My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CRESTWOOD
>
2056
>
1600 - Food Program
>
PR0546092
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2020 5:01:47 PM
Creation date
8/11/2020 2:58:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546092
PE
1617
FACILITY_ID
FA0024277
FACILITY_NAME
ARCO AM/PM-ASP PETROLEUM
STREET_NUMBER
2056
STREET_NAME
CRESTWOOD
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
2056 CRESTWOOD AVE
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
!Pi;lp% <br /> GAS/ELECTRIC PACKAGE ROOFTOP UNIT SCHEDULE LEGEND <br /> COOLING CONDENSING HEATING INDOOR FAN ELECTRICAL DATA SYMBOL ABBREVIATION DESCRIPTION <br /> MARK MANUFACTURER MODEL SERVICE NOMINALTOTAL SENSIBLE ENT. AIR ENT. AIR SEER MBH MBH %INPUT OUTPUT AFUE WEIGHT MIN. OUTSIDE <br /> LOCATION REMARKS <br /> MANUFACTURER/ <br /> # TONS MBH MBH DB, °F WB, °F EER IEER TEMP., `F CFM ESP BHP VOLTS PHASE FREQ. COMPR. MCA MOCP (LBS.) AIR CFM <br /> IN.WG. (HP) (Hz) RLA SA/SUP SUPPLY AIR (RISE/DROP) <br /> RTU "YORK" ZH090N12 STORE 7.5 93.0 70.0 80.0 67.0 11.5 12.7 95 120.0 96.0 80 3,000 0.8 2.03 208 3 60 11.9 57.9 60.0 1,000 400 ROOF 1 2 3 4 5 6 7 8 9 10 11 RA/RET RETURN AIR DUCT (RISE/DROP) ROBISON <br /> 1I I I I EA/EXH EXHAUST AIR DUCT (RISE/DROP) ENGINEERING, INC <br /> RTU "YORK" ZH061NO8 STORE 5.0 61.0 46.0 80.0 67.0 11.8 14.0 95 80.0 65.0 81 2,000 0.8 0.94 208 3 60 14.1 32.5 45.0 1,000 400 ROOF 1 2 3 4 5 6 7 8 9 10 11 CEILING DIFFUSER/SUPPLY REGISTER <br /> 19401 40TH AVE W.,SUITE 302 <br /> 2 -® - CD/SR (ARROWHEAD REPRESENTS NUMBER OF THROW) LYNNWOOD,WA 98036 <br /> s ( 4-WAY TYPICAL IF NO ARROWS) 206-364.3343 TEL <br /> RTU "YORK" ZH102N12 FUTURE TENANT 8.5 107.0 74.9 80.0 67.0 11.8 12.7 95 120.0 96.0 80 3,400 0.8 1.87 208 3 60 12.2 53.1 60.0 1,200 400 ROOF 1 2 3 4 5 6 7 8 9 11 <br /> CONTACT:MARK MANGLICMOT <br /> 3 ® -+� RR/RG RETURN REGISTER/GRILLE <br /> RTU "YORK" ZH102N12 FUTURE TENANT 8.5 107.0 74.9 80.0 67.0 11.8 12.7 95 120.0 96.0 80 3,400 0.8 1.87 208 3 60 12.2 53.1 60.0 1,200 400 ROOF 1 2 3 4 5 6 7 8 9 11 ER/EG EXHAUST REGISTER/GRILLE <br /> 4 <br /> RECTANGULAR DUCT ELBOW WITH TURNING VANES OFESS/pN <br /> 1 GAS HEATING ELECTRIC COOLING PACKAGED ® DUCT SMOKE DETECTOR IN SUPPLY AIR ® PROVIDE THE FOLLOWING FACTORY INSTALLED OPTIONS: 10 FACTORY INSTALLED POWER EXHAUST. _� FC FLEXIBLE CONNECTION U. RO F <br /> O ROOFTOP UNIT. PLENUM. A. 12" HIGH ROOF CURB. <br /> B. COMPRESSOR HARD START KIT. 11 DISCONNECT SWITCH. �- (L) DUCT LINING (1" THICK UNLESS OTHERWISE NOTED) <br /> O2 HIGH EFFICIENCY, STANDARD INDOOR FAN, LOW O5 PROVIDE PROGRAMMABLE THERMOSTAT. C. CRANKCASE HEATER. I SINGLE LINE DUCT BRANCH TAKE-OFF ,Z; o. M-28712 <br /> HEAT TYPE ROOFTOP UNIT D. FILTER RACK KIT. DUCT TRANSITION (RECTANGULAR TO ROUND) - 0-19 <br /> © R-410 REFRIGERANT. E. DUAL 115V GFCI CONVENIENCE OUTLET. <br /> SET O REQUMINIMUM REMENT. RTU FRESH SET FOR 400R CFM EACH UNIT. O7 MERV 8 FILTERS O9 ECONOMIZER FLEX FLEXIBLE DUCT (4'-0 MAXIMUM) .S�9TFFpF CA�F���\P <br /> T T-STAT PROGRAMMABLE THERMOSTAT <br /> Seal 03-22-18 <br /> S TEMPERATURE SENSOR <br /> Ca+ CO2 SENSOR <br /> EXHAUST FAN SCHEDULE GENERAL NOTES sD SD DUCT SMOKE DETECTOR <br /> Rf� MD MECHANICAL DAMPER ®� <br /> 0 DIA. DIAMETERAw <br /> ®_ <br /> EXHAUST EXT. STATIC ELECTRICAL DATA 1. CONSTRUCTION TO CONFORM WITH: FURNISHED AND INSTALLED BY MECHANICAL <br /> MARK SERVICE LOCATION AIR PRESSURE RPM WEIGHT MANUFACTURER & MODEL # REMARKS O CONTRACTOR. <br /> MOTOR - 2016 CALIFORNIA BUILDING CODE, WITH LOCAL AMENDMENTS <br /> CFM IN. W.G. WATTS VOLTS PHASE Hz LBS. - 2016 CALIFORNIA MECHANICAL CODE, WITH LOCAL AMENDMENTS O FURNISHED AND INSTALLED BY ELECTRICAL <br /> AMM W� <br /> - 2016 CALIFORNIA PLUMBING CODE. WITH LOCAL AMENDMENTS CONTRACTOR. <br /> KEF TYPE 2 ROOF 650 0.500 1 .270 (1/3) 115 1 60 95 "CAPTIVEAIRE" DU33HFA 3 4 5 7 8 9 - 2016 CALIFORNIA ELECTRICAL CODE, WITH LOCAL AMENDMENTS ME FURNISHED BY MECHANICAL CONTRACTOR AND ® � <br /> 1 HOOD - 2016 CALIFORNIA FIRE CODE, WITH LOCAL AMENDMENTS INSTALLED BY ELECTRICAL CONTRACTOR. <br /> EF - - 2016 CALIFORNIA ENERGY CODE, WITH LOCAL AMENDMENTS <br /> 1 <br /> RESTROOMS CEILING 220 0.250 48 115 1 60 24 "GREENHECK" SP-A200 1 2 3 ® - 2016 CALIFORNIA GREEN BUILDING STANDARDS CODE P.O.C. POINT OF CONNECTION <br /> EF SLUSH „ 2. THE CONTRACTOR IS RESPONSIBLE FOR PERMIT' FEES. FLEXIBLE DUCT <br /> MACHINE ROOF 500 0.375 936 (1/4) 115 1 60 11 „CAPTIVEAIRE DR30HFA 3 4 5 O7 <br /> 3. THE CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR, EQUIPMENT, <br /> TRANSPORTATION AND SERVICES NECESSARY FOR COMPLETION OF THE WORK. SD-1 (SD-SUPPLY DIFFUSER, RD-RETURN DIFFUSER, E-EXHAUST) <br /> CEILING MOUNTED EXHAUST FAN. O MUSHROOM TYPE FAN. Og PROVIDE POSITIVE INTERLOCK BETWEEN KEF-1 ALL MATERIALS AND WORK SHALL COMPLY WITH APPLICABLE CODES AND <br /> AND HP-1/HP-2 OUTSIDE AIR DAMPERS. GOVERNING REGULATIONS AND MEET THE APPROVAL OF THE LOCAL 100 AIR QUANTITY IN CFM <br /> O2 INTERLOCK WITH LIGHT FIXTURE. © SPEED CONTROLLER. OUTSIDE AIR DAMPERS SHALL OPEN WHEN JURISDICTION. <br /> KEF-1 IS ENERGIZED. AC MECHANICAL EQUIPMENT DESIGNATION <br /> O3 WITH BACKDRAFT DAMPER. O7 PROVIDE WITH 12" ROOF CURB. 4. ANY MATERIAL, ARTICLE OR PIECE OF EQUIPMENT OTHER THAN THAT <br /> INDICATED SHALL NOT BE USED UNLESS APPROVED IN WRITING BY THE 1 DESIGNATED NUMBER <br /> ® WITH FLEXIBLE DUCT CONNECTION. ® DISCONNECT SWITCH. ENGINEER AND ANY CHANGES IN MECHANICAL, ELECTRICAL AND/OR OTHER <br /> SYSTEMS REQUIRED DUE TO SUCH SUBSTITUTION SHALL BE THE A/C , AC AIR CONDITIONING m <br /> RESPONSIBILITY OF THE HVAC CONTRACTOR; AND AT NO ADDITIONAL COST TO BDD BACK DRAFT DAMPER cn <br /> THE OWNER. <br /> AIR DEVICE SCHEDULE w <br /> CB CIRCUIT BREAKER O <br /> 5. TAKE ALL PRECAUTIONS NECESSARY TO PROTECT THE MATERIALS BEFORE, w <br /> CLG. CEILING <br /> DURING AND AFTER INSTALLATION. IN THE EVENT OF DAMAGE, IMMEDIATELY <br /> TYPE MOUNTING DUTY REPAIR ALL DAMAGED AND DEFECTIVE WORK TO THE APPROVAL OF THE CONN. CONNECT/CONNECTION z <br /> DIFFUSER FACE ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. o <br /> CONT. CONTINUATION <br /> NECK OR CFM w w v >_ z Cn bi 6. THREE SETS OF OPERATING AND MAINTENANCE MANUALS SHALL BE CONT'R CONTRACTOR m <br /> MARK CEILING GRID U w w z a J o cn MFR. MODEL NO. REMARKS SUBMITTED UPON COMPLETION OF PROJECT. J <br /> SIZE RANGE cn J > LL 0- D Q z <br /> SIZE (INCHES) � 5 J r � a = Q CFM CUBIC FEET PER MINUTE Q <br /> o 0 of N U) Of w 7. IN ADDITION TO EQUIPMENT WARRANTIES, FURNISH A WRITTEN GUARANTEE <br /> AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE YEAR. CU CONDENSING UNIT z <br /> SD-1 8"� 12"x12" 0-190 X - - - X - X - - - TITUS PAS 1 2 3 GUARANTEE SHALL INCLUDE REPAIR OF DAMAGE TO, OR REPLACEMENT OF, DET. DETAIL CO <br /> ANY PART OF EQUIPMENT OR PREMISES CAUSED BY EQUIPMENT PROVIDED. <br /> DISC. DISCONNECT Q N <br /> SD-2 12"0 24"x24" 200-470 X - - - X - X - - - TITUS PAS O2 3 DTR DOWN THRU ROOF <br /> 0 <br /> 18"b 325-550 X X X TITUS T <br /> <G - - - - - - - MR 1 2 (E) EXISTING EF EXHAUST FAN <br /> a aaaaaaa <br /> RG-1 - PER DWGS PER DWGS <br /> SD-3 10" - - X - X - - X - - TITUS 50-F 2 3 <br /> E.A.T. ENTERING AIR TEMPERATURE <br /> TG-1 - PER DWGS PER DWGS - - X - X - - X - - TITUS 50-F O GA. GAGE/GAUGE <br /> GC GENERAL CONTRACTOR <br /> O1 PROVIDE OPPOSED BLADE DAMPER. GF GAS FURNACE <br /> O TYPE AND CFM SHALL BE AS INDICATED ON DRAWING HVAC HEATING, VENTILATING, AND AIR CONDITIONING <br /> 1/M-2.1 AT EACH AIR DEVICE. NC SHALL BE 35 OR LESS. <br /> O SELECTION OF THE FINISHES OF AIR DISTRIBUTION MCA MINIMUM CIRCUIT AMPACITY Q <br /> DEVICES BY INTERIOR DESIGNER/ARCHITECT. MFR. MANUFACTURER O W <br /> MECH. MECHANICAL <br /> AIR CURTAIN SCHEDULE MOCP MAXIMUM OVERCURRENT PROTECTION 0- w M <br /> FAN ELECTRICAL ACOUSTICS DIMENSIONS (in) (N) NEW ' ' O Q LO <br /> MARK MANUFACTURER & SERVICE MEASURE 10 FROM WEIGHT REMARKS OA/OSA OUTSIDE AIR 7� fr 0) <br /> MODEL MAX. FPM MAX. CFM MOTORS FLA VOLTAGE PHASE Hz NOZZLE LENGTH DEPTH (LBS) PH PHASE dRA QL I'Y1 P- O Q <br /> 1�ACN MARS RAD RETURN AIR DUCT � Q O U <br /> PH1072-2 3,950 2,920 TWO 1/2 10.2 115 1 60 MAIN DOOR 68 72 26 105 1 2 SAD SUPPLY AIR DUCTM� # J <br /> S/S STAINLESS STEEL P1r1 W U <br /> TYP. TYPICAL O w W <br /> O1 MICROSWITCH CONTROL. MOUNT SWITCH SUCH THAT UON UNLESS OTHERWISE NOTED U 3: U z <br /> AIR CURTAIN STARTS WHEN DOOR OPENS. <br /> UTR UP THRU ROOF LL Q <br /> O SELECTION OF THE FINISHES OF AIR CURTAIN BY <br /> V VOLTS Q <br /> INTERIOR DESIGNER/ARCHITECT. z <br /> U Q <br /> w <br /> DRAWING SCHEDULE co <br /> SHEET NUMBER DESCRIPTION <br /> MOA EQUIPMENT SCHEDULES, LEGEND & NOTES <br /> MO.2 MECHANICAL SPECIFICATIONS <br /> Project Number <br /> M2.1 MECHANICAL FLOOR PLAN SPA16002.0 <br /> M2.2 MECHANICAL ROOF PLAN <br /> M2.3 MECHANICAL ROOF PLAN (FUTURE TENANT) Sheet Name <br /> M6.1 MECHANICAL DETAILS EQUIP. SCHED. <br /> M6.2 HOOD & FANS SHOP DRAWING LEGEND, NOTES <br /> M9.1 CONTROLS <br /> Sheet Number <br /> M001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.