My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2320
>
2300 - Underground Storage Tank Program
>
PR0231084
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 9:35:56 AM
Creation date
7/31/2020 2:14:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231084
PE
2361
FACILITY_ID
FA0006447
FACILITY_NAME
SHELL FOOD MART
STREET_NUMBER
2320
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12521030
CURRENT_STATUS
01
SITE_LOCATION
2320 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test ❑x 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10182111 9/10/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> EI Dorado Food Mart <br /> Business Site Address City ZIP Code <br /> 2320 North EI Dorado Street Stockton 95204 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Benjamin Duncan (707) 621-0378 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Afford-a-test/90-1120 5246802-UT 3/20/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number,stored product,etc.) A T-1-91 B T-2-87 C T-3-Diesel D <br /> Tank Containment <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail ❑ NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑Fail Z NA ❑ Pass ❑ Fail Z NA ❑Pass ❑ Fail ❑NA <br /> Communication Test Result ❑ Pass ❑Fail E NA ❑ Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑ Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail ❑NA <br /> Communication Test Result ❑ Pass ❑Fail E NA ❑ Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA Z Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑ Pass ❑Fail ENA ❑ Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑ Fail ❑NA <br /> UDC ID: 1 1&2 2 3&4 3 5&6 4 7&8 <br /> Tightness Test Result E Pass ❑Fail ❑ NA E Pass ❑Fail ❑ NA E Pass ❑ Fail ❑NA Z Pass ❑ Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑NA ❑ Pass ❑ Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑Fail ❑ NA ❑ Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑NA ❑Pass ❑ Fail ❑NA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23, Division <br /> 3, Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br />