Laserfiche WebLink
Sn N J o A Q r I I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : TAugust <br /> te : <br /> UNITED # 5447 1469 E HAMMER LN ; STOCKTON 06 , 2019 <br /> UST System Observations <br /> 313 HSC 25290. 11 25290. 2 , Failure to construct, operate , and maintain primary containment as product-tight V R COS <br /> 25291 <br /> 314 HSC 25290. 1 , 25290. 2 , Failed to have secondary containment or secondary containment not tight V R - COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003 ) V R = COS <br /> 316 HSC 25290. 1 (c3) , Secondary containment not constructed to prevent water intrusion (after Jul 2003 ) _ V _: R COS <br /> 25290 . 2 (c3) <br /> 317 CCR 2636 , 2643(c) ( 1 ) , Line leak detector ( LLD) not installed -: V = R - COS <br /> 2666(f) <br /> 318 CCR 2666 (c) , 2643(c) Leak detector failed to detect a 3 . 0 gallons per hour leak at 10 pounds per square inch V R ■ COS <br /> 319 CCR 2635 , 2637. 11 No spill bucket, failed to contain 5 gallons ,0 means to keep it empty, or failed to be tested V R c COS <br /> 2665 , 2712 S c 1 6 rh 1 0tZ , .L- jy 02 ,,e -1 /h , 2 <br /> 320 CCR 2635, 2637, 2t Failure to comply with the installation , inspection , or record keeping of the overfill prevention V R _ COS <br /> 2665 , 2712 !'U ;,.t / 1 f 'e CZ e _ _ / e <br /> 321 CCR 2635(b) (2) Overfill prevention was overridden V ❑ R , COS <br /> 322 HSC 25281 . 6(a ) Unburied below grade emergency generator system failed to meet exemption status V R COS <br /> 323 HSC 25283. 5(a) Unburied below grade UST system failed to meet exemption status V R COS <br /> 324 CCR 2717 . 1 (g ) Tampered with red tag _ V R ❑ COS <br /> 325 CCR 2717A (f) Deposited petroleum into a red tagged UST : V R COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms V R COS <br /> 327 CCR 2631 , 1 , 2660 (m) UST system not compatible with the substance stored V o R COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements V R = COS <br /> 329 HSC 25298 ; CCR 2670, Failed to comply with all permanent closure requirements _ V R COS <br /> 2672 <br /> 330 CCR 2636 (012666 ( c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm V , R = COS <br /> 2666 (f) <br /> 331 CCR 2630(d) , 2641 (a) Liquid does not flow into the sump in the event of a leak ( i . e . , failure to remove test boot) . V ❑ R o COS <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards V R L: COS <br /> 2666(b &e) <br /> 333 CCR 2635 , 2636 (b) , Failure to comply with the cathodic protection system requirements , V ❑ R a COS <br /> 2662 , 2712 <br /> 334 CCR 2666(b) (2 ) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair 7 V ❑ R o COS <br /> 335 CCR 2630 , 2632 , 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third -party V 77 R ^ COS <br /> 2644. 1 <br /> Single -Wailed Non-Pressurized Piping <br /> 401 CCR 2636(a) (3) , Suction piping not properly sloped or incorrectly located check valve _ V R = COS <br /> 2641 ( b) <br /> 402 CCR 2643 (d ) No monitoring or record maintenance for single-walled conventional suction systems ( pre-Jan 1984 ) . -: V - R c COS <br /> 403 CCR 2643(d ) , 2661 (f) Failure to conduct 0 . 1 gph test for single-walled conventional suction systems (pre-Jan 1984 ) _ v R = COS <br /> 404 CCR 2643 (e ) , 2661 (0 Biennial 0 . 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) V ❑ R _ COS <br /> Other Violations <br /> FA0001570 PR0231126 SCO01 08/06/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 3 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468 -3420 F 209 464 -0138 1 www. sjcelid . com <br />