Laserfiche WebLink
AJ O A U IN Environmental Health Department <br /> OUITY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DSS COMPANY 655 W CLAY ST, STOCKTON Jul 26, 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on JUly 24, 2018 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by August 23, 2018 . <br /> This information has not been received resulting in a non-compliant status for this facility. An operator that receives <br /> an inspection report shall have 30 days to submit a written response that includes a statement documenting <br /> corrective actions taken or proposing corrective actions which will be taken. Ensure that a written response <br /> documenting corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to use the approved monthly visual inspection report form. On or after October 1, <br /> 2018 the designated operator was required to conduct all visual inspection report on the current form. The <br /> designated operator visual inspections shall be conducted within 30 days or less of the previous inspection. Ensure <br /> that all designated operator inspections are performed within the required time frames and on the approved <br /> designated Underground storage tank operator visual inspection report. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by August 25, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> Documents provided: Return to Compliance Certification Form and a list of scheduled free CUPA classes. <br /> Noted that diesel auto dispenser is suction system and does not utilize sensors for shutdown HI FLO TURBINE <br /> does shut down with dispenser sensor. <br /> FA0003699 PR0231065 SCO01 07/26/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />