My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2231-2238 – Tiered Permitting Program
>
PR0506887
>
COMPLIANCE INFO_PRE-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2020 10:29:33 AM
Creation date
7/30/2020 7:46:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE-2016
RECORD_ID
PR0506887
PE
2233
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
02
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Supplemental fields
FilePath
\MIGRATIONS\Tiered Permitting\S\SCHULTE\14700\PR0506887\COMPLIANCE INFO PRE-2016.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS NO. 5-00-056 $ <br /> O W ENS-BROCKW AY <br /> OWENS-ILLINOIS GLASS FURNACE FACILITY <br /> SAN JOAQUIN COUNTY <br /> the present control techniques, and present the selected improved control technology. <br /> The workplan shall also include a schedule for implementation. <br /> 3. By 30 July 2000, the Discharger shall submit a comprehensive water balance analysis <br /> showing the physical changes needed to meet compliance with Discharge Specifications <br /> Nos. B.7 and B.S. Process wastewater flow rates shall be determined from those <br /> measured since April 2000, as well estimated infiltration/inflow during the rainy season. <br /> Total annual precipitation shall be based on a return period of 100 years, distributed <br /> monthly in accordance with historical rainfall patterns. If the water balance shows that <br /> insufficient pond capacity is available, then the report shall also contain a plan (design <br /> drawings) and timeline for construction of additional pond(s). Full compliance with <br /> Discharge Specifications Nos. B.7 and B.8 must be met by 1 November 2000. <br /> 4. By 30 July 2000, the Discharger shall submit a report prepared by a Registered Engineer <br /> showing that the domestic wastewater leachfields have been repaired to prevent all <br /> surfacing problems. If management changes are necessary, then the report shall describe <br /> the new practices. In addition, the report shall contain calculations to determine the <br /> maximum volume of wastewater which can safely be discharged to the leachfields. The <br /> report shall include a description of the procedure for estimating the domestic wastewater <br /> flow. <br /> 5. To determine compliance with Groundwater Limitation D.1, the Discharger shall submit <br /> a workplan for further characterization of groundwater quality by 30 July 2000. The <br /> workplan shall present an evaluation of the adequacy of the existing monitoring well <br /> network with respect to potential contaminant source areas, groundwater quality and <br /> elevation data collected to date and, historical groundwater flow directions. The <br /> workplan shall contain recommendations and a proposed time schedule for improving the <br /> monitoring well network. The workplan shall be consistent with, and include the items <br /> listed in, Attachment C, "Items to be Included in a Monitoring Well Installation <br /> Workplan and a Monitoring Well Installation Report of Results. " The Discharger shall <br /> submit a report describing the results of the groundwater monitoring well installation by <br /> 1 January 2001. <br /> 6. If process wastewater discharges to the process wastewater ponds are determined to have, <br /> or are likely to, impact groundwater quality based on the Groundwater Monitoring <br /> Summary Report or subsequent monitoring reports, then a Wastewater Treatment/Pond <br /> Mitigation Plan shall be submitted within 90 days of request by the Executive Officer. <br /> The plan shall address groundwater contaminants identified in the Groundwater <br /> Monitoring Summary Report, evaluate contaminant control alternatives, and select a <br /> preferred contaminant control alternative. The selected contaminant control alternative <br /> must comply with State Water Resources Control Board Resolution 68-16 and be <br /> consistent with the most recent Basin Plan. The Wastewater Treatment/Pond Mitigation <br /> Plan shall include future expansion considerations in the selection of the preferred <br />