissolved MTBE core <br /> area, only low to very low MTBE concentrations have been detected on-site and off-site toward the <br /> north (MW-12B) in Second,Zone Based on the data collected during the second quarter 2005, <br /> additional ground water monitoring wells are not warranted at this time and the existing monitoring <br /> well network may be sufficient to complete a site Problem Assessment Report (PAR) <br /> 1 <br /> 6.0. LIMITATIONS <br /> ' Our professional services were performed using that degree of care and skill ordinarily exercised by <br /> environmental consultants practicing in this or similar localities The findings were based mainly <br /> ' upon analytical results provided by an independent laboratory Evaluations of the hydrogeologic <br /> conditions at the site for the purpose of this investigation are made from a limited number of <br /> available data points (i a ground water samples), and subsurface conditions may vary away from <br /> tthese data points No other warranty, expressed or implied, is made as to the professional <br /> interpretations, opinions, and recommendations contained in this report <br /> 1 <br /> 1 ' <br /> i <br /> ' Advanced GeoEnvironmentai,inc <br /> 1 <br />