Laserfiche WebLink
SANOAQU I N Environmental Health Department <br /> COUNT -( IY <br /> Crearrie3S grows here, Time In: 10.10 am <br /> Time Out: 10:35 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: BROOKSIDE CROSSING APTS(PHASE II) Date: 07/28/2020 <br /> Address: 5301 FEATHER RIVER DR, STOCKTON 95219 <br /> Owner/Operator: BROOKSIDE CROSSING LLC Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:CPR sign is not available. Provide within 2 days. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31206) <br /> #28 Safety Vacuum Release System <br /> OBSERVATIONS:The recirculation system used to have a stingl switch, it has been disconnected.There is a vac Alert <br /> installed but it is closed and it has tape at the top.This system requires a safety vacuum release system (SVRS)because it <br /> has one main drain only. Make this svrs operable by today. Keep pool closed until the svrs is functioning. Provide photos of <br /> this system functioning or call for a reinspection. <br /> CALCODE DESCRIPTION:Public Pools with single suction outlets that are not unblockable shall be equipped with a safety vacuum <br /> release system that conforms to applicable ASME/ANSI performance standards. (CBC 31626) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 85 gpm Chlorine: 6 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: 7.6 Combined chlorine: ppm <br /> NOTES <br /> Inf 10 psi and Eff? <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: <br /> EH Specialist: VIDAL PEDRAZA Phone: (209)468-0334 <br /> FA0002879 PR0360043 SCO01 07/28/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 1 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />