My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
620
>
2300 - Underground Storage Tank Program
>
PR0231058
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2021 8:11:04 AM
Creation date
7/28/2020 8:25:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231058
PE
2361
FACILITY_ID
FA0003738
FACILITY_NAME
CHARTER WAY SHELL*
STREET_NUMBER
620
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
Stockton
Zip
95206
APN
16504007
CURRENT_STATUS
01
SITE_LOCATION
620 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,111r1 � 96 � ®. . r <br /> 12 , 000 Gallon Tanks (Actual Capacity 11 , 627 gall) Fliberglas Tanks <br /> Dipstick ' Gallons Dipstick Gallons' Dipstick ' Gallons Dipstick Gallons Dipstick ' Gallons for Fuel Storage <br /> /a " 1 8 '/s " 473V1611/,�, 1302 24 ?/a " 2347 321/6 " 3538 <br /> '/a " 3 8 ?'a " 484 1317 24 Ya " 2364 32 '/./ 11 3558 Calibration <br /> 5 83/8 " 495 1332 243/0 " 2382 32;/811 3577 <br /> 112 " 7 81/2 " 506 1347 241/ 11 2400 3211 " 3597 <br /> How to properly gauge your <br /> 10 8% 517 1362 245/x " 2417 32% 3617 tank : . . . <br /> 3/4 " 14 83/4 528 16 /1 1377 243/4 " 2435 3231, " 3636 Underground storage tanks require <br /> 17 8 % fl 539 16r/13 " 1392 247,8 " 2453 32'/a ° 3656 periodic measurement todeterminecur- <br /> 1 " 21 9 " 550 17 " 1407 2.5 " 2471 33 " 3676 rent inventory level . Using the proper <br /> methods when gauging your tank' s con , <br /> 1 '/8 " 25 91/811 561 171/8 " 1423 251/4 " 2489 331/8 " 3695 tents will insure the most accurate reading <br /> _ 11/4 " 29 91/4 " 573 17 !14 " 1438 251/4 " 2506 331/4 " 3715 and insure that you do not darnage your <br /> 13/8 " 34 9% If 584 173,8 " 1453 25318 " 2524 333/8 " 3735 tank . The following procedure should be <br /> followed whenever you use a gauge stick <br /> 1112 " 38 91/2 " 596 171;'2 " 1469 25112 " 2542 331/2 " 3754 to determine the amount of product that is <br /> 15/8 " 43 95/8 ' 608 175/8 " 1484 255/8 " 2560 331Aif3774 1n your tank: <br /> 13/4 " 48 93/4 " 619 173/4 1500 253/4 " 2578 333/4 " 3794 1 . Use a wood dipstick with a rubber or <br /> 17/8 " 53 97/8 " 631 17 ?/8 " 1515 257/x " 2596 337/8 " 3814 nylon tip. Metallic dipsticks are not <br /> 2 " 59 10 " 643 18 " 1531 26 " 2615 34 " 3834 recommended . This will insure that fre- <br /> 2ya " 64 101/811 655 181/8 " 1546 26 '/6 " 2633 341/8 " 3854 doquent inn of <br /> the <br /> e 1 acus e sor ack into the <br /> 2114 " 70 101/4 667 181/4 " 1562 261/4 " 2651 341/4 " 3873 tank dropping <br /> lgnot damage the tank bottom . <br /> 23/8 " 76 103/x " 679 183/13 " 1578 263/0 " 2669 3436 " 3893 2 . Always gauge your tank at the fill <br /> 21/2 " 82 10112 " 691 181/2 " 1594 261/2 " 2687 341/2 " 3913 port A tank bottom protector plate has <br /> 25/8 " 88 105/8 " 703 185/8 " 1609 26% 11 2706 345/x " 3933 been installed under this port to help <br /> protect the tank . <br /> 231411 94 103/4 " 715 18344 " 1 1625 263/4 " 2724 343/4 " 3953 <br /> 27/8 " 101 107/811 727 187/8 " 1641 267/8 " 2742 347/8 " 3973 3 . Slowly lower your gauge stick into the <br /> till port until it touches the tank bottom. <br /> 3 " 108 lit? 740 19 " 1657 27 " 2761 35 " 3993 Never free drop the gauge stick. This <br /> Sys " 114 11318 " 752 19 !8 " 1673 271/a " 2779 35ya " 4013 can result in inaccurate measurements <br /> 3 'A l' 121 111/4 It 765 191/'111 1689 271/4 It 2797 351/4 " 4033 due to product splashing. Free drop* <br /> 3 % 11 128 11 % 11 777 1_93/8 " 1705 273/8 " 2816 353x8 " 4053 ping can also result in gauge stick <br /> damage and tank damage. <br /> 31/2 " 135 11 '12 " 790 191/2 " 1721 271/2 " 2834 3511 " 4073 4 . Remove your dipstick slowly and <br /> 35/8 " 143 115/g " 1 803 195/e " 1738 275/8 " 2853 1 355A 4094 read the product level directly from the <br /> 33/4 150 113/4 " 815 19314 " 1754 273/4 " 2871 353/8 " 4114 gauge stick . <br /> 37/8 " 157 117/8 " 828 19 %ff 1770 277/8 " 2890 357/8 " 4134 <br /> 4 " " " "165 12 841 20 1786 28 " 2909 36 4154 Water Paste Detection <br /> To detect water in the tank bottom , water <br /> 41/811 . ", 173 121/8 „ 854 201/8 " 1803 281/8 " 2927 36 '/a " 4174 detection paste is available from <br /> 4114 " 181 121/4 " 867 20114 1819 281/4 " _ 2946 361/4 " 4194 petroleum equipment distributors. <br /> 43/8 " 189 12% 11 880 203/8 " 1835 283/8 " 2965 363/8 " 4215 However , some water detection paste <br /> cannot detect antifreeze mixtures. If <br /> 41/2 " 197 121/2 " 893 201;2 " 1852 281/2 " 2983 361/2 " 4235 antifreeze mixtures are used for the cavity <br /> 45/8 " 205 12% 11 906 205/8 " 1868 285/x " 3002 365/8 " 4255 monitoring fluid, the following product is <br /> 43/4 " 213 ' 123/4 919 2 03/4 " 1885 283/4 " 3021 363/4 " 4275 capable of detecting water or antifreeze <br /> 47/8 " 222 127/8 " 933 207/8 " 1902 287/8 " 3040 3678 11 4296 ( noneoruptopercent glycol) solution <br /> / in the tank water <br /> bottoms : <br /> 5 " 230 13 " 946 21 " 1918 2911 3059 37 " 4316 <br /> WATER FINDER <br /> 51/811 239 131/8 " 959 21 ye " 1935 291/8 " 3077 371/6 " 4336 # 7686 - 1870 <br /> 51/4 " 247. 131/4 " 973 211/4 " 1952 291/4 " 3096 371/4 " 4357 DAYCOINATiONAL <br /> 5% 11 256 133/8 " 986 21318 " 1968 293/8 " 3115 373/8 " 4377 Dayton , OH <br /> 51/2 " 265 131/2 " 1000 211/2 " 1985 291/2 " 3134 371/2 " 4397 (513) 226 5879 <br /> 55/8 " 274 13% 11 1414 215/8 " 2002 295/8 " 3153 37% 01 4418 Caution <br /> 53/4 " 283 13-/4 " 1028 213/4 " 2019 293/4 " 3172 373/4 " 4438 Pressurized deliveries are not recom- <br /> 57/s " 292 137/8 " 1042 ` 217/a " 2036 297/8 " 3191 377/8 " 4459 mended . ii the deliveryk , install <br /> ovehicle uses <br /> _ pumps to fill the tank , install overfill shut* <br /> 6 " 1302 ` 14 " 1056 22 ° _ 2053 30 " 3210 38 " 4479 off equipment in the tank and truck to pro, <br /> 61/8 " 311 141/8 " 1070 22 ye " 2070 30 '/8 " 3229 38 '/8 " 4500 vent the tank from being overfilled . Over* <br /> 61/411 321 141/4 " 1084 221/4 " 2087 30 '/4 " 3249 381/x " 4520 filling the tank under pressure will <br /> damage the tank even if the tank vent <br /> 63/8 " 330 143/8 " 1098 22% 11 2104 303/x " 3268 1 38% $f 4541 is unrestricted . <br /> 61/2 " 340 141/2 " 1112 221/2 " 2121 301/2 " 3287 381/2 " 4561 <br /> 65/8 " 350 145/8 " 1127 225/6 " 2138 305/8 " 3306 385/8 " 4582 <br /> 63/4 " 359 143/4 " 1 1141 223/411 1 2155 303A 3325 383/4 " 4602 <br /> 67/8 " 369 147/8 " 1155 227/x " 2172 307/8 " 3345 381t10 " 4623 For Model DWT-2P double-wall <br /> 7 " 379 15 " 1170 23 " 2190 311, 3364 39 " 4643 tanks only , the annular space <br /> 71/8 " 389 151/8 " 1184 231/8 " 2207 311/8 " 3383 391,/8 " 4664 capacity for this tank is 585 gallons. <br /> 71/4 " 400 151/4 " 1199 231/4 " 2224 311/4 " 3402 391/4 " 4684 <br /> 7% 11 410 153/8 " 1213 23%11 22.42 313/x " 3422 39% 11 4705 <br /> 71/2 " 420 15 '/2 " 1228 231/2 " 2259 311/2 " 3441 391/2 " 4726 <br /> 75/e " 430 1 15% 11 1243 235/x " 2276 315/8 " 3461 393'x " 4746 <br /> 73/4 " 441 15314 " 1257 233/4 " 2294 313/4 " 3480 393/4 " 4767 <br /> 71/8 " 452 157/8 " 1272 237/x " 2311 317/8 " 3499 1 397/8 " 4788 ' <br /> 8 " 462 16 " 1287 24 " 2329 32 " 3519 40 " 4808 <br />
The URL can be used to link to this page