Laserfiche WebLink
SAN ) O A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> UNITED # 5447 1469 E HAMMER LN , STOCKTON August 06 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> ( CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 319 CCR 2635 , 2637 . 11 26651 2712 No spill bucket , failed to contain 5 gallons , no means to keep it empty, or failed to <br /> be tested . <br /> The 87 product and Diesel product direct bury spill bucket failed when tested . All USTs shall be equipped with a spill <br /> container that has a minimum capacity of five gallons and a drain valve that allows drainage of the collected spill into <br /> the primary container or provide a means to keep the container empty . Immediately contact a properly licensed , <br /> trained , and certified contractor to install an approved spill container under permit and inspection of the EHD . If a spill <br /> container can ' t be installed immediately, there is a possibility that the 91 UST system may be red tagged to prevent <br /> fuel inputs . G- /2s iv , / / S ,4 h .47 . A pep m . �1 ,�� /, < v, , . �A54zv0 ICE:; <br /> This is a minor violation. ' <br /> 320 CCR 26351 2637 . 21 26651 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> Overfill prevention testing has not been conducted . This testing was required to be conducted by October 13 , 2018 . <br /> Immediately schedule this testing and provide 48 hours notification to the EHD . Ensure all future testing is conducted <br /> within required time frames D !/ t„2 IC, // -7- .e5A1;119 Ie <br /> This is a Class II violation. <br /> Overall Inspection Comments , <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , by September 5 , 2019 . <br /> Starting September 1 , 2018 , all in - office CERS help will be provided at EHD hourly rate ($ 152 ) . To schedule an <br /> appointment , please call (209 ) 468 -3420 . <br /> Documents provided : Retrurn to Compliance Certification Form and a list of free scheduled CUPA classes . <br /> AFTER THE COMPLIANCE DATE , EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE . <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD ' S CURRENT HOURLY RATE . <br /> Received by : Date : <br /> August 06 , 2019 Inspector : Inspector Phone : <br /> Printed Name and Title: PAUL NSO , EHS Trainee ( 209 ) 468-3432 <br /> Janene Asuncion , Manager <br /> FA0001570 PR0231126 SCO01 06/06/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 - 3420 F 209 464 -0138 1 www . sjcehd . com <br />