My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
1600 - Food Program
>
PR0546092
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2020 5:01:47 PM
Creation date
8/11/2020 2:58:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546092
PE
1617
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AM/PM-ASP PETROLEUM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CODES AND STANDARDS COOLER/FREEZER ALARMS <br /> NSF STANDARDS: COMPLY WITH APPLICABLE NATIONAL SANITATION COOLER/FREEZER ALARMS AS MANUFACTURED BY: <br /> FOUNDATION (NSF) STANDARDS AND RECOMMENDED CRITERIA. PROVIDE iA <br /> EACH PRINCIPAL ITEM OF FOOD SERVICE EQUIPMENT WITH A NSF NATIONAL CONTROLS CORPORATION DESIGN <br /> "SEAL OF APPROVAL" <br /> CU-1 1725 WESTERN DRIVE <br /> AND CU-3 UL LABEL: WHERE AVAILABLE, PROVIDE UL LABELS ON PRIME WEST CHICAGO, IL. 60185 <br /> ELECTRICAL COMPONENTS OF FOOD SERVICE EQUIPMENT. PROVIDE (800) 323-2593 A r c h i t e c t u r a l <br /> CU-2 OTHERUL "RECOGNIZED MARKING" ON <br /> I COMPONEN S SGNIFYING LISTINGBY ULTITELECTRICAL <br /> WHERE <br /> Solutions Group <br /> I � PROVIDE THE FOLLOWING: <br /> ROOF I ROOF HEALTH CODE: INSTALL FOOD SERVICE EQUIPMENT IN ACCORDANCE (1) DUAL KIT #TNC-TM100-KT2A 2455 Bennett Valley Rd.Suite A-102 WITH LOCAL HEALTH DEPARTMENT APPLICABLE REGULATIONS. KIT INCLUDES: <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Santa Rosa, CA. 95404 <br /> • 2 THERMOMETER UNITS <br /> 1. SHOP DRAWINGS UPON APPROVAL OF BID, SUBMIT 3 SETS OF • 2 TEMPERATURE PROBES WITH 6'-0" WIRE <br /> COMPLETE DETAILS, MECHANICAL AND ELECTRICAL REQUIREMENTS, • 1 TRANSFORMER <br /> S L L S AND INSTALLATION INSTRUCTIONS OF EACH ITEM. INCLUDE INFORMATION • 1 STAINLESS STEEL TWIN ENCLOSURE <br /> ON ROUGHING IN DIMENSIONS, SERVICE CONNECTION REQUIREMENTS, <br /> TRAP AT RISER (TYP.) OPENINGS, DISPLAY AND LATCH DOOR MANUFACTURER'S INFORMATION, ADDITIONAL PROBE WIRE #X02-22GNO-820 <br /> - S - - S - - S - COMPLETE FLOOR PLANS AND EQUIPMENT SPECIFICATIONS. A R cyiT <br /> INSTALLATION: � <br /> 2. TAKE FIELD MEASUREMENTS TO ASSURE ACCURATE FIT OF FABRICATED \G� y W . PFQ FO,� <br /> - - L - - - - L - - - - L - - I EQUIPMENT. • INSTALL THERMOMETER UNITS IN CASHIER AREA. Q, <br /> 3. INCLUDE WARRANTY INFORMATION ON ALL EQUIPMENT. • INSTALL TEMPERATURE PROBE IN EACH RESPECTIVE COOLER/FREEZER - 504 <br /> L COMPARTMENT. SPLICE THE 6'-0" PROBE WIRE WITH ADDITIONAL REN. 1/31/19 <br /> PROBE WIRE AS REQUIRED TO RETURN TO CASHIER AREA. <br /> LEGEND L • COMPLETELY SEAL ANY AND ALL INTRUSIONS TO COOLER/FREEZER LP �Q <br /> S - COMPARTMENTS. �TFOF CA\-�FC�� <br /> ---S--- SUCTION • LABEL ALL THERMOMETER UNITS PER RESPECTIVE COOLER/FREEZER Seal <br /> ---- L---- LIQUID TRAP AT RISER (TYP.) COMPARTMENTS. <br /> ----C---- CONDENSATE DRAIN • SET ALARM TEMPERATURE AS FOLLOWS: <br /> I L •WALK-IN COOLER: +35° F. bp <br /> _C_ I C- - C- C -C -NOTE: •WALK-IN FREEZER: 0° F. <br /> ALL SUCTION LINES TO BE INSULATED • LOCATE TEMP. PROBES A MIN 2'-0" FROM WALL AND 5-0" FROM DOOR. <br /> TRAP LEAVING REFRIGERATED ROOM TRAP LEAVING REFRIGERATED ROOM WALK-IN COOLER NOTES <br /> 1.0 GENERAL NOTES: 5.0 REFRIGERATION: <br /> 1.1 WALK-IN COOLER SHALL BE PREFABRICATED METAL CLAD PANELS 5.1 ALL EQUIPMENT MUST CONFORM TO CONDENSING UNITS AND UNIT <br /> BY CUSTOM COOLERS INC. OR EQUAL. DESIGNED IN MODULAR COOLERS SCHEDULE AS OUTLINED ON THIS SHEET. EQUIPMENT MUST <br /> CONCEPT TO FACILITATE ACCURATE JOB SITE ASSEMBLY. HAVE UL LISTING FOR THE APPLICATION AS SPECIFIED. <br /> 01 EVAPORATION PIPING SYSTEM 2.0 PANEL CONSTRUCTION: 5.2 CONDENSING UNIT AS SPECIFIED SHALL HAVE THE FOLLOWING: <br /> SCALE: N/A 2.1 ALL PANELS SHALL BE FOAMED-IN-PLACE CLASS 1, POLYURETHANE 1. HIGH EFFICIENCY ALUMINUM FIN. COPPER TUBE CONDENSER. <br /> CONSTRUCTION WITH 3 1/2 COMPOSITE PANEL. THE R VALUE TO 2. COMPRESSOR CONTRACTOR. <br /> BE 30 WITH A DENSITY F 2.2 POUNDS PER CUBIC FOOT. 3. HIGH AND LOW PRESSURE CONTROLS <br /> EVAPORATOR COILS 2.2 THE PERIMETER OF ALL PANELS SHALL BE BUTT JOINT 4. WEATHER RESISTANT HOUSING WITH WEATHER-PROOF ELECTRICAL <br /> CONTROL BOX. <br /> FANS REFG. REFG. CAPACITY POWER BOX DEFROST FAN 2.3 PANELS TO BE JOINED TOGETHER BY ENGAGING A CAM-ACTION 5. ACCESS GUARD. <br /> BOX LOAD HEATCRAFT B.T.U.'S 6. LOW AMBIENT CONTROL VALVE (CVP II) FPR FLOATING HEAD. <br /> TYPE CHG. SUPPLY TEMP. HEATER MOTOR LOCKING DEVICE. THE CAM ACTION DEVICE WILL DRAW THE SECTIONS � <br /> REQUIREMENTS QTY' MODEL # QTY' CFM R LBS. 1 HR. TOGETHER TO FORM A TIGHT SEAL. 7. CRANKCASE HEATER. Q <br /> EACH EACH .F MCA MCA 8. LIQUID LINE FILTER DRIER, SIGHT GLASS AND SERVICE VALVE. <br /> CU-1 448A 2.4 STANDARD PANEL FINISH SHALL BE 26 GAUGE STUCCO EMBOSSED 9. ELECTRIC DEFROST TIMER. <br /> 32'-9" O.D. COOLER CU-2 COOLER 42,737 BTU/H 4 LCA6110AB 2 1,300 449A -- 11,000 115/1/60 +35 -- 1.8 GALVANIZED STEEL SKIN EXTERIOR WITH WHITE INTERIOR. 10. EXPANSION VALVES. m <br /> REACH-IN 448A/ 2.5 PROVIDE 7-1 2" DOOR SILL HEIGHTS FOR GLASS DISPLAY DOORS. 11. THERMOSTAT AND SOLENOID. cn <br /> CU-3 FREEZER 6,623 BTU/H 1 LCE676BB 2 1,300 449A -- 7,448 208/230/1/60 -10 -- 1 / <br /> 2.6 INSULATION IS CLASS 1, POLYURETHANE FOAM WITH A FLAME SPREAD 5.3 EVAPORATOR COILS SPECIFIED IN EVAPORATOR COIL SCHEDULE. z ~ <br /> LESS THAN 25 AND A SMOKE DEVELOPMENT OF LESS THAN 450. � � <br /> <„ w <br /> CONDENSING UNITS 5.4 EXPANSION VALVE SHALL BE SIZED BY UNIT COOLER MANUFACTURER w o <br /> 2.7 CERTIFICATIONS: UL AND NSF APPROVED FOR PROPER REFRIGERATION. AS HEAD PRESSURE IS ALLOWED TO 0 c� <br /> N <br /> i BOX LOAD REFG. REFG. B.T.ACIT MIN. MAX. 2.8 MEASUREMENTS AND CONFIGURATIONS REFER TO THIS SHEET. DROP DURING LOW AMBIENT CONDITIONS, EXPANSION VALVE NEEDS z <br /> HEATCRAFT SUCTIONPOWER DEFROST TO BE OVERSIZED TO ALLOW FLOW AT LOWER PRESSURE DIFFERENTIAL o <br /> REQUIREMENTS QTY MODEL TEMP. TYPE CHG. 1 HR. SUPPLY TIMER CCT. FUSE 3.0 COOLER WALK-IN DOOR RATIO. J <br /> _i # R LBS. EACH AMP. SIZE MANUFACTURED BY CUSTOM COOLERS, INC. OR EQUAL. m <br /> CU-124,752 5.5 THERMOSTATS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AND <br /> CU-2 COOLER 42,737 BTU/H 2 MOZ03OM63C +23° 448A/449A -- @95° AMB. 208/230/3/60 AIR -- -- 3.1 36" x 82" CUSTOM *ANTHONY 103NT (HEAVY DUTY) ALL GLASS SHALL BE WHITE RODGERS MODEL #1609-101 OR EQUAL, TAMPER-PROOF Q <br /> °REACH-IN 7,597 PASS-THRU DOOR, SLIMLINE BLACK HANDLE, PRO LEDs, NO WITH PROPER TEMPERATURE RANGE, AS REQUIRED ON THIS DRAWING. <br /> CU-3 FREEZER 61623 BTU/H 1 MOZ0251_63C -22448A/449A -- @95° AMB. 208/230/3/60 AIR -- -- THRESHOLD, CYLINDER DOOR LOCK, ALL BLACK FINISH DOOR & FRAME, OPTIONAL MANUFACTURERS: JOHNSON OR RANCO OR EQUAL. z <br /> STAINLESS STEEL INTERIOR/EXTERIOR 10" KICKPLATES. <br /> 5.6 SOLENOIDS SHALL BE FURNISHED LOOSE FOR EACH SYSTEM AS 0 <br /> N 3.2 LOCATION AND SWING AS SHOWN ON THIS SHEET. RECOMMENDED BY CONDENSING UNIT MANUFACTURER. UJ <br /> w 3.3 FREEZER WALK-IN DOOR 5.7 CONDENSATE PIPING SHALL BE COPPER OR PVC AND TRAPPED AFTER o <br /> SIN MANUFACTURED BY CUSTOM COOLERS, INC. OR EQUAL. WALL PENETRATION. HEAT TAPE AND INSULATE WHERE REQUIRED ') <br /> C)3.4 DOOR SHALL BE NOMINAL 3 1/2" FOAMED-IN-PLACE CLASS 1, TO PREVENT FREEZE UP. <br /> POLYURETHANE CONSTRUCTION. 5.8 REFRIGERATION WARRANTY SHALL BE A MINIMUM OF ONE (1) YEAR PARTS a a a a a a a <br /> 00 3.5 DOOR TO BE HINGED, IN-FIT, AND HAVE 36" HIGH DIAMOND PLATE <br /> FOUR (4) YEAR COMPRESSOR WARRANTY AND NINETY (90) DAYS SERVICE. <br /> 0 KICK PLATES FOR INTERIOR AND EXTERIOR. 5.9 HEAT SENSOR TO BE LOCATED 1'-2" ABOVE DOOR FRAME TO <br /> ALLOW FOR GRAPHICS INSTALLATION. <br /> N 3.6 HINGES SHALL BE CAM-RISE WITH BRIGHT SILVER ANODIZED FINISH <br /> ON FRAME AND DOOR TRIM, TWO HINGES PER DOOR. 6.0 REFRIGERATION INSTALLATION <br /> 3.7 LATCH AND STRIKE TO HAVE A SATIN SURFACE CHROME FINISH WITH 6.1 EVAPORATOR COILS SHALL BE MOUNTED FROM CEILING WITH 5/16" <br /> o w PROVISION FOR PADLOCK. LATCH TO HAVE INSIDE SAFETY RELEASE MINIMUM FASTENERS. <br /> ry o TO PREVENT ENTRAPMENT. <br /> z 3.8 DOOR TO HAVE REPLACEABLE GASKETS FOR A POSITIVE SEAL AND 6.2 CONDENSING UNITS ARE MOUNTED ON THE ROOF AND MUST BE LEVEL <br /> C14 1 WITH ITS BASE ANCHORED TO PREVENT MOVEMENT. ALLOW PROPER Q <br /> 0 LO AN ADJUSTABLE VINYL WIPER GASKET FOR SEAL AT DOOR FRAME CLEARANCE FOR AIR SUPPLY TO AND FROM UNIT AND FOR PROPER <br /> (D I a THRESHOLD. MAINTENANCE ACCESS. Q W <br /> � ro <br /> 3.9 A FLUSH MOUNTED 2" DIAL THERMOMETER OF CORRECT TEMPERATURE O =5V) `� o RANGE SHALL BE PROVIDED AT THE DOOR. THE THERMOMETER SHALL 6.3 SUCTION LINES AT TOP OF RISER ON ROOF SHALL BE SLOPED 1 PER <br /> M o BE EASILY CALIBRATED. THE THERMOMETER SENSING BULB ON THE TEN (10) FEET TO COMPRESSOR. ALL SUCTION LINES SHALL BE SIZED Q Z <br /> 0 N AND TRAPPED. INSULATE TO PREVENT SWEATING. W CM <br /> i <br /> o INTERIOR OF THE DOOR SECTION TO HAVE PROTECTIVE COVER. W <br /> z 3.10 LIGHTING SHALL CONSIST OF THREE VAPOR-PROOF LIGHT FIXTURES 6.4 LIQUID LINES AND SOLENOID VALVE SHOULD BE INSTALLED IN THE Q Q 0 Q In <br /> W TO BE FURNISHED LOSE, AND A LIGHT SWITCH WITH PILOT LIGHT LIQUID LINE JUST AHEAD OF EXPANSION VALVE IN COOLER. <br /> FLUSH MOUNTED ON EXTERIOR. THE WIRING SYSTEM SHALL BE Z W = Q <br /> o a' APPROVED BY UNDERWRITERS LABORATORY. 6.5 BRAZING SHALL BE SILVER BEARING SOLDER HIGH TEMPERATURE OR <br /> 0 �`' EQUIVALENT ALLOY SUITABLE FOR THIS APPLICATION. NO "SOFT Q O <br /> 0 3.11 PROVIDE LOCKS ON DOORS AS INDICATED ON COOLER PLAN. SOL EMS" PERMISSIBLE. <br /> ER I SIIBLBRAZ . NITROGEN IS TO BE PURGED THROUGH THE # J O U <br /> 3.12 PROVIDE WALL BUMPER GUARD MM <br /> 6.6 LEAK TEST THE ENTIRE SYSTEM AFTER ALL REFRIGERATION W W Q <br /> 4.0 GLASS DISPLAY DOORS: CONNECTIONS HAVE BEEN COMPLETED. LEAK TESTING SHALL BE (n (n U <br /> zMANUFACTURED BY ANTHONY OR EQUAL PERFORMED WITH AN ELECTRONIC LEAK DETECTOR. 0 ��//�� W W W <br /> 4.1 30 X 75 H. DISPLAY DOORS (SILL AT 7-1/2 A.F.F.) 6.7 THE SYSTEM MUST BE EVACUATED WITH A VACUUM PUMP, HAVING U VJ 3 Z <br /> 0 THE CAPABILITY OF PULLING A VACUUM OF 50 MICRONS OR LESS. <br /> J _ 4.2 ENERGY SAVER CONTROLS THE PUMP SHOULD BE CONNECTED TO BOTH THE HIGH AND LOW U_ Q <br /> D n1004.3 FINISH TO BE SMOOTH BLACK. SIDES OF THE SYSTEM. O Q <br /> ,r,lop 3 -92 3'-1" 2 -32 4.4 COOLER DISPLAY DOORS SHALL HAVE 2-PANE GAS FILLED NON-HEATED, 6.8 DURING CHARGING AND START-UP MAKE SURE SHIPPING RESTRAINTS / 1 a <br /> INSULATED SAFETY GLASS ARE REMOVED AND ALL ELECTRICAL AND MECHANICAL CONNECTIONS V <br /> v ARE TIGHT. SET HIGH LOW PRESSURE SWITCH AS REQUIRED. (W <br /> 4.5 LED LIGHTING <br /> Q� 6.9 INSTALLATION AND SERVICE OF THIS EQUIPMENT SHOULD BE <br /> 0 14 1 4.6 36 DEEP SHELVES, (7) PER DOOR PERFORMED BY QUALIFIED AND EXPERIENCED REFRIGERATION <br /> 4.7 KEY CYLINDER LOCK AT EACH DOOR. MECHANICS. INSTALL ALL EQUIPMENT, PIPING IN ACCORDANCE WITH <br /> �� LOCAL AND NATIONAL CODES AND IN CONFORMANCE WITH GOOD <br /> Of <br /> O 4.8 COOLER DISPLAY DOORS SHALL HAVE 3-PANE HEATED SAFETY GLASS PRACTICE REQUIRED FOR PROPER OPERATION. <br /> D w <br /> U `N <br /> z <br /> N <br /> �i LO <br /> `o Project Number <br /> o � <br /> I <br /> SPA16002.0 <br /> U <br /> W <br /> z7 Sheet Name <br /> Q 23'-016 <br /> of 516„ 1 <br /> 0 23'-7" 9'-2" COOLER <br /> 0 <br /> PACKAGE <br /> 02 COOLER DIMENSION PLAN <br /> 0 - SCALE: 1/4"=1'-0" <br /> W <br /> a <br /> Sheet Number <br /> z <br /> W <br /> 0 <br /> z <br /> W <br /> a- <br /> Q1 <br /> 2 <br /> o ■ <br /> z <br />
The URL can be used to link to this page
Your browser does not support the video tag.