System Design Description Page 4 <br /> as possible. In normal operation this keeps sludge build up to a minimum by helping to <br /> break up and dissolve the solids, making the nutrients available for the microorganisms. <br /> The clarified water leaves the treatment system through an effluent filter and passes into <br /> the final Effluent Storage compartment. The effluent is now ready for sub-surface <br /> discharge. <br /> The EnviroServer System is controlled by a custom computer control system. The <br /> computer is capable of detecting failures of electrical and mechanical components critical <br /> to the treatment processes and delivering signals both remotely via a modem connection <br /> and locally with a visual and audible alarm. <br /> Detailed specifications are included in the MicroSeptec Installation, Operation, <br /> Maintenance, Trouble shooting and Repair Manual which is attached. <br /> Totalizing Flow Meters <br /> A totalizing flowmeter will be installed on the discharge of the MicroSeptec unit. The <br /> unit is a Sensus Model DN50W which is a displacement type magnetic drive with a <br /> register and a remote meter display unit mounted next to the EnvrioServer control panel. <br /> See the attached catalogue sheets. <br /> Filter Bed <br /> The filter bed area of 3000 sq. feet(50' x 60')will be used to accept the effluent from the <br /> *. MicroSeptec unit. The filter bed will be approximately 30 inches deep. Washed drain <br /> rock(I to 2 inches diameter)will be placed in the bottom of the filter bed to 1 foot above <br /> the bottom. One and a half inch PVC piping will be placed in the filter bed, the space <br /> �,. between piping will be 7 feet. Piping will be connected in a loop configuration. <br /> Cleanouts will be provided for each line. The piping will have forty%inch holes drilled <br /> in the top of the piping approximately 6 feet apart. Each orifice will be covered with an <br /> orifice shield, Orenco#OS 150. A test conducted with water prior to placing the orifice <br /> shields will demonstrate an effluent velocity head of 3 — 5 feet. An inspection box will <br /> be provided to measure the liquid level and sample the soil in the fitter bed. The piping <br /> i. will be covered by a minimum of 4 inches of rock,which will make the total thickness of <br /> rock in the filter bed of 18 inches. The rock will be covered by filter fabric, which will <br /> permit moisture to escape from the filter bed and prevent infiltration of soil from the <br /> �. surface and prevent penetration of roots from shallow rooted plants. The soil will be 6 to <br /> 12 inches thick over the filter bed. Fencing or barriers will be provided to prevent <br /> vehicular traffic on the filter bed area. A copy of the specification for the filter fabric is <br /> attached. <br />