Laserfiche WebLink
Table 1 Summary of Field Measurement Collected During Soil Vapor Extraction Pilot Tests at <br /> Fortner E-Z Serve Station ##100878, 1012 W. Yosemite Avenue, Manteca, California <br /> Test Well MW-5 Monitoring Wells <br /> - _ Vacuum Flow VOC Conc Vacuum, inches of water <br /> Time inches of water din, ppmz in air Well MW-2 Well MW-3 Well MW-4 Well MW-5 <br /> 0 14 _ 20 0 0 005 0 0 <br /> — -- 20 14 20 0 0 0 0 0 <br /> - - _ Blower inoperative for 30 minutes <br /> - -- 60 14 20 0 0 0 0 0 <br /> - 75 34 40 0 0 0 0 0 <br /> _ Blower inoperative for 30 minutes <br /> -- - - - 120 34 40 0 0 01 0 0 <br /> - 135 100 60 26 0 0 0 0 <br /> - = 150 60 50 73 0 0 0 0 <br /> - _ -165 60 50 10 0 0 0 0 <br /> - Blower inoperative for 30 minutes <br /> -_ 195 52 50 95 0 0 0 0 <br /> - - - 210 52 50 12 0 0 0 0 <br /> 225 52 50 14 0 0 0 0 <br /> - Test Well MW-2 Monitoring Wells <br /> Vacuum Flow VOC Conc Vacuum, inches of water <br /> - --- Time inches of water cfm' mZ m air Well MW-8 Well MW-7 Well MW-1 Well MW-6 <br />- -- 0 108 20 32 005 0 0 0 <br /> 15 102 20 17 0 0 0 0 <br /> 30 _ 98 - 20 12 0 0 0 0 <br /> 45 98 20 1 1 1 0 1 0 1 0 0 <br /> '— _ <br /> e NenerveU0G8781sve-rpkxls <br />