My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0504967
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2021 12:00:12 PM
Creation date
7/31/2020 3:00:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0504967
PE
2361
FACILITY_ID
FA0006440
FACILITY_NAME
SHERIFFS OPERATIONS CTR #2
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
BLVD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
if the facirty has rjnii:omponents than this form accommodates, additional copies of this page maybe attached. <br />CERS =California Environmental Reporting Systeny ID = Identificatio»,USI'= Underground storage tank, ICC = Lrten�ational Code Council, A/V = Audible vid visual <br />UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action ❑Installation Inspection ❑Repair Inspection ®36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID <br />Date of Overfill Prevention Equipment Inspection <br />10182105 <br />10/11 /2018 <br />Business Name (Same as Facility Name or DBA -Doing Business As.) <br />San Joaquin County Sheriffs Operations Ctr #2 (Facilities Management/Jail) <br />Business Site Address City <br />ZIP Code <br />7000 N. Michael Canlis Blvd French Camp <br />95231 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) <br />Phone # <br />Eric Mol acrd <br />209 367 - 4800 Ext. <br />Contractor/Tank Tester License # <br />ICC Certification # <br />ICC Certification Expiration Date <br />774802 <br />8881020 <br />02/25/2019 <br />Ove�ll Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />OPW UST AST <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method Used: ❑Manufacturer Guidelines (Specify) <br />® Industry Code or Engineering Standard (Specify) PEI/RP1200-17 <br />❑ Engineered Method (Specify) <br />Attach the inspection procedures and all documentation required to determine the results. <br /># of Attached Pages: 6 <br />Tank ID: (By tank number, stored product, etc.) <br />968-20k-dsl <br />969-15k-dsl <br />What is the tank inside diameter? (Inches) <br />119 <br />119 <br />Is the fill piping secondarily contained? <br />❑Yes ®No <br />❑Yes ®No <br />❑Yes ❑ No <br />❑Yes ❑ No <br />Is the vent piping secondarily contained? <br />❑Yes ®No <br />❑Yes ®No <br />❑Yes ❑ No <br />❑Yes ❑ No <br />OPW <br />OPW <br />Overfill Prevention Equipment Manufacturers) <br />®Shuts Off Flow <br />®Shuts Off Flow <br />❑Shuts Off Flow <br />❑Shuts Off Flow <br />What is the overfill prevention equipment <br />response when activated? <br />❑Restricts Flow <br />❑Restricts Flow <br />❑Restricts Flow <br />❑Restricts Flow <br />(Check all that apply.) <br />❑ AN Alarm <br />❑ A/V Alarm <br />❑ A/V Alarm <br />❑ A/V Alarm <br />Are flow restrictors installed on vent piping? <br />❑Yes ®No <br />❑Yes ®No <br />❑Yes ❑ No <br />❑Yes ❑ No <br />At what level in the tank is the overfill prevention <br />106 <br />106 <br />set to activate? (Inches from bottom of tank.) <br />What is the percent capacity of the tank at which <br />95 <br />94 <br />the overfill prevention equipment activates? <br />Is the overfill prevention in proper operating <br />®Yes <br />®Yes <br />❑Yes <br />❑Yes <br />condition to respond when the substance <br />❑ No <br />❑ No <br />❑ No <br />❑ No <br />reaches the appropriate level? <br />(Specify in section V.) <br />(Specify in section V.) <br />(Specify in section V.) <br />(Specify in section V.) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results <br />®Pass ❑ Fail <br />®Pass ❑Fail <br />❑Pass ❑Fail <br />❑Pass ❑Fail <br />V. COMMENTS <br />All items marked "Fail" must be explained in this section. Any additional comments may also be provides! ��re� ; 3 ; f ,y � `� �� <br />{ 4i ;2 � -� 4 <br />,^ v <br />n� ... <br />`.I( )( <br />._ „ <br />sr, 3 <br />�� ,� �•�����u� ���.�"; ��_i_ ����° � ad �k ��� <br />��..-� . <br />tit <br />F „ -.e � ) � � f <br />�i S � <br />� <br />.. <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br />chapter 16, section 2637.2 and all t i formation contained herein is accurate. <br />UST Service Technicia igrr" <br />a.--� <br />if the facirty has rjnii:omponents than this form accommodates, additional copies of this page maybe attached. <br />CERS =California Environmental Reporting Systeny ID = Identificatio»,USI'= Underground storage tank, ICC = Lrten�ational Code Council, A/V = Audible vid visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.