Laserfiche WebLink
LG 162-2 3 - <br /> 4. Has the definition of " pipe" changed for USTs installed on or after July 1 , <br /> 2003? <br /> Yes . Vent piping , vapor recovery piping , and fill pipes that are beneath the <br /> surface of the ground and installed in conjunction with a UST system on or after <br /> July 1 , 2003 are regulated "pipe" and are subject to secondary containment <br /> requirements . [H &S Code , §25290 . 20) .] <br /> 5. Are the piping exemptions provided in H &S Code, Section 25281 .5(a) (4) and <br /> ( b)( 1 ) , and the secondary containment exemptions in Section 2636 (a) , Title <br /> 23 , CCR applicable to USTs installed on or after July 1 , 2003? <br /> No . The piping exemptions provided in H &S Code , Section 25281 . 5 (a) (4) and <br /> (b) ( 1 ) , are not applicable for UST systems installed on or after July 1 , 2003 . <br /> [H &S Code , §25290 . 20 ) .] Additionally , the secondary containment exemptions <br /> (for vent and tank riser piping , vapor recovery piping , and safe suction piping) in <br /> Section 2636 (a) , Title 23 , CCR are not applicable for USTs installed on or after <br /> July 1 , 2003 . There are no exemptions from the secondary containment <br /> requirement for USTs installed on or after July 1 , 2003 , <br /> 6 . What type of post-installation testing is required for USTs installed on or <br /> after July 1 , 2003, and when should the testing be completed ? <br /> The UST must be tested after installation , and before it is placed into use , using <br /> one of the following three test methods : ( 1 ) enhanced leak detection ( ELD) , (2) <br /> an inert gas pressure test certified by a third-party and approved by the State <br /> Water Board , or (3) a test method deemed equivalent to ELD and approved by <br /> the State Water Board in regulation . [H &S Code , §25290 . 2(i) .] <br /> As of the date of this letter, three tests have been determined to meet the ELD <br /> performance criteria and are allowable for post-installation testing : <br /> Vendor Test Method <br /> Praxair Services , Inc. Enhanced Tracer Tight° <br /> iota° VaporTite - V005 and <br /> CGRS , Inc. Enhanced Tracer Tight® <br /> Leak Detection Technologies , Inc MD Leak <br /> The three ELD test methods can be used when there is no fuel in the system . <br /> The Enhanced Tracer Tight® test and the MD Leak test may also be conducted <br /> with fuel in the UST. To conduct either test with fuel , the owner or operator <br /> should first obtain approval from the local agency to have fuel delivered to the <br /> UST. Prior to approving a fuel delivery , the local agency may need to verify that <br /> all pertinent installation requirements have been met. A UST system should not <br /> be put into service until the facility has been issued a valid operating permit by <br /> the local agency. <br /> California Environmental Protection Agency <br /> CO Recycled Paper <br />