My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
401
>
4200 – Liquid Waste Program
>
PR0526172
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2020 7:50:28 PM
Creation date
8/5/2020 10:00:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200 – Liquid Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526172
PE
4242
FACILITY_ID
FA0017710
FACILITY_NAME
ANKA NORTHSTAR
STREET_NUMBER
401
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
MANTECA
Zip
95336
APN
24130052
CURRENT_STATUS
01
SITE_LOCATION
401 S AIRPORT WAY
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\4200 - Liquid Waste\A\AIRPORT WAY\401\PR0526172\INSPECT CORRESPOND.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIAL ORDER TANKS CAST <br /> t? <br /> WITH INLETS AND OUTLETS ADVANTEX <br /> SET LEVEL z w c? o <br /> AX20 POD r <br /> w � z w C <br /> o <br /> w <br /> IN FROM U Z a Lor z o -U <br /> FLOW MM3U RECIRCULATION MAX. 1'-0„ z z c <br /> SPLITTER RISER & LID VALVE —RISER &LID BELOW SURFACE O Z 0 w <br /> VENT <br /> O j O b- O," O � <br /> C7 LU w C� n- CLA <br /> O O <br /> ._.�- <br /> _ L-I ! -' <br /> 2-6 MIN. SOIL COVER I <br /> +� w , T <br /> I- _; I _II <br /> —..l� <br /> IN, SOIL COVER � � � I-- � O <br /> FLOW SPLITTER <br /> NOT SHOWN Q vQi <br /> .._,� _.....m.. - <br /> .,.E <br /> I <br /> LU <br /> NOTE <br /> - — FLOAT RECI CULATION,AND ❑ U <br /> INLET = LIQUID LEVEL - PANEL SET INGS TO BE —� I E '^� O <br /> — LIQUID LEVEL = L <br /> LIQUID LEVEL PERFORMS BY ENGINEER <br /> DURING INS ECITION <br /> • w > . . . <br /> J O ¢ V Q 1 o <br /> wQ � � 0? <br /> O � o6�- <br /> -' J C) Jori <br /> DUPLEX PUMPING z O 0 U Z o <br /> PRIMARY SEPTIC TANK PRIMARY SEPTIC TANK RECIRCULATING TANK PUMPING ASSEMBLY — <br /> ASSEMBLY Z Q 0 0 O0 <br /> 1,500 GAL. P&L MONOLITHIC TANK 1,500 GAL. P&L MONOLITHIC TANK 1,500 GAL. P&L MONOLITHIC TANK <br /> NO CROSS OVER <br /> 9'-4" 7" '� TO BE USED <br /> BETWEEN TANKS <br /> 10'-6"- <br /> SEPTIC SYSTEM; PROFILE SEPTIC SYSTEM; SIDE VIEW <br /> 1 rr <br /> C <br /> 1/2"= -0 <br /> IV <br /> 0 <br /> V M <br /> TRENCH FOR POWER CONTROL <br /> LCABLES TO BUILDING 0 Q <br /> 1500 GAL. RECIRCULATING GRAVITY FLOW OUT <br /> SEPTIC TANK TO LEACH FIELD _ _ ....__ .......__. __.._ o o Fes_ <br /> _. .....__.. <br /> � o <br /> ' r151101.,00 GAL. I"lnl_ MONOLITHIC � <br /> MM3U RECIRCULATION VALVE GAL. P&L MONOLITHIC <br /> POWER& CABLES TO <br /> SEPTIC TANK SEPTIC TANK 6 >w..� � d. V X a Z <br /> CONTROL PANEL <br /> a <br /> ° 0 � LnZ <br /> co <br /> 3'-0" <br /> I: 111A1t Go <br /> PUMPING ASSEMBLY <br /> DUPLEX U -,; <br /> INLET <br /> 4" COUPLINGS <br /> V <br /> 114" PER FOOT SLOPE <br /> FROM BUILDING. (APPROX <br /> 113 FEET AWAY) <br /> FLOW SPLITTER VIII BASIN <br /> F n_ r rl <br /> 21 <br /> d <br /> 00 <br /> 3 4" PERFORATED SDR 35 <br /> _ 000000 z <br /> DISTRIBUTION LINES SOIL COVER O <br /> ` NATIVE SOIL BACKFILL 6" MIN, 24" MAX <br /> FLOW SPLITTER WI BASIN <br /> E - SEE DETAIL F o ~Q, <br /> CLEAN WASHED GRAVEL 2" MIN. � <br /> o (314" TO 2', 0% PASSING#200 U <br /> T - VENT FAN ASSEMBLYAPPROVED STRAW PAPER 12 MIN- w <br /> m (90 W) SEE SHEET G OR FILTER FABRIC 6„ C] <br /> E FOR DETAILS <br /> Datum 0.0 t. <br /> C) —� <br /> oLl:x I J. t ..._. <br /> rn „ <br /> m gl j NATIVE 501L I I I <br /> I II1...1Ii -�IL �[- �I I <br /> Lo <br /> 03" FILTRATE RETURN LINE <br /> SOIL RDTOTlLLED &SCARIFIED, -- 36'-0" <br /> Lu <br /> SUBGRADE SOIL BROKEN UP BY °4 <br /> ROTOTILLER <br /> SLOPE 114" PER FOOT TOWARDS GARDEN COMPOST OR PEAT <br /> RECIRCULATION TANK <br /> / - 1_1 - '-I - ' 1 _ 1 I - _ - - <br /> N °_' '_° _' 24"TO 48" 1- _ FILTER BED PROFILE: G-G' <br /> 1--, 1 1 1 1 1�1 C�+p <br /> (TYP.) ��6Vl7fa,� <br /> Q 1�1 I 1 r-1 1 1 1-, 1 , ,^I _ 1_l - I_I , 1 , , 1 �, �• <br /> N.T.S <br /> 04" SDR35 SOLID <br /> ADVANTEX AX20 POD (TYP.) SEE --■- °-° _ _ _ _ _ - <br /> PIPE WI CAP <br /> pSHEET G3 FOR DETAILS - 1 I - 1-1 - - 1-+ - - I-1 _ _ _ _ _ m <br /> _ ,-, r_ _I '_' 1_1 r_' 6"ABOVE SOIL <br /> i <br /> JOB NUMBER <br /> E05001 A <br /> - O <br /> x 6„ <br /> 0 <br /> AS NOTED <br /> Q <br /> DATE: <br /> 5/9/2005 <br /> AIR INLET SEE SHEET G3 —04" SCH40 PVC <br /> � FOR DETAILS DRAWN BY: KAMENICKY <br /> oN 04 SDR35 PERFORATED <br /> /� DRAIN PIPE <br /> z E <br /> z 0 U U <br /> DESIGNED BY: <br /> SEPTIC SYSTEM; PLAN VIEW PERFORMANCE WELL D. WELCH <br /> r <br /> 0 ? E H PLAN NOT VALID WITHOUT ORIGINAL ENGINEERING STAMP AND SIGNATURE. SHEET <br /> 7 1/211= '�r-Q11 N.T-S zI PLAN ONLY TO 8E USED FOR THE RESIDENCE AND LOT SPECIFIED IN TITLE BLOCK. <br /> COPYRIGHTO NEIL O.ANDERSON AND ASSOC.,INC. G2 <br /> Z <br /> w <br /> vi <br />
The URL can be used to link to this page
Your browser does not support the video tag.