My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082253 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BAKER
>
16042
>
2600 - Land Use Program
>
SR0082253 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2020 11:36:52 AM
Creation date
7/29/2020 2:21:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0082253
PE
2602
FACILITY_NAME
16042 E BAKER RD
STREET_NUMBER
16042
Direction
E
STREET_NAME
BAKER
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09110008
ENTERED_DATE
6/25/2020 12:00:00 AM
SITE_LOCATION
16042 E BAKER RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.2 Description/discussion of any existing and/or potential groundwater <br /> contamination issues in the general location of the site: Description of existing or potential <br /> groundwater contamination issues in the general location of the site are referred to in Section 4.2 <br /> of the Soil Suitability Report prepared by Dillon& Murphy that is attached in the Appendix. <br /> 4.3 Description of the current use of groundwater at the site and of the future expected use <br /> of groundwater as related to the proposed development project: <br /> Based on the most recent results from San Joaquin County's "Flood Control and Water <br /> Conservation District" report on groundwater from spring 2018, the estimated depth to <br /> groundwater was determined to be 140 feet below the surface.This was verified with the California <br /> Department of Water Resource's Water Data Library. The results of the historic depth to ground <br /> water show that the relative depth has slightly dropped in recent years. The proposed <br /> improvements will not have a negative effect on the current depth to ground water as residential <br /> and agriculture use will not change. See appendix for the site's depth groundwater tables and <br /> diagrams. <br /> 5.0 SOURCES AND CALCULATED IMPACT OF NITRATE TO <br /> GROUNDWATER <br /> 5.1 Description of all current off-site sources of nitrate to soil and groundwater in the general <br /> up gradient area and the contribution of nitrate load from these sources to the project site: <br /> Current off-site source of nitrate to soil and groundwater in the general up gradient area and the <br /> contribution of nitrate loads are agriculture and neighboring sites with septic systems with minimal <br /> to no current impact to the site. <br /> 5.2 Description of impact of rainfall contribution of nitrate load to the project site: The <br /> impact of rainfall contribution on the project site was completed to determine the nitrate load. The <br /> average monthly precipitation and evotranspiration are required to calculate the site nitrate load. <br /> These two values are used to estimate the deep percolation. The deep percolation is estimated by <br /> analyzing the difference between the monthly average precipitation and the evotranspiration,when <br /> the monthly precipitation exceeds the monthly evaporation. These calculations are attached in the <br /> Appendix. <br /> The data for the potential evotranspiration water was obtained from the California Irrigation <br /> Management Information System (CIMIS). The project is located within an area designated as <br /> Zone 12. Based on the values for this area along with the average monthly precipitation values <br /> obtained from the Western regional Climate Center (Station 70) for Manteca were used as an <br /> estimate of the deep percolation of rain for the project was determined. The precipitation was <br /> determined from the City of Stockton Fire Station#4. <br /> The results for the deep percolation at the site were 3.56 in./year. The nitrate concentration is <br /> estimated to be about 1 mg/L-N. (Hantzche and Finnemore, 1992). <br /> 5.3 Description of all current on-site sources of nitrate to soil and groundwater and the <br /> contribution of nitrate load from these sources to the project site: The only source of nitrates <br /> are the existing septic system in use by an existing parcel for residential uses and agriculture use. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.