COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3223
>
1600 - Food Program
>
PR0523276
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2020 11:44:27 AM
Creation date
7/29/2020 10:30:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0523276
PE
1619
FACILITY_ID
FA0022657
FACILITY_NAME
WALMART #1554
STREET_NUMBER
3223
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12618006
CURRENT_STATUS
01
SITE_LOCATION
3223 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REACH - IN ( SELF -CONTAINED ) <br /> C V@ US ® HUSSMANN — RFL ( Innovator 1 ) — VCT RD8022 . 145 <br /> LISTED <br /> ( ': &it 107 uuJHroo+,rUAwau (III (146) <br /> low ; <br /> T M !I <br /> 1 I <br /> 41 % <br /> "I I <br /> " 7 M I I an I Ie I II _r' fiwn I I <br /> �" !1 1 m!i <br /> n r' .ii3uQ 1-1 �11. _ —_ � ) 41 Th <br /> �"" WlrlOanlbn OOINI _ (10" 43 s/1 <br /> n .. - • Um) <br /> ry 1 ' 1wr a rmma 1'-- <br /> I ", -r: p14 Front Obc1l !n • nwl <br /> � 6Door Shown I '7r ' <br /> 1 (441 <br /> 0 701/1 <br /> 76 '" Each solid end is 2 in . ( 51 mm ) ( 1711) <br /> Dimension A 8 ('7') <br /> — ., . . . I Cloaranco for Door Srinp i <br /> 3 Door 92.5 54.25 <br /> SECTION 4000r 322.88 IS 15 PLAN <br /> APPLICATION : Ice Cream <br /> AVERAGE PRODUCT TEMP (° F) 010 <br /> ENERGY DATA <br /> ENERGY DATA <br /> TDA (ft°)/ft USABLE CUBE (fP)/fl CDECO (ACTUAL) (DOEECO <br /> LIMIT) <br /> (kWh/day)/ft (kWh/day)/ft <br /> 5 .21 9. 18 2 . 86 3 . 12 <br /> REFRIGERATED CASE DATA (DX) : <br /> REFRIGERANT TYPE R404A DISCHARGE AIR <br /> CAPACITY CONVENTIONAL EVAP TEMP VELOCITY FAN SPEED SUPERHEAT AVG REF <br /> DOOR # (MBH) TEMP (°F) (°F) (fpm) (rpm) SETPOINT (°F ) CHARGE (LB) <br /> 3 3 . 27 - 19 - 12 275 1550 4-7 5 .6 <br /> 4 1 4 .36 - 19 - 12 275 1550 4-7 6. 1 <br /> ELECTRICAL DATA: <br /> FANS <br /> Innovator 1 ( 120/1 Volt) CONDENSATE LAMP TYPE (NA) HEATERS <br /> Circuit 1 PUMP <br /> ENERGY EFFICIENT ( 120/1 Volt) ANTI-SWET HEATER DRAIN HEATER DEFROST HEATER <br /> DOOR # # FANS/ EVAPORATOR FANS Circuit 1 ( CANOPY , NOSE , SHELF ) <br /> ) ( 120/1 Volt) ( 120/ 1 Voll) (208/1 Volt) <br /> TOTAL LIGHTS Circuit 1 Circuit 1 Circuit 2 <br /> AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS <br /> 3 3 0 .9 54 1 .9 87 NA NA 3.48 414 1 .25 150 10.08 2100 <br /> 4 4 1 .2 72 1 . 9 87 NA NA 4 . 57 552 2 240 13 . .46 2800 <br /> TOTAL HEAT OF CONDENSING UNIT CONDENSATE EVAPORATOR MAXIMUM OVERLOAD <br /> PAN HEATER PROTECTION DEVICE <br /> CONDENSING UNIT REJECTION (208I230V/60 Hz/ 1 Please ) <br /> DOORfl ( 120/ 1 Volt) Circuit 1 : ( 120/1 Volt) Circuit <br /> MODEL (NOTES ) Circuit t 2 : (208/ 1 Volt) <br /> BTU/HR MCA RLA LRA AMPS WATTS AMPS <br /> 3 TCLB 6300 17 . 2 11 .4 59. 2 5 600 20 , 20 <br /> 4 TCLC 1 8280 16.6 11 .4 59.2 5 600 20 20 <br /> DEFROST DATA: <br /> DEFROST TYPE DEFROSTS PER DURATION TIME TERMINATION TEMP PUMP OUT DRIP TIME TERMINATION TEMP SENSOR DEFROST WATER <br /> DAY (MIN) (°F) (MIN) (MIN) LOCATION (LB/DAY)/FT <br /> Electric 1 45 60 0 0 RH END OF COIL 6 <br /> NOTES: <br /> Energy of kWh per Day/ per foot based on shelf configuration at ice cream temperature . CE CASE <br /> Top of Case Condensing Unit Configuration LENGTH Expansion Valve Size (TXV) <br /> Case requires QTY 1 120V 20A and CITY 1 208V 20A service OR DOOR # <br /> Defrost healer and condensing unit circuits are non-concurrent loads . Circuit sized for larger of the two loads . 3 1 /2 Ton <br /> ' Condensing units are shipped separately from RFL case and field installed <br /> Case is sold and shipped as VCT . RC. L equipment class. CDEC reflects energy use per AHRI 1200 for a remote 4 1 /2 Ton <br /> configuration and does not include a field- installed condensing unit. <br /> " Working charge includes field installed condensing unit. <br /> DOE2012 R08022 , 145_REACH-IN ( SELF -CONTAINED ) <br /> Elie rgy EK icily 10/412017 <br /> Comp rant ARCH MECH ELEC REFR MECH CONSI OWNER <br /> - -- I REVIEWED REVIEWED REVIEWED REVIEWED V-APR V-APR PDSMT# 04/29/16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.