My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
508
>
2300 - Underground Storage Tank Program
>
PR0231057
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 3:07:59 PM
Creation date
7/28/2020 8:15:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231057
PE
2361
FACILITY_ID
FA0003720
FACILITY_NAME
CHARTER WAY PETRO INC.
STREET_NUMBER
508
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16504016
CURRENT_STATUS
01
SITE_LOCATION
508 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID Date of Overfill Prevention Equipment Inspection <br />10181363 10/3/2018 <br />Business Name (Same as Facility Name or DBA -Doing Business As) <br />Charter Way Petroleum - CHARTER WAY CHEVRON <br />Business Site Address City ZIP Code <br />508 W CHARTER WAY STOCKTON, CA 95206 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br />Felix Ramirez (209) 744-0112 <br />Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br />08-1740 3-31-20 8883072 -UT 11/22/2018 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />FF -FF- EBW , PhikTite & EVR Phase 1 1009883708 EX 11-16-18 OPW 104-634 Ex 3-14-202.0, pv, J— T y <br />Emco 3147 Ex. 9-21-20 VR: B34976 ATG: 7/7/20 T, <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method 0 Manufacturer Guidelines (Specify): JAN 0 4 2019 <br />Used: REMOVED DROP TUBES <br />❑ Industry Code or Engineering Standard (Specify): <br />❑ Engineered Method (Specify): <br />Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages 3 <br />TANK ID: (By tank number, stored product, etc.) 87 91 87 <br />What is the tank inside diameter? (Inches) 112 112 112 <br />Is the fill piping secondarily contained? E Yes 0 No ❑ Yes i] No ❑ Yes E No ❑ Yes ❑ No <br />Is the vent piping secondarily contained? 0 Yes ❑ No 0 Yes ❑ No E Yes ❑ No ❑ Yes ❑ No <br />Overfill Prevention Equipment Manufacturer(s) oPw OPW OPw <br />71-50 61-50 71-50 <br />What is the overfill prevention equipment response Ex Shuts Off Flow x❑ Shuts Off Flow ❑x Shuts Off Flow ❑ Shuts Off Flow <br />when activated? <br />❑ <br />(Check all that apply.) ❑ <br />Restricts Flow Restricts Flow El Restricts Flow El Restricts Flow <br />❑ AN Alarm ❑ AIV Alarm ❑ AIV Alarm ❑ AIV Alarm <br />Are flow restrictors installed on vent piping? E Yes ❑x No ❑ Yes H No ❑ Yes ❑x No ❑ Yes ❑ No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank.) 101.5 101 101 <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? 95% 950jo 950o <br />Is the overfill prevention in proper operating condition Ex Yes ❑x Yes ❑x Yes ❑ Yes <br />to respond when the substance reaches the <br />appropriate level? ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results (] Pass E1 Fail ❑x Pass ❑Fail I Z Pass ❑Fail ❑Pass ❑ Fail <br />V. COMMENTS <br />Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, Title 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br />UST Service Technician Signature <br />If the facility has more components than this form accommodates, additional copies of this page maybe attached. <br />CERS = California Environmental Reporting System, ID =Identification, UST =Underground Storage Tank, ICC = Intemafional Code Coundl, AN =Audible and Vi <br />sual <br />
The URL can be used to link to this page
Your browser does not support the video tag.