My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006642
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1012
>
3500 - Local Oversight Program
>
PR0545948
>
ARCHIVED REPORTS_XR0006642
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/29/2020 10:21:33 PM
Creation date
8/5/2020 4:10:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006642
RECORD_ID
PR0545948
PE
3528
FACILITY_ID
FA0005159
FACILITY_NAME
FILL-EM FAST
STREET_NUMBER
1012
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
21903024
CURRENT_STATUS
02
SITE_LOCATION
1012 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EZ-SERVE MANAGEMENT COMPANY <br /> QUARTERLY GROUNDWATER MONITORING PROGRAM <br /> SAMPLING AND ANALYSIS PLAN <br /> The following sections describe the procedures and protocols followed during this <br /> quarterly groundwater monitoring event at the subject site. <br /> Depth-to-Water Measurements <br /> Prior to sampling the groundwater monitoring wells, the wells were opened to the <br /> atmosphere for approximately one-quarter of one hour, to allow the static water level to adjust <br /> to the open barometric pressure. The depth-to-groundwater was then be measured, using an <br /> oil-water interface probe. The interface probe was lowered slowly until free product or water <br /> was encountered. At this point, the mark on the interface probe wire was read to the nearest <br /> 0.01 feet at the permanent reference point on the top of the well casing If free product was <br /> encountered the probe was lowered until water was encountered. The difference between the <br /> two depths corresponds to the thickness of the free product. The total depth of the well was <br /> then measured using the same probe. A second check for free-product on top of the water <br /> column was made using a disposable bailer The disposable bailer was lowered into the water <br /> to approximately one-half the bailer length The bailer was then removed from the well and <br /> a check for the presence of free petroleum product or a product sheen was made. <br /> In the event that a dedicated bailer or purge tubing existed in the well, the dedicated equipment <br /> was removed prior to sampling, and temporarily stored in a clean, plastic garbage bag <br /> The depth-to-water and bottom of well measurements, and the presence or absence of free <br /> product, was recorded on the field sampling form. In addition, comments regarding the <br /> condition of the well and/or containment box were also be noted on the field sampling sheet <br /> at this time Wells observed to contain a product sheen or free product on top of the water <br /> column were not be purged or sampled <br /> Groundwater Monitoring Well Purging <br /> The depth-to-water and bottom of well measurements were used to calculate the volume <br /> of water contained in one well volume. The following values were used to calculate the <br /> volume of water contained in the well casing and filter pack surrounding the well. <br /> Well_Diameter Gallons/linear foot <br /> 2-inch 0.16 <br /> 4-inch 0.65 <br /> 8-inch filter pack 0.78 <br /> 10-inch filter pack 1.21 <br /> F , <br /> ,The minimum purge volume was calculated to be three times the total well volume.i Once the <br /> mimmurn purge volume has been calculated purging was started. 'Purging was conducted using <br /> k <br />