Laserfiche WebLink
Chevron Groundwater Monitoring Report(192001) Page 2 of 2 <br /> Facility 49-1848—1257 1 osemote Avenue,Manteca,CA Date April 12,2001 <br /> DISCUSSION• <br /> This groundwater monitoring and sampling event was performed by Gettler-Ryan Inc on February 21, 2001 Three <br /> wells were sampled during this event Laboratory test results reported TPHg and benzene as non-detectable in all <br /> wells MtBE concentrations were reported in C-2 at 37 ppb Groundwater elevations across the site increased an <br /> average of approximately 0 94 feet this quarter Groundwater flow was northwest at 0 001 ft/ft <br /> LIMITATIONS: <br /> The findings presented in this letter are based on data and interpretations provided by Gettler-Ryan, Inc Gettler- <br /> Ryan's report is attached The data presented in this summary is accurate only to the degree implied by the sources <br /> and methods used No warranty,expressed or implied, is made by SECOR <br /> If you have any questions,please feel free to call us at(916) 861-0400 <br /> Sincerely, <br /> SECOR International Inc <br /> • <br /> �R;or ffm e <br /> Project Manager <br /> ATTACHMENTS: <br /> • Table I —Screen Intervals <br /> • Attachment A—March 15, 2001 Groundwater Monitoring& Sampling Report by Gettler-Ryan Inc <br /> cc Bob Cochran, Chevron Products Company, P O Box 6004, San Ramon, CA 94583-0804 <br /> Marty Hartzell, RWQCB-CVR,3443 Routier Road, Suite A, Sacramento,CA 95827 <br /> Donna Feletto, Pan Pacific Retail Properties, 8785 Center Parkway, Suite B-350,Sacramento, CA 95823 <br />