My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2494
>
2300 - Underground Storage Tank Program
>
PR0231104
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:11:27 PM
Creation date
7/31/2020 3:55:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231104
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003863
FACILITY_NAME
SOHAL #3
STREET_NUMBER
2494
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15328008
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
2494 E FREMONT ST STOCKTON 95205
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN" J D�l+ �� I 1411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SOHAL#3 1 2494 E FREMONT ST STOCKTON June 28 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed to document all the alarms from the attached alarm history on the designated operator <br /> inspection reports and failed to check that they were responded to appropriately. Numerous alarms occurred on the <br /> UST system prior to a tank top upgrade being conducted in 2018. During the inspection,the designated operator shall <br /> review the alarm history since the previous inspection, check that each alarm was documented and responded to <br /> appropriately, and attach a copy of the alarm history with documentation taken in response to any alarms to the <br /> report. Ensure that designated operators performing inspections at this facility are including all of the required <br /> information on the reports. <br /> The designated operator failed to visually inspect the sumps for leaks,water, or debris during inspections during 2018; <br /> numerous alarms occurred in the sumps during this time while the site was waiting for repairs and a tank top upgrade. <br /> The designated operator noted numerous repeat alarms from month to month, but did not document sump <br /> inspections. During the inspection,the designated operator shall visually inspect all spill containers and UDC sumps, <br /> and any tank top sump that had an alarm for which there is no record of a service visit. Ensure that designated <br /> operators performing inspections at this facility are inspecting all of the required areas and noting it on the on the <br /> reports. <br /> The designated operator failed to check and note all required items on the visual inspection reports.The incorrect and <br /> missing information included the following from the inspection reports: <br /> -Section V was left blank. <br /> -Section III was left blank. <br /> -The question regarding UDC sensor locations was left blank. <br /> -Section V is being completed by the designated operator with infomraiton regarding the issues found. This section is <br /> to be completed by the owner/operator with a description of corrective actions taken in response to the issues listed in <br /> Section III. <br /> -Alarm histories were not attached to the 2/25/19 and 3/26/19 inspection reports. <br /> -The alarm history attached to the 12/24/18 report did not contain S alarms. <br /> -The 10/29/18 report was written on an outdated inspection form. <br /> -The No and NA responses are not documented in Section III. <br /> -The designated operator is incorrectly marking that all issues from previous inspections were properly followed up to <br /> even when listing repeat issues. <br /> During the visual inspection,the designated operator shall check that all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designated operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> A designated operator inspection for the following months was performed more than 30 days: <br /> -Conducted 11/23/18, next conducted 12/24/18 (31 days) <br /> -Conducted 12/24/18, next conducted 1/25/19(32 days) <br /> -Conducted 1/25/19, next conducted 2/25/19(31 days) <br /> The designated operator visual inspections shall be conducted within 30 days or less of the previous inspection. <br /> Ensure that all designated operator inspections are performed within the required time frames. <br /> FA0003863 PR0231104 SCO01 06/28/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.