My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
2300 - Underground Storage Tank Program
>
PR0545645
>
INSTALL_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:44:03 AM
Creation date
8/3/2020 12:07:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2020
RECORD_ID
PR0545645
PE
2351
FACILITY_ID
FA0025876
FACILITY_NAME
7 ELEVEN INC #38877
STREET_NUMBER
1515
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15904026
CURRENT_STATUS
01
SITE_LOCATION
1515 E MAIN ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 162-2 . 5 - <br /> 25290 . 2(d ) <br /> 5 -25290 . 2(d ) include , but are not limited to , riser piping and access points on top of <br /> the tank , which provide access to the primary containment of the tank and may <br /> be in contact with vapors of the stored product. <br /> 10 . For USTs installed on or after July 1 , 2003 and prior to July 1 , 2004, is an <br /> annual line tightness test on pressurized piping required ? <br /> Yes . As for all USTs installed since January 1 , 1984 , the requirement for <br /> " underground pressurized piping . . . (to) be tightness tested annually" also applies <br /> to USTs installed on or after July 1 , 2003 and prior to July 1 , 2004 . [H &S Code , <br /> §25290 . 2(g) ; H &S Code , §25291 (f) .] The annual line tightness testing requirement <br /> may be met by satisfying the criteria specified in CCR , Title 23 , Section 2636 (g) ( 1 - <br /> 5) , <br /> PART II : USTs INSTALLED ON OR AFTER JULY 1 , 2004. <br /> In addition to the requirements discussed below (Questions A-D of Part 11 ) , USTs <br /> installed on or after July 1 , 2004 are subject to all of the installation and monitoring <br /> requirements presented in the responses to Questions 1 -8 of Part I . For USTs installed <br /> on or after July 1 , 2004 , references to the "July 1 , 2003" date in Part I should be <br /> substituted with "July 1 , 2004 . " The H &S Code citations relevant to USTs installed on or <br /> after July 1 , 2003 and July 1 , 2004 are provided in the table below. Note that Questions <br /> 9 and 10 of Part I do not apply to USTs installed on or after July 1 , 2004 . <br /> H &S Code Citation for USTs H &S Code Citation <br /> Installed On or After July 1 , 2003 and for USTs Installed <br /> Question Prior to July 1 , 2004 On or After July 1 , 2004 <br /> Number Part 1 Part 11 <br /> 1 H &S Code §25290 . 2 a H &S Code 25290 . 1 (a <br /> 2 <br /> 3 H &S Code §25290 ,2 (c) (3) H &S Code 25290 . 1 (c)(3) <br /> 4 H &S Code §25290 .20) H &S Code §25290 . 1 (k <br /> 5 H &S Code 25290 . 2 H &S Code 25290 . 1 k <br /> 6 H &S Code §25290 .2 (i) _ H &S Code 25290 . 1 <br /> 7 H &S Code 25290 . 2 H &S Code 25290 . 1 <br /> 8 H &S Code §25290 . 2 H &S Code §25290 . 1 <br /> A. In accordance with H &S Code, Section 25290 . 1 (e) , which components of <br /> USTs installed on or after July 1 , 2004 must be continuously monitored <br /> using vacuum , pressure , or interstitial liquid level measurement methods ? <br /> The interstitial space of the tank and product piping (including fill , vent , and vapor <br /> recovery piping) , that are beneath the surface of the ground must be maintained <br /> under constant vacuum or pressure . Statute also requires that a breach in the <br /> primary or secondary containment be detected before the liquid or vapor of the <br /> stored substance is released to the environment. Continuous vacuum , pressure , <br /> or interstitial liquid level measurement methods can be used to satisfy these <br /> California Environmental Protection Agency <br /> Ot Recycled Paper <br />
The URL can be used to link to this page
Your browser does not support the video tag.