11" <br /> 1`-7" EMERGENCY SWITCH PARTS AND SIGN <br /> 10 10 SUPPLIED BY 7-ELEVEN, INC.AND <br /> 0 a VERTICAL SEALING INSTALLED BY GAS CONTRACTOR <br /> c <br /> RIGID CONDUIT <br /> 0°0°0°0°0°0°0°0°0°o c <br /> 0°0°0°0°0°0°0°0°0°0 1'-0" <br /> 0 0 0 0 0 0 0 0 0 EYS CONDUIT <br /> MagVFC °0 °0°°00000000000 SEALING COMPOUND USE COMPOUND SEAL FITTING XP Q <br /> °o°0°000°n°0°n°0°0° MADE BY MANUFACTURER OF SEAL { , <br /> FITTING <br /> SIGN <br /> (WHITE WI RED pEMERGENCY� <br /> LETTERING) SHUT OFF G>' <br /> PUSH CONDUCTORS AWAY FROM THE FILLING e SWITCH <br /> OPENING&FORCE THEM APART SO THEY DO N <br /> NOT LIE IN CONTACT WITH EACH OTHER ALONG PACKED FIBER Q <br /> cv THEIR LENGTH PUSH SHREDS OF PACKING DAM COVER <br /> AWAY FROM THE CONDUCTOR TO PREVENT (SAFETY TECHNOLOGY <br /> 000000000 GAS LEAKAGE PATHS INTERNATIONAL, INC. #k <br /> 000000 NOTE: u <br /> Proto 11-05-18 <br /> °00000 LARGE MUSHROOM HEAD Z_ <br /> 0°0°00 PROVIDE EXPLOSION PROOF SEALS. 1N ACCORDANCE WITH ARTICLE 501, CLASS 1, EMERGENCY STOP BUTTON <br /> 000000 DIVISION 2 OF THE LATEST NATIONAL ELECTRICAL CODE TYPICAL FOR ALL (CONTACT ACTUATOR) CL <br /> UNDERGROUND CONDUIT STUB-UPS INTO EQUIPMENT �� � 0 0� <br /> � O <br /> 0 Q SEAL OFF ALL CONDUIT ENTERING OR LEAVING CAVITIES OR ENCLOSURES OF <br /> DISPENSERS AND ASSOCIATED EQUIPMENT. IN ADDITION,ALL CONDUITS COMING co O <br /> FRONT VIEW SIDE VIEW FROM THE BUILDING THROUGH A HAZARDOUS LOCATION ALSO REQUIRE <br /> SEAL-OFFS AT BOTH ENDS. rn " <br /> U- co Q <br /> FE PETRO MAGVFC-VARIABLE <br /> Lu <br /> FREQUENCY CONTROLLER. SEE MANUAL U C)o <br /> FOR WIRING INSTRUCTIONS. z (�V (� <br /> _ j M rn W <br /> Z ZU W J <br /> MAG 1/EC DETAIL. SEAL FITTING INSTALLATION EMERGENCY SHUT OFF W COVER w 4 LLJ <br /> z -jo = W <br /> 4 NTS 3 NTS 2 NTS W � > O ❑ <br /> J >- WZU z <br /> W w JoO <br /> � m <br /> W "} w <br /> � U <br /> Q I) <br /> s � <br /> 0 <br /> 0 <br /> cn <br /> EMT CONDUIT a <br /> SIZE AND QUANTITY OF CONDUITS <br /> co ARE FOR REFERENCE ONLY. <br /> W <br /> O <br /> I � <br /> ELECTRICAL ROOM CEILING <br /> (ACTUAL LAYOUT MAY VARY I <br /> TO MEET SITE CONDITIONS) <br /> W <br /> STORE CONTRACTOR: <br /> INSTALL CONDUIT FROM THE ELECTRICAL <br /> ROOM TO 10'-0" PAST BUILDING SLAB. SEE EMS I <br /> SPECIFICATION SHEET G16.0, SECTION VII, MAG MAG <br /> 2.3.1 FOR CONDUIT TYPES. VFC VFC CP-1Lu <br /> ® a <br /> FUELING CONTRACTOR: I w <br /> EXTEND CONDUITS FROM 10'-0" PAST THE STP 0 � I z s <br /> BUILDING SLAB TO FINAL TERMINATION 3 POLE 100 AMP CBS o <br /> POINT. SEE SPECIFICATION SHEET G16.0, <br /> LLJ W <br /> CONTACTOR <br /> ZSECTION VII,2.3.1 FOR CONDUIT TYPES. p <br /> 00 <br /> W w a> <br /> I I wa.� z og <br /> O � J 0) <br /> - U 2 <br /> I TO SALES I W tic W I N <br /> WIRE WAY COUNTER <br /> Ir <br /> SUPPLIED BY Flo <br /> a <br /> REF STORE 7-ELEVEN <br /> E1.1 SHEET STORE I NEW 1 <br /> FOR PANEL PANEL PANEL <br /> INFORMATION F r Q 0) <br /> C7 = <br /> IDBOX I LLI T_o z H <br /> STP CD <br /> IR 1U Q z N <br /> TYP 3 i <br /> ii co m <br /> cj] <br /> I _ I C ,C <br /> STP STP <br /> IR IR 0 O V <br /> E I I � u) ❑ ❑ U <br /> 1 <br /> . C C == N <br /> t N 0 m' D rrt 0 03 3 w <br /> c -4ai `zo <br /> � 0'kca� axi� o°�, <br /> WIRE WAY <br /> E L <br /> WIRE WAY WIRE WAY WIRE WAY WIRE WAY -0.2 e. o ! o , , , <br /> a I I a) a <br /> Q-° 3 a=µ-ms, 3.' <br /> Q.��� co f amic'ca <br /> � oocu .5 � <br /> c� � y � ai3N � �—© E <br /> NS �yY C 7+-- <br /> a�ic� m <br /> C040 E'o <br /> _ FLOOR o (D >,a)"a0F Em <br /> � p � <br /> 1= <br /> ❑ C � i� (DB °0��E <br /> Z Q ° <br /> U T 0 Q 0 ¢ L) <br /> ix <br /> i Q a0. z ry w �OFESSI <br /> d ¢ Cwm _j7 w `' w IL co uj U) z rt�. W - <br /> < LLk <br /> z a w T ' <br /> 'Q Q j CL cow <br /> LHis �' ° o n w 35558 ;o <br /> 0 D <br /> l� FCHANWO Q� <br /> OF CAW-WFO <br /> C=!c::, <br /> POWERZDATA EQUIPMENT DETAILS E NTS SHEET: 12118/19 <br /> 3 <br /> G10 . 0 <br /> FUELING - USA <br />