Laserfiche WebLink
Mr. Ryan Mock <br /> J.R. Simplot Company <br /> April 17, 2020 <br /> Page 4 <br /> [for more information on soil type, see the response to Item D.11.f below]and less than 50 percent <br /> vegetative cover). The area-weighted CN for the non-process area is 93.9. <br /> 4. A detailed description of the facilities that generate wastewater, and all wastewater conveyance, <br /> treatment, and disposal systems. Use site plans and conceptual drawings as appropriate to <br /> illustrate locations and typical construction. Include all treatment processes.The following maps, <br /> plans, and illustrations are needed: <br /> The stormwater pond system reportedly receives about 89,000 gpd of cooling tower and boiler <br /> blowdown, discharge from the reverse osmosis system, and effluent from a package sewage <br /> treatment plant.A diagram of wastewater piping is shown on Figure 2. Flow meters are not <br /> installed on the component piping from each wastewater source.As such, the volume of flow from <br /> each source has not been measured. However, Simplot has estimated the volume of flow from the <br /> packaged sewer plant averages ab <br /> a. A facility location map showing local topography, the facility location and/or boundaries, <br /> streets, and surface waters (including storm water drainage ditches, irrigation canals, and <br /> irrigation/tailwater ditches). <br /> These facility features are shown on Figures 1 and 2. <br /> b. A process flow schematic for the entire treatment and disposal system. Include existing and <br /> proposed flow monitoring devices and sampling locations proposed to determine <br /> compliance with the WDRs. <br /> An overview of the process flow is shown on Figure 2. Detailed process flow schematics for the <br /> disposal system are not available. No treatment for wastewater is proposed. No flow <br /> monitoring devices are installed or proposed. It is proposed that samples be collected from the <br /> stormwater pond discharge and forebay(Figure 2). <br /> c. A scaled treatment plant site plan. <br /> No treatment is proposed. <br /> d. A scaled map showing the limits of all proposed wastewater treatment, storage and disposal <br /> areas. <br /> Figure 2 includes a scaled map of the storage and disposal areas(forebay and stormwater <br /> pond) based on a 2019 survey of the area. <br /> S. Characterization of the source water(the community or process water supply), influent wastewater <br /> quality(prior to treatment or discharge), and treated effluent quality. See Table 1 for a minimum <br /> list of constituents to be analyzed. <br /> Samples of the facility supply well have not been analyzed for all constituents included in Table 1. <br /> Analyses that have been conducted are shown in Tables 4 and 4b in Appendix C. <br /> 6. For POTWs and domestic wastewater facilities; a description of the sewer system, sewer materials <br /> and age, and lift station details (type, location, capacity, backup systems, and alarm features). <br /> Discuss potential inflow and infiltration (1/1) rates in light of local groundwater conditions and <br /> sewer system materials/design. <br />