Laserfiche WebLink
June 23, 2021 Lab ID : STK2137082 <br /> San Joaquin Co.Environmental Health Dep Customer : 3-17919 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrate+Nitrite as N 450ONO3F (SP 2106711-001) MSD mg/L 5.609 96.0% 5-285 <br /> MSRPD m 5.609 0.1% :530.4 <br /> 450ONO3F 05/20/21:207567VVH CCB mg/L 0.088 0.2 <br /> CCV mg/L 11.22 97.0% 90-110 <br /> CCB mg/L 0.162 0.2 <br /> CCV mg/L 11.22 96.7% 90-110 <br /> Nitrate as NO3 450ONO3F 05/20/21:205642VVH Blank m L ND <0.9 <br /> Nitrate Nitrogen 450ONO3F 05/20/21:205642VVH Blank mg/L ND <0.2 <br /> Nitrite as Nitrogen 450ONO3F 05/20/21:205643VVH Blank mg/L ND <0.2 <br /> LCS mg/L 1.218 100% 80-120 <br /> MS mg/L 0.6090 98.0% 50-150 <br /> (SP 2106711-001) MSD mg/L 0.6090 98.9% 50-150 <br /> MSRPD m 0.6090 0.0050 50.2 <br /> 450ONO3F 05/20/21:207564VVH CCB mg/L 0.00800 0.012 <br /> CCV mg/L 1.218 101% 90-110 <br /> CCB mg/L 0.00800 0.012 <br /> CCV mg/L 1.218 101% 90-110 <br /> MBAS 55400 05/20/21:208000jba CCB mg/L -0.0351 0.25 <br /> CCV mg/L 1.000 96.1% 90-110 <br /> CCB mg/L -0.0351 0.25 <br /> CCV m 1.000 1 96.1% 90-110 <br /> MBAS Extraction 5540C 05/20/21:20594Ijba Blank mg/L ND <0.1 <br /> LCS mg/L 0.5000 94.9% 86-114 <br /> BS mg/L 0.5000 92.1% 86-114 <br /> BSD mg/L 0.5000 94.2% 86-114 <br /> BSRPD m L 0.5000 0.010 1 <0.1 <br /> Definition <br /> ICB :Initial Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> BS :Blank Spikes-A blank is spiked with a known amount of analyte.It is prepared to verify that the preparation process is not <br /> affecting analyte recovery. <br /> BSD :Blank Spike Duplicate of BS/BSD pair-A blank duplicate is spiked with a known amount of analyte.It is prepared to verify that <br /> the preparation process is not affecting analyte recovery. <br /> Dup :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate.The relative percent difference is an <br /> indication of precision for the preparation and analysis. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> BSRPD :BS/BSD Relative Percent Difference(RPD)-The BS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> <1/4 :High Sample Background-Spike concentration was less than one forth of the sample concentration. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Explanation <br /> -435 :Sample matrix may be affecting this analyte.Data was accepted based on the LCS or CCV recovery. <br /> Page 8 of 8 <br />