0U0 MONITORING WELL PURGING G G P ROTOCOL <br /> EMCON MEASURE AND RECORD DEPTH TO WATER <br /> ASSOCIATES AND WELL TOTAL DEPTH <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS. USING THE FOLLOWING EQUATION. <br /> DO NOT SAMPLE WELL FOR P. Tt r 2 h x 7 48 x 3 <br /> DISSOLVED CONSTITUENTS. where; <br /> P calculated purge volume(ga#Ions) <br /> n s 3.14 <br /> r radius of well casing in feet <br /> h = height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMIT THE CALCULATED PURGE VOLUME WHILE <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUND-WATER STABILIZATION <br /> CALCULATED PURGE VOLUME INDICATOR PARAMETERS(pH, CONDUCTIVITY. <br /> TEMPERATURE)AND TURBIDITY AT INTERVALS <br /> OF ONE CASING VOLUME <br /> NO YES <br /> FINAL TWO SETS OF GROUND-WATER <br /> STABILIZATION INDICATOR PARAMETER WELL RECHARGES TO A LEVEL <br /> MEASUREMENTS MEET THE FOLLOWING SUFFICIENT FOR SAMPLE <br /> CRITERIA COLLECTION WITHIN 24 HOURS <br /> pH = t 0 1 pH units OF EVACUATION TO DRYNESS. <br /> COND = t 10% <br /> TEMP = 1 0 OF <br /> YES NO <br /> EYES NO <br /> FIELD TEST FIRST RECORD WELL <br /> WELL PURGING CONTINUE PURGING, RECHARGE WATER FOR AS DRY FOR <br /> CRITERIA MET, EVACUATE ADDITIONAL INDICATOR PARAMETERS PURPOSES OF <br /> PROCEED TO CASING VOLUME OF AND TURBIDITY,THEN SAMPLING. <br /> WELL SAMPLING WATER, MONITORING PROCEED TO WELL <br /> INDICATOR PARAMETERS SAMPLING. <br /> FOR STABILITY, <br /> FIGUREEMCON <br /> MONITORING WELL PURGING PROTOCOL A-'1 <br /> Associates <br />