Laserfiche WebLink
3.7 Description of proposed or expected maximum (including second unit dwellings) septic <br /> tank usage on site: There are no immediate plans for construction. However, each parcel is entitled <br /> to a primary residence and a second unit dwelling. Any new septic systems must be constructed <br /> under a permit. <br /> 4.0 GROUNDWATER INFORMAT W*! SECTION <br /> 4.1 Description of the depth and gradient of groundwater in the general area: The depth to <br /> ground water in this area is approximately NLS says 150-160 feet according to the map of"Lines <br /> of Equal Depth to Groundwater" published Spring, 2018, by the San Joaquin County Flood and <br /> Water Conservation District. The gradient descends from east to west. <br /> 4.2 Description/discussion of any existing and/or potential groundwater <br /> contamination issues in the general location of the site: The concerns for groundwater <br /> contamination in this area are deemed moderate due to the depths involved. Insecticides, <br /> pesticides, and fertilizers typically do not significantly impact groundwater at these depths. <br /> However, as with any agricultural area, there is always a potential for contamination due to <br /> chemicals used in the farming operation. <br /> 4.3 Description of location (address/APN),type and construction of well and location <br /> (well head/kitchen tap)where water sample(s)were obtained: Water samples were taken from <br /> a spigot at the well located on the subject property at 14953 E. Tokay Colony Road on June 16, <br /> 2020 by Mike Toy of Dillon&Murphy. <br /> 4.4. Description of constituents being tested for in the water sample: The water samples are <br /> being tested for nitrates and DBCP. <br /> 4.5 Description of how sample was obtained, handled, stored, and transported to the <br /> lab: The water samples were obtained from a spigot at the well located on the subject property at <br /> 14953 E. Tokay Colony Road. The samples were taken by Mike Toy of Dillon & Murphy, and <br /> driven directly to Precision Enviro-Tech. The samples were taken and handled in accordance with <br /> Precision Enviro-Tech requirements. The results from the test can be found in the Appendix. <br /> 4.6 Complete Chain of Custody document,including printed and signed name of third party <br /> sampler, condition of sample and date and time the sample was submitted to the lab. For <br /> Laboratory samplers, complete laboratory report to include the above noted information: <br /> The complete chain of custody document is located in the Appendix. <br /> 5.0 SOIL PROFILE INFORMATION SECTION <br /> 5.1 Site map showing the location,with dimensions, of the soil profiled pit on the parcel. See <br /> Appendix. <br /> 5.2 Description of soil profile pit including depth and dimensions. The shallow test holes <br /> were prepared per County Standards. The holes were excavated to a depth of 42 inches and 10 <br /> inches in diameter. The holes were backfilled with 2 inches of"pea gravel". <br /> 2 <br />