COLD WATER MAIN. ROBISON <br /> INDIRECT WASTE ROOF DRAIN OVERFLOW DRAIN2" EXTERNAL ENGINEERING, INC <br /> WATER DAM 19401 40TH AVE W.,SUITE 302 <br /> LYNNWOOD,WA 98036 <br /> HALF EXPOSED WATER PROOFING SHUT-OFF VALVE 206.364.3343 TEL <br /> WITH GROUT FILLED AT 45° MEMBRANE DO�� <br /> UNION CONTACT:MARK MANGLICMOT <br /> FINISHED FLOOR _ <br /> INSULATION--m--_ RIGID FOAM 1/2 <br /> INSULATION TRAP PRIMER VALVE <br /> 0' X 2 MIN. AIRGAP ROOF TP-1 ROFESS/p� <br /> I r STRUCTURE _ _ 0• Rpe��� <br /> 0.25" MINIMUM r0Z��, <br /> GROUT AND FLOORING BASE -� FLOOR TROUGH/GRATE VACUUM BREATHER E5 o. M-28712 Z <br /> FLUSHED WITH FINISHED FLOOR PORTS. 70 <br /> FIN. FLOOR - 0-19 <br /> oa000 NOTES: <br /> 0 0 0 0 4 1. PLUMBING CONTRACTOR SHALL COORDINATE WITH STRUCTURAL 1/2" FD-1 <br /> ENGINEER AND ROOFING CONTRACTOR FOR ROOF DRAIN LOCATION AND OF CALIF <br /> DIRECT CONNECTION INSTALLATION REQUIREMENTS. Seal 03-22-18 <br /> TO GREASED WASTE 2. ROOF DRAIN SHALL BE TOP CONNECT AND SUPPORT FROM NEAREST <br /> JOIST AND GIRDER. IF THERE ARE TWO ROOF DRAINS AT THE SAME ®® <br /> LOCATION, LOCATE ON ONTO BOTH SIDE OF JOIST OR GIRDER. SEWER GASES s 1e � <br /> FLOOR SINK SHALL BE EASILY AND FULLY ACCESSIBLE FOR CLEANING. 3. PROVIDE CLAMPING EXTENSION COLLAR TO ACCOMMODATE RIGID FOAM v <br /> MOUNT FLOOR SINK FLUSH TO FINISHED FLOOR ONLY AT THE CUSTOMER SIDE. INSULATION. �� e <br /> RAISE FLOOR SINK PER DETAIL ABOVE AT THE OPERATION SIDE. <br /> FLOOR SINK DETAIL N.T.S. 7 ROOF DRAIN DETAIL #1 N.T.S. 4 TRAP PRIMER DETAIL N.T.S. 1 <br /> CW SUPPLY <br /> ET-1 <br /> Q <br /> EXPANSION TANK <br /> OD <br /> CEMENT BED TILE FLOOR Cn <br /> HWS CONCRETE FILL <br /> z � <br /> O a- <br /> V) w <br /> �—� > o <br /> LU <br /> �=1 I=CI 7 Il II E ISI� _ CD <br /> f ei HWRCP-1 HWR a C� pOo� - - ao°p 000 <br /> FINISH FLOOR TO 0o <br /> LANDSCAPE OR FINISH m <br /> �� a SURFACE 00 <br /> �� _ - - - - _ �� Q <br /> T a a CO <br /> T&P RELIEF VALVE z <br /> DRAIN LINE 4 0o f� �� moo 00 <br /> EWH-1 — FOR CONTINUATION REFER y w <br /> _ 4 TO CIVIL ENGINEER pSD � T Q N <br /> DRAWINGS CPO 0) i <br /> I CD <br /> C�� PLATFORM ABOVE MOP SINK Q <br /> NO-HUB COUPLING , _SEAL <br /> a a a a a a a a <br /> TERMINATE DRAIN CONCRETE SLAB - ATTACHMENT <br /> LINE ABOVE MOP a <br /> SEALANT <br /> SINK WITH 2" AIR DRAIN TERMINATE ABOVE MOP WATERPROOF <br /> GAP MEMBRANE <br /> SINK WITH 2" AIR GAP <br /> 0 <br /> Q <br /> O =5 <br /> fr WATER HEATER SCHEMATIC DETAIL N.T.S. 8 N.T.S. N.T.S. LU 0- W M <br /> ROOF DRAIN DETAIL #2 5 FLOOR DRAIN DETAIL 2 w > �, <br /> DDo <br /> AS CLOSE AS POSSIBLE 7M 0) <br /> Z <br /> NOTE: W <br /> WATER HEATER STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD (1/3) AND Q O U <br /> LOWER ONE-THIRD (1/3) OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM # J <br /> DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. Q <br /> O w W <br /> NO-HUB COUPLING w <br /> LU <br /> SEALANT U V J �j !�1 z <br /> FLEXIBLE CONNECTION. ROOF/OVERFLOW a OVERFLOW NOZZLE 6" STANDPIPE v, v Q <br /> 3/4" TEMPERATURE DRAIN a (ZURN ZANB199 OR EQUAL) O Q <br /> AND PRESSURE RELIEF a - 1 z <br /> VALVE DRAIN PIPE TO SPLASHBLOCK N �.J <br /> BE TERMINATED ABOVE 1/4"X3" LAG SCREW GYPSUM WALLBOARD FLOOR SLAB W <br /> MOP SINK. WITH WASHER Cn <br /> 6" MINIMUM a FLOOR <br /> 3/4" PERFORATED ° °o o°°.° ° <br /> 24 GAUGE STEEL TAPE G8 II III III a <br /> O ° WALL TRAP PRIMER <br /> ,0 Project Number <br /> TV <br /> ® 1/4"X5" LAG I`b �� . 4" P-TRAP <br /> SCREW 6 >> SPA16002.0 <br /> PLATFORM ABOVE 3/4" PERFORATED <br /> MOP SINK 24 GAUGE STEEL TAPE ,L ^\5 <br /> � Sheet Name <br /> 1 1/2 <br /> WOOD 2"X4"LEDGER C-4 <br /> N <br /> PLUMBING <br /> FRONT VIEW TOP VIEW DETAILS <br /> CONCRETE SPLASHBLOCK <br /> 2 <br /> Sheet Number <br /> SEISMIC STRAPPING DETAIL N.T.S. 9 ROOF OVERFLOW DETAIL #3 N.T.S. 6 STANDPIPE DETAIL N.T.S. 3 P6m 1 <br />