My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
1600 - Food Program
>
PR0546092
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2020 5:01:47 PM
Creation date
8/11/2020 2:58:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546092
PE
1617
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AM/PM-ASP PETROLEUM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES P`11� 'A <br /> 01 A. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. <br /> A3.4 B. ALL DENOTED DIMENSIONS ARE TO BE USED. PLANS SHALL NOT BE SCALED. <br /> 7 C. EXTERIOR WALL ARE 2x6, INTERIOR WALLS 2x4 U.N.O., SEE STRUCTURAL PLANS FOR FRAMING <br /> REQUIREMENTS. <br /> DESIGN <br /> 61 -82" VANILLA SHELL C-STORE D. SEE PLUMBING PLANS FOR DIMENSIONS TO PLUMBING FIXTURES <br /> E. REFER TO SHEET Q1.1 FOR FOR EQUIPMENT PLAN. <br /> F. REFER TO SHEET Q2.1 FOR EQUIPMENT SCHEDULE. Architectural <br /> 27'-1" 8'-0" 7'-11 G. ALL EQUIPMENT SHALL MEET ACCESSIBILITY REACH RANGE REQUIREMENTS. <br /> H. PROVIDE PLASTIC CORNER GUARDS AT EDGES BELOW 6'-0". Solutions Group <br /> I. ALL COUNTERTOPS SHALL BE MAX. 34" A.F.F. WITH A 3-FOOT WIDE TRANSACTION AREA AT <br /> 1A z CASHIER. CONTRACTOR SHALL COORDINATE WORK WITH CABINET INSTALLER FOR CABINET 2455 Bennett Valley Rd.Suite A-102 <br /> :3 INSTALLATION. CONTRACTOR TO ROUTE UTILITIES THROUGH CABINETS. CONTACT CABINET INSTALLER Santa Rosa, CA. 95404 <br /> Nv = FOR SITE SPECIFIC CABINET SHOP DRAWINGS. <br /> U <br /> ~ J. 4" HIGH BACKSPLASH AT ALL COUNTERTOPS THAT TERMINATE AT WALL. BACKSPLASH TO MATCH <br /> 1A 15 1A 15 MAIN SWITCHGEAR COUNTERTOP MATERIAL. <br /> N <br /> K. THE CONTRACTOR SHALL ASSIST STORE PERSONNEL BY ASSEMBLING MERCHANDISE GONDOLAS <br /> C o o AND SHELVING AS SHOWN ON Q1.1. <br /> ARch/T� <br /> L. ALL EQUIPMENT AND CABINETS SHALL BE FREE OF SHARP EDGES. CONTACT MANUFACTURER OR <br /> PREP EDGES FOR SAFETY. �G y W . PFS <br /> z 17 C� M. CONTRACTOR SHALL ROUTE ALL CONDENSATE DRAIN LINES TO FLOOR SINKS. Q,C <br /> N. CONTRACTOR SHALL INSTALL NEW PARTITIONS/WALLS WITH GYPSUM WALL BOARD AND FINISHES <br /> 504 <br /> U AS NOTED ON FINISH SCHEDULE AND INTERIOR ELEVATIONS ON SHEET A2.3 THRU A2.6. ALL REN. 1/31/119 <br /> c� 2 PARTITIONS/WALLS SHALL BE BRACED FOR LATERAL FORCES, PER BUILDING CODE REQUIREMENTS. <br /> z 0. FLAME SPREAD CLASSIFICATIONS FOR INTERIOR WALLS SHALL COMPLY WITH LOCAL CODES. <br /> LIJ <br /> CD 1 C =) 1 A2.6 3 2 P. FIRE EXTINGUISHERS (2A:10B:C) SHALL BE INSTALLED AT SALES COUNTER, BACK ROOM, OFFICE, <br /> J & FUEL CANOPY LOCATIONS IF NOT SHOWN ELSEWHERE ON THESE DRAWINGS. VERIFY WITH �TFOFCA0 <br /> F0 <br /> � <br /> 3 _< OWNER FOR DETAILS, CONFIRM FINAL DETAILS WITH LOCAL FIRE INSPECTOR. Seal <br /> Of Q. CONTRACTOR SHALL ASSIST THE OWNER WITH STORE EQUIPMENT TO PREPARE A DELIVERY <br /> A3.4 w STAGING AREA. COORDINATE WITH OWNER FOR THE DELIVERY SCHEDULE AND SHIPPING DAMAGES, <br /> w <br /> AS APPLICABLE. <br /> 2 F. R. CONTRACTOR SHALL PROVIDE A CLEAN, SMOOTH SURFACE FOR GRAPHICS INSTALLATION. bp <br /> 01 S. ALL DIMENSIONS SHALL BE FIELD VERIFIED BY CONTRACTOR FROM CABINET AND EQUIPMENT <br /> A3.3 _ _ __ CLEARANCES PRIOR TO WALL ERECTION. DISCREPANCIES SHALL BE DIRECTED TO OWNER. <br /> SIM T. WATER HEATERS SHALL BE CAPABLE OF DELIVERING MIN. 120° WATER TO ALL SINKS. <br /> U. ALL FLOOR/WALL TILE AND COVE BASE SHALL BE INSTALLED BY THE GENERAL CONTRACTOR <br /> 8 ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS. <br /> V. ALL DOORS MUST HAVE NO MORE THAN 5 LBS OPENING FORCE AND MUST HAVE A SWEEP <br /> 1A 1C <br /> 7 A2. 5 �� PERIOD OF 3 SECONDS TO CLOSE FROM 70° <br /> QSR _ OPEN TO 3'$ FROM THE LATCH. <br /> —1C14 W. CARBONATOR BACK-FLOW PREVENTOR DRAIN LINE OUTLET SHALL BE TO NEW FLOOR SINK <br /> (VANILLA 6 FD 2 PROVIDED FOR THIS AREA. <br /> SHELL) KEYED NOTES <br /> UJ <br /> CD2 Z ALUMINUM ENTRANCE AND STOREFRONT SYSTEM, REFER TO SHEET A5.1 <br /> i O 1 B 6'-0" �i N O & SPECIFICATION. <br /> LLJN N J 6 r`' 2 <br /> -i i 2O INSTALL 6"0 PVC CHASE FOR FOUNTAIN SYRUP LINES. <br /> NO 0F_ 3O FLOOR RECEPTACLES, REFER TO ELECTRICAL PLANS. <br /> 4 <br /> 20 SLAB 1 C 18 O O ROOF LADDER PER DETAIL 7/A4.1 <br /> r7 J <br /> 9 21 7 <br /> O 1" MINIMUM AIR GAP AT PREFABRICATED COOLER/FREEZER <br /> C O 6 A2.6 8 „ O DEPRESSED SLAB, REFER TO SLAB PLAN. m <br /> 2,-7 <br /> 5 O LINE OF CANOPY ABOVE U� <br /> Nil z <br /> ....... (D DOUBLE SWING METAL GATE PROVIDED BY SHOPCO O w <br /> >LU <br /> o <br /> EXITO THRESHOLD, REFER TO DOOR SCHEDULE ON SHEET A5.1 CD <br /> z <br /> o = <br /> LO <br /> C ORIDOR 3— — 3— 10 LINE OF SOFFIT ABOVE <br /> NCD <br /> `" 1 C 11 LINE OF CLERESTORY CEILING OPENING, REFER TO WINDOW SCHEDULE M <br /> ON SHEET A5.1 Q <br /> 1 <br /> 113 —c!3'- I WOMEN ZA 12 WALL SIGNS z <br /> T Lo <br /> 1 A I FD 13 TRANSITION STRIP w <br /> CN <br /> UJ i 6 9 6 14 STEEL COLUMNS UNDER WINDOW SILL FOR STOREFRONT PROTECTION, o <br /> � 02 0 1 C REFER TO STRUCTURAL PLANS FOR SIZE AND LOCATION. ro <br /> o <br /> A3.3 12 A2. 10 16 ,� <br /> 0) I 15 ROOF DRAIN AND OVERFLOW, REFER TO CIVIL PLANS FOR CONTINUATION <12 a a a a a a a <br /> � SIM. 9 <br /> 1 1 11 O 16 CANOPY DOWNSPOUT, REFER TO CIVIL PLANS FOR CONTINUATION <br /> 00 1 9 <br /> 0 <br /> N <br /> � <br /> N — — — — — — — — 17 FUTURE SOLAR EQUIPMENT <br /> — — — <br /> 1A O 1A — — — — — — — — — — 1A O 18 CO2 SAFETY MONITORING EQUIPMENT, REFER TO SHEETS Q1.1 AND Q2.1 <br /> 1 A <br /> 14 14 O FOR LOCATION AND SPECIFICATION <br /> 1 0 1 19 17 ENLARGED 19 RECESSED STAINLESS STEEL FILL BOX WITH QUICK–DISCONNECT MALE <br /> QI A2.6 RESTROOM FILL AND VENT HOSE CONNECTION FOR CO2 TANK <br /> N PLAN Q <br /> 020 VANILLA SHELL – INSTALL GYP. BD. AT INTERIOR SIDE OF FINISHED Q W <br /> 0 <br /> ca <br /> SHELL. 0 <br /> NI21 VANILLA SHELL - NO SLAB IN THIS AREA FOR FUTURE TENANT UTILITY Q W <br /> C14 /02 7 02 7 6'-94„ WORK. Wco <br /> Cn z A3.2 02 E D Q Q Q � <br /> 52" 3,_8$„ 13'-7" 4,_1$„ 2 _0 A3.4 12'-0" A3.1 2 -0„ 4,_1$„ A3.2 13'-7" A3.1 1g 2'-10" 3,_0, 2" 52" 13'-62.' LEGEND 0 •• <br /> o <br /> U=911 <br /> WOOD FRAMED WALL z W = 0 Q <br /> z Q � / , <br /> 0 01 PREFABRICATED COOLER/FREEZER WALL # J O U <br /> L) A2.1 v M <br /> D 2x6 STUDS @ 16"o.c. W/ SOUND BATT INSULATION W W U <br /> o VANILLA SHELL �� C-STORE ` <br /> Q W W W <br /> 1A 2x6 STUDS ® 16"o.c. W/ THERMAL INSULATION <br /> () Cn z <br /> 0 U <br /> 1 B 2X6 STUDS ® 16" o.c. : 1-HR RATED ASSEMBLY <br /> 0 <br /> Ir L a <br /> D <br /> F- 1 C 2X6 STUDS @ 16" o.c. 2-HR RATED ASSEMBLY Q 0 Q <br /> Ld <br /> Uz <br /> �2 2x4 STUDS @ 16"o.c. Q <br /> 01 CONSTRUCTION FLOOR PLAN W <br /> of <br /> - SCALE: 1/4"-1'-0" 2A 2x4 STUDS @ 16"o.c. W/ SOUND BATT INSULATION (n <br /> OX DOOR SYMBOL, REFER TO SHEET A5.1 FOR DETAILS <br /> z <br /> 0 O WINDOW SYMBOL, REFER TO SHEET A5.1 FOR DETAILS <br /> D <br /> U <br /> N <br /> VANILLA SHELL <br /> z <br /> Project Number <br /> 0 <br /> OCCUPANCY LOAD SPA16002.0 <br /> Q <br /> U <br /> z QSR 2,360 S.F. (2,360/200) = 12 Sheet Name <br /> Q <br /> �I TOTAL (NET): 2,349 S.F. = 12 OCCUPANTS <br /> o TOTAL (GROSS): 2,360 S.F. CONSTRUCTION <br /> 0 <br /> (0 <br /> EXITS REQUIRED: 2 FLOOR PLAN <br /> 0- EXITS PROVIDED: 2 <br /> V) <br /> w <br /> VANILLA SHELL <br /> J <br /> O <br /> w <br /> d <br /> H <br /> Sheet Number <br /> z <br /> w <br /> 0 <br /> z <br /> w <br /> 0- <br /> Al <br /> l b <br /> o ■ <br /> z <br />
The URL can be used to link to this page
Your browser does not support the video tag.