C",2LENGTH OF WELD <br /> = - <br /> BEAM HEIGHT +1" 3/16 <br /> —14XJ" TYP T&B HEADER <br /> —14Xj" HWH TEK ® BEAM BEAM <br /> HWH TEK SCREW ® 32" 3/16 <br /> SCREW @ 32" O.C. MAX FLANGE U' <br /> O.C. MAX -14xg" (4) J"O A307 BOLTS D <br /> 4-14x " HWH TEK <br /> HWH TEK MTL CORNICE SCREW <br /> MTL CORNICE SCREW <br /> (TYP., U N Q ) (TYP., U.N.O.) STD HOLE GAGES <br /> 13"x1J" 20ga FLANGE WIDTH HOLE GAGE C <br /> CEE FRAME 48" " STIFFENER C U <br /> 3„ 4" 2 „ <br /> 3» PINES BOTH <br /> 1 "x18" 2pga CEE 2„ O.C. MAX. 5" - 6 " SIDES " <br /> 2„ FRAME ® 48" 5„ 6" <br /> 5" O.G. MAX. <br /> 2 ACM 1 ASCIA 2" I <br /> ACM FASCIA 12-14x " <br /> HWH TEKS/3 TYP �8 1 3/4" X 12" X 19" <br /> SCREWS (TYP. <br /> G I CAP PLATE <br /> FRAME TO DECK) I D UD <br /> UD <br /> 36" I I c�z <br /> 36" 19" <br /> 20GA X 1j" ZEE 12" 12` <br /> 45° <br /> 20GA X 1j" ZEE 1 PER ACM I <br /> 1 PER ACM PANEL ' COLUMN 0 <br /> ( Z _j w <br /> I I I cn <br /> PANEL I I TYP 1/g I O Q d <br /> 1/8 p I I F- w <br /> 55„ <br /> 5" 12" O I I <br /> U <br /> 12-14xi" 3"x 16 x20ga O I I 456 I I U <br /> HWH TEKS/3 3"X16"X20ga PAN DECK <br /> P.H. SCREWS (TYP. PAN DECK #8XJ" P.H. 20 a w U� <br /> #8X� FRAME TO DECK) SCREW ® 32" $" 9 � � � <br /> SCREW 0 32" 8" Q.C. MAX PERIMETER <br /> C-C. MAX 20ga GUTTER SECTION C — C SECTION D — D <br /> O a O <br /> Z O <br /> PERIMETER Z ~ <br /> GUTTER U cn <br /> CC� L�JMN/ BEAM CONNECTION DETA L <br /> IDE FASCIA DETAIL � END FASC A DETAIL 3 SCALE: 1"w1'—a" <br /> 1 ALE: 1"=1'-0" <br /> z 00 <br /> O <br /> PURLIN BEAM HEADER BEAM <br /> zOO <br /> DECK PURLIN SEAM HEADER BERM U <br /> STIFFENER PLATE O j C) <br /> 1/4 NOTES: w O <br /> HEADER R (N.S. & F.S.) DECK <br /> BEAM <br /> FASCIA A. CONDUIT WITH PLAIN THREADED END 0 w Z V) <br /> OWNER OPTIONS: FASC#A FURNISHED AND INSTALLED BY JIMCO. o <br /> HEADER PERIMETER ( CUSTOMER TO INFORM ELECTRICAL WIRING AND HOOK-UP BY <br /> 4 A307 BOLTS -IyP 3/16 BEAM GUTTER JIMCO OF DIRECTION OF DRAIN GENERAL CONTRACTOR. <br /> ( ) � DISCHARGE AT LEAST TWO WEEKS c B. COUPLING AND CONDUIT TO CANOPY <br /> Q EACH CONNECTION T gt 8 3/16 SEE NOTE B SEE NOTE A LIGHTS FURNISHED AND INSTALLED BY <br /> PURLIN PRIOR TO SCHEDULED DELIVERY): PERIMETER <br /> BEAM GUTTER GENERAL CONTRACTOR. <br /> 3" P.V.C. C. COUPLING AND CONDUIT TO POWER <br /> Bh+1 GUTTER LEADER 1 .) DRAIN BELOW GROUND. COLUMN SUPPLY FURNISHED AND INSTALLED BY <br /> (4) A307 BOLTS 3/16 <br /> ® EACH CONNECTION RIGID GALV. CONDUIT GENERAL CONTRACTOR. <br /> U 20 GA. X 7" WIDE D. CUSTOMER TO INFORM JIMCO WHICH <br /> * Bh = BEAM HEIGHT GUTTER LEADER COVER NOTE: JIMCO SHALL FURNISH AND GALV. SEAL OFF COLUMNS ARE TO RECIEVE CONDUITS pEJL� <br /> 3" INTO 4" P.V.C. INSTALL CANOPY DRAINS. AND WHICH DIRECTION CONDUITS <br /> 6"X8" HAND HOLE ENTER COLUMNS 0 BASE AT LEAST a <br /> PANEL CLIP ® 16" O.C. W X7"XO" COVER PLATE TWO WEEKS PRIOR TO SCHEDULED C68927 <br /> / "- - DELIVERY. <br /> STAGGERED EACH SIDE W/(4) 12-24X1REWS 4'-p t6 �aAe Lalonde b��, <br /> _-.� ----_—_ - -- - PURLIN OF PURLIN BEAM COUMN HWH TEKS 5 SCREWS P HippeLalalda <br /> BEAM TOP OF PAVING :2019-12.19 <br /> TOP OF PAVING OR ISLAND 1 6:55-06'00' <br /> Z <br /> NOTE: 12/19/19 <br /> 4" GAP <br /> CUSTOMER REQUEST: <br /> FOOTING FOOTING (4) 1 " CONDUIT <br /> W/SEAL-OFF <br /> 3"x16"x20ga SEE NOTE C SEE NOTE A m <br /> PAN DECK SIDE VIEW <br /> w <br /> INTERNA��C ONDUIT DETAIL�Sc <br /> AM CONOLUMN DRAIN DETAIL �A SCALE: 3 =1 - V) <br /> BEAM — S P L!C E DETAIL SCALE: 3"=1 ' a" <br /> LE: -0" <br /> SCALE. 1 1 a w <br /> Ci. <br /> U <br /> I V) <br /> U Z <br /> Z O <br /> U) <br /> PERIMETER <br /> w L>i..i <br /> GUTTER w Of <br /> J <br /> w <br /> FRAMEWORK I <br /> 22" � <br /> FASCIA DECK (TYP) <br /> z <br /> 16" 1 1/2"o O <br /> II o `� (NP) HOLE rz 0- <br /> STEEL W <br /> �} COLUMN o <br /> 2 7 I (2) TEKS 5 SCRE�WSWPER � <br /> 2 HWH F__ w <br /> CONNECTION D <br /> v o <br /> VI <br /> z <br /> PERIMETER <br /> GUTTER 1/2 I 1 <br /> 3" DRAIN OUTLET LEADER <br /> COVER <br /> 3" FLEX COUPLING W/(2) <br /> o <br /> W/(2) CLAMPS PERIMETER GUTTER <br /> Lb �- <br /> � <br /> 2" X 4" CUT--OUT m _j w <br /> 3" PVC TO COLUMN Q SIDE OF GUTTER <br /> 1 1/4"X22"X22" <br /> SCUPPER COVER L2" X 2" XJ" BASF PLATE � = N a <br /> LEADER CONNECT ON DETAIL BRIDGING n r <br /> SCALE: 1 <br /> PURLIN JOB NO. <br /> f 1�j I � n I © RIDGING DETAIL (� BASE PLATE DETAIL 19-�--4080RO <br /> NO <br /> T1ICE: THIS DOCUMENT IS THE PROPERTY OF JIMCO SALES & MFG. NEITHER THIS F�0 ��1 SC � P PER DETAIL C� PVI \ �I I v u `' SCALE: 1"-1'-0" <br /> DOCUMENT NOR ANY DATA OR INFORMATION HEREIN SHALL BE COPIED OR SCALE: -0" SCALE: DWG. <br /> REPRODUCED IN ANY MANNER, LOANED OR OTHERWISE DISPOSED OF, OR USED <br /> CS <br /> FOR ANY PURPOSE WHATSOEVER, WITHOUT THE PRIOR WRITTEN PERMISSION <br /> OF JIMCO SALES & MFG. IF THIS DOCUMENT IS LOANED BY OR WITH THE <br /> AUTHORITY OF JIMCO SALES & MFG, THE BORROWER, INCONSIDERATION OF SUCH OF 2 SHEETS <br /> LOAN, ARI=ES TO THE FOREGOING CONDITIONS AND TO RETURN THIS DOCUMENT ON <br /> REQUEST OR UPON COMPLETION OF THE SPECIFICALLY AUTHORIZED WORK FOR <br /> WHICH IT WAS USED. <br />