Laserfiche WebLink
DOORS & HARDWARE DRINKING FOUNTAINS WALKS AND SIDEWALKS ACCESSIBILITY SIGNAGE <br /> 1. ALL ENTRANCES AND EXTERIOR GROUND-FLOOR EXIT DOORS TO BUILDINGS AND FACILITIES SHALL BE 1. INTERNATIONAL SYMBOL OF ACCESSIBILITY:THE FOLLOWING ELEMENTS AND SPACES OF ACCESSIBLE <br /> MADE ACCESSIBLE TO PERSONS WITH DISABILITIES.DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING 1. THE FLOW OF WATER SHALL BE ACTIVATED BY A MANUALLY OPERATED SYSTEM THAT IS FRONT MOUNTED OR SIDE 1. CONTINUOUS SURFACE:WALKS AND SIDEWALKS SUBJECTTO THESE REGULATIONS SHALL HAVE A FACILITIES SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY: <br /> OF 32 INCHES WITH THE DOOR OPEN 90 DEGREES,MEASURED BETWEEN THE FACE OF THE DOOR AND MOUNTED AND LOCATED WITHIN 6 INCHES OF THE FRONT EDGE OF THE FOUNTAIN OR AN AUTOMATIC CONTINUOUS COMMON SURFACE,NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL <br /> THE OPPOSITE STOP(SECTIONS 1008.1.1, 11 B-404.2 AND 11 B-404.2.3). ELECTRICALLY CONTROLLED DEVICE.CBC 11 B-602.3 EXCEEDING 1/2 INCH AND SHALL BE A MINIMUM OF 48 INCHES IN WIDTH.LEVEL CHANGES GREATER THAT 1/4 A. ACCESSIBLE PARKING SPACES. ■ <br /> INCH AND UP TO 112 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2(PER SECTION 11 B-303.2 ARCHITECTURE <br /> 2. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 34 INCHES AND 44 INCHES 2. THE SPOUT SHALL BE LOCATED 15 INCHES MINIMUM FROM THE VERTICAL SUPPORT AND 5 INCHES MAXIMUM FROM AND 11 B-303.3).SURFACES SHALL BE SLIP RESISTANT AS FOLLOWS:(SECTION 11 B-302.1). B. ACCESSIBLE AREA OF REFUGE. <br /> ABOVE THE FLOOR.LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A THE FRONT EDGE OF THE UNIT,INCLUDING BUMPERS PER CBC 11 B-602.5 <br /> PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER-TYPE HARDWARE,PANIC BARS, A. SLOPES LESS THAN 6 PERCENT:SLIP-RESISTANT AS DESCRIBED FOR A MEDIUM SALTED FINISH. C. ACCESSIBLE PASSENGER LOADING ZONES. <br /> PUSH-PULL ACTIVATING BARS,OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT 3. THE SPOUT SHALL PROVIDE A FLOW OF WATER 4 INCHES HIGH MINIMUM AND SHALL BE LOCATED 5 INCHES <br /> MAXIMUM FROM THE FRONT OF THE UNIT.THE ANGLE OF THE WATER STREAM SHALL BE MEASURED B. SLOPES 6 PERCENT OR GREATER:SHALL BE SLIP-RESISTANT. <br /> REQUIRING THE ABILITY OT GRASP THE OPENING HARDWARE.LOCKED EXIT DOORS SHALL OPERATE AS D. ACCESSIBLE TOILET AND BATHING FACILITIES. <br /> ABOVE IN EGRESS DIRECTION (SECTIONS 1008.1.9 AND 11 B-404.2.7). HORIZONTALLY RELATIVE TO THE FRONT FACE OF THE UNIT PER CBC 11 B-602.6 <br /> C. SURFACE CROSS SLOPES:SHALL NOT EXCEED 1:48 E. ALL MAIN ENTRY DOORS. <br /> 3. PANIC HARDWARE:WHERE INSTALLED,SHALL COMPLY WITH THE REQUIREMENTS OF CBC 1008.1.10.1.THE 4. WHERE THE SPOUTS ARE LOCATED LESS THAN 3 INCHES OF THE FRONT OF THE UNIT THE ANGLE OF THE WATER ARCHITECT <br /> STREAM SHALL BE 30 DEGREES MAXIMUM PER CBC 11 B-602.6 1. GRATINGS:WALKS,SIDEWALKS,AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER POSSIBLE. <br /> ACTIVATING MEMBER SHALL BE MOUNTED AT A HEIGHT OF NOT LESS THAN 34 INCHES OR MORE THAN FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS,GRID OPENINGS IN GRATINGS SHALL BE 1. OTHER SIGNS:INACCESSIBLE BUILDING ENTRANCES,INACCESSIBLE PUBLIC TOILETS AND BATHING FACILITIES, NJ ASSOCIATES <br /> 44 INCHES ABOVE THE FLOOR.THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED AND ELEVATORS NOT ON AN ACCESSIBLE ROUTE SHALL BE PROVIDED WITH DIRECTIONAL SIGNAGE INDICATING <br /> IN THE DIRECTION OF TRAVEL.(SECTION 1008.1.10, 1008.1.10.1,AND 11 B-404.2.9). 5. WHERE THE SPOUTS ARE LOCATED BETWEEN 3 INCHES AND 5 INCHES MAXIMUM FROM THE FRONT OF THE UNIT, LIMITED TO 1/2"(13 MM) IN THE DIRECTION OF TRAFFIC FLOW(SECTION 11 B-302.3). THE ROUTE TO THE NEARST SIMILAR ACCESSIBLE ELEMENT(SECTIONS 11 B-216.3, 11 B-216.6 AND 11 B-216.9.2)) 22769 N BENDER ROAD <br /> THAN ANGLE OF THE WATER STREAM SHALL BE 15 DEGREES MAXIMUM PER CBC 11 B-602.6 6 THE SPOUT OUTLETS ACAMPO CA 95220 <br /> 4. WIDTH AND HEIGHT:EVERY REQUIRED EXIT DOORWAY SHALL BE OF A SIZE AS TO PERMIT THE OF DRINKING FOUNTAINS FOR STANDING PERSONS SHALL BE 38 INCHES MINIMUM AND 43 INCHES MAXIMUM 2. CHANGES IN LEVEL:ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2 A. AT EXITS SERVING A REQUIRED ACCESSIBLE SPACE,BUT NOT PROVIDING AN APPROVED ACCESSIBLE MEANS 209.727.2040 <br /> ABOVE THE FINISHED FLOOR OR GROUND PER CBC 11 B-602.7 7 WALL AND POST MOUNTED CANTILEVERED INCH.WHEN CHANGES IN LEVEL DO OCCUR,THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAT 1 <br /> INSTALLATION OF A DOOR NOT LESS THAN 3 FEET IN WIDTH AND NOT LESS THAN 6 FEET,8 INCHES IN OF EGRESS,SIGNS SHALL BE INSTALLED INDICATING THE LOCATION OF ACCESSIBLE MEANS OF EGRESS. www.njaarchitecture.com <br /> HEIGHT WHEN INSTALLED IN EXIT DOORWAYS.EXIT DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DRINKING FOUNTAINS SHALL BE 18 INCHES MINIMUM AND 19 INCHES MAXIMUM IN DEPTH PER CBC 11 B-602.8 8 THE UNIT VERTICAL IN 2 UNITS HORIZONTAL.EXCEPTTHAT LEVEL CHANGES NOT EXCEEDING 1/4 INCH MAY BE (SECTION 11 B-216.4.3) <br /> DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE EXIT WAY IS NOT LESS THAN 32 PROTECTED AREA WITHIN WHICH A DRINKING FOUNTAIN IS LOCATED SHALL BE 32"WIDE MINIMUM AND 18 INCHES VERTICAL.WHEN CHANGES IN LEVELS GREATER THAN 1/2 INCH ARE NECESSARYTHEY SHALL COMPLY WITH <br /> INCHES(SECTIONS 1008.1.1 AND 11 B-404.2.). DEEP MINIMUM AND SHALL COMPLY WITH CBC 11 B-305.7 THE REQUIREMENTS FOR CURB RAMPS(SECTION 11 B-303.4). 1. DESIGN:THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO INDENTIFY CLIENT <br /> FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN THESE <br /> 5. HINGED DOORS:THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN ANGLE 3. WARNING CURBS:ABRUPT CHANGES IN LEVEL,EXCEPT BETWEEN A WALK OR SIDEWALK AND AN ADJACENT BUILDING STANDARDS AND AS SPECIFICALLY REQUIRED IN THESE NOTES(SECTION 11 B-703.7.2.1). HIGH WATER BREWING <br /> OF 90 DEGREES FROM ITS CLOSED POSITION.WHERE A PAIR OF DOORS IS UTILIZED,AT LEAST ONE OF THE STREET OR DRIVEWAY,EXCEEDING 4 INCHES IN A VERTICAL DIMENSION,SUCH AS AT PLANTERS OR <br /> SHALL BE SIDEWALKS OR OTHER PEDESTRIAN WAYS, <br /> DOORS SHALL MEET THIS OPENING REQUEMENT.REVOLVING DOORS SHALL NOT BE USED AS A REQUIRED FOUNDATIONS LOCATED IN OR ADJACENTTO WAKS, 2. COLOR OF SYMBOL:THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE <br /> ENTRANCE FOR PERSONS WITH DISABILITIES(SECTIONS 11 B-404.2.1, 11 B-404.2.2 AND 11 B-404.2.3). INDENTIFIED BY CURBS PROJECTING AT LEAST 6 INCHES IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE BACKGROUND.THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595B.(SECTION <br /> TO WARN THE BLIND OF A POTENTIAL DROP OFF.WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED,NO CURB 11 B-703.7.2.1)A.EXCEPTION:THE APPROPRIATE ENORCEMENT AGENCY MAY APPROVE SPECIAL SIGNS AND <br /> 6. THE MAXIMUM WIDTH OF A SWINGING DOOR LEAF SHALL NOT EXCEED 48 INCHES(SECTION 1008.1.1). IS REQUIRED WHEN A GUIDE RAIL IS PROVIDED CENTERED 2 INCHES MINIMUM AND INCHES MAXIMUM IDENTIFICATION NECESSARY TO COMPLEMENT DECOR OR UNIQUE DESIGN WHEN IT IS DETERMINED THAT <br /> BATHING AND TOILET FACILITIES ABOVE THE SURFACE OF THE WALK OR SIDEWALK.(SECTION 11 B-303.5). SUCH SIGNS AND IDENTIFICATION PROVIDE ADEQUATE DIRECTION TO PERSONS WITH DI SABI LITI ES.(S ECTION <br /> 7. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR EXTERIOR DOORS AND 5 11 B-703.7.2.1,EXCEPTION) <br /> POUNDS FOR INTERIOR DOORS,SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO 1. PASSAGEWAYS LEADING TO SANITARY FACILITIES SHALL HAVE A CLEAR ACCESS AS SPECIFIED IN SECTION 4. PROVIDE A LEVEL AREA NOT LESS THAN REQUIRED(TABLE AND FIGURE 11 B-404.2.4.1). PROJECT <br /> HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS.COMPENSATING DEVICES 11 B-402.ALL DOORWAYS LEADING TO SUCH SANITARY FACILITIES SHALL HAVE: 3. CONTRAST AND FINISH:CHARACTER AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND OR DARK HIGH WATER BREWING <br /> OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEETTHE ABOVE STANDARDS.WHEN FIRE 5. WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5 FEET IN LENGTH AT INTERVALS CHARACTERS ON A LIGHT BACKGROUND.THE(FINISH OF)CHARACTERS AND BACKGROUND OF SIGNS SHALL BE <br /> DOORS ARE REQUIRED,THE MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED NOTTO A. AN UNOBSTRUCTED CLEAR OPENING WIDTH OF 32 INCHES(813 MM). OF 400 FEET MAXIMUM(SECTION 11 B-403.7). EGGSHELL,MATTE,OR OTHER NON-GLARE FINISH(SECTION 11 B-703.5.1 AND 11 B-703.7.1). 927 INDUSTRIAL WAY <br /> LODI CA 95240 <br /> EXCEED 15 POUNDS(SECTIONS 1008.1.3, 1008.1.3.1 AND 11 B-404.2.9). 6. A 36 INCH WIDE DETECTABLE WARNING MATERIAL SHALL BE PROVIDED AT BOUNDARIES BETWEEN <br /> B. A LEVEL AND CLEAR AREA NOT LESS THAN REQUIRED(TABLE AND FIGURE 11 B-404.2.4.1) 4. PROPORTIONS:CHARACTERS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER <br /> 8. DOOR AND GATE SURFACES:SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FINISH WALKWAYS AND VEHICULAR WAYS. MATERIAL SHALL COMPLY WITH SECTION 11 B-705.1.1 "0"IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER"I" <br /> FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACES ON THE PUSH SIDE 1. BATHING FACILITIES(NOT APPLICABLE). (SECTION 11 B-703.5.4). <br /> EXTENDING THE FULL WIDTH OF THE DOOR OR GATE.PARTS CREATING HORIZONTAL OR VERTICAL <br /> JOINTS IN THESE SURFACES SHALL BE WITHIN 1/16" INCH OF THE SAME PLANE AS THE OTHER AND BE 2. TOILET FACILITIES(SECTION 11 B-603). 5. CHARACTER HEIGHT:MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH TABLE 11 B-703.5.5.VIEWING <br /> FREE OF SHARP OR ABRASIVE EDGES.CAVITIES CREATED BY ADDED KICK PLATES SHALL BE CAPPED DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN <br /> (SECTIONS 11 B-404.2.10). A. MULTIPLE-ACCOMMODATION TOILET FACILITITIES SHALL HAVE THE FOLLOWING: OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN.CHARACTER HEIGHT SHALL BE BASED <br /> 9. THRESHOLDS SHALL NOT EXCEED 1/2 INCHES IN HEIGHT,WITH A MAXIMUM 1/4-INCH VERTICAL AND a. CLEAR SPACE:A WATER CLOSET FIXTURE LOCATED IN A COMPARTMENT SHALL PROVIDE A MINIMUM <br /> LOCKERS ON THE UPPERCASE LETTER"I"(SECTION 11 B-703.5.5). <br /> CHANGES IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER 17 INCHES AND 18 INCHES MAXIMUM FROM THE CENTERLINE OF THE WATER CLOSET TO THE WALL, 1. AT LEAST ONE LOCKER AND NOT LESS THAN 5%OF ALL LOCKERS SHALL BE MADE ACCESSIBLE TO PERSONS 6. WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES,RAISED LETTERS SHALL ALSO BE <br /> THAN 1:2(50%SLOPE) (SECTION 11 B-404.2.5). EXCEPT THAT THE WATER CLOSET SHALL BE A MINIMUM 17 INCHES AND 19 INCHES MAXIMUM FROM WITH DISABILITIES.(SECTION 11 B-225.2.1) PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE(SECTION 11 B-703.2). <br /> THE CENTERLINE OF WATER CLOSETTO THE WALL IN AMBULATORY ACCESSIBLE TOILET <br /> 10. EXIT DOORS FROM GROUP'A'OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT COMPARTMENTS.A MINIMUM 48 INCHES LONG CLEAR SPACE SHALL BE PROVIDED IN FRONT OF THE 2. A CLEAR FLOOR SPACE OF AT LEAST 30 INCHES BY 48 INCHES THAT ALLOWS EITHER A FORWARD OR PARALLEL 7. RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS:WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, <br /> IS PANIC HARDWARE(SECTION 1008.1.10). WATER CLOSET IF THE COMPARTMENT HAS AN END-OPENING DOOR(FACING THE WATER CLOSET).A APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED.(SECTION 11 B-305) THEY SHALL CONFORM TO THE FOLLOWING REQUIREMENTS(11 B-703.2 AND 11 B-703.4). <br /> MINIMUM 60 INCH LONG CLEAR SPACE SHALL BE PROVIDED IN A COMPARTMENT WITH THE DOOR <br /> 11. RECESSED DOORMATS SHALL BE ADEQUATELY ANCHORED TO PREVENT INTERFERENCE WITH LOCATED AT THE SIDE AND OPENING OUT.GRAB BARS SHALL NOT PROJECT MORE THAN 3 INCHES IN 3. HEIGHT:FOR FORWARD APPROACH,THE MAXIMUM HIGH FORWARD REACH SHALL BE 48 INCHES AND THE A. CHARACTER TYPE:LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32 INCH MINIMUM AND SHALL BE <br /> WHEELCHAIR TRAFFIC(SECTION 11 B-302.1 AND 11 B-302.2). THE CLEAR SPACES AS SPECIFIED ABOVE. MINIMUM LOW FORWARD REACH IS 15 INCHES..FOR PARALLEL APPROACH,THE MAXIMUM HIGH SIDE REACH SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.(SECTION 11 B-703.2.1, <br /> 12. ALL GATES,INCLUDING TICKET GATES,SHALL MEET ALL APPLICABLE SPECIFICATIONS FOR DOORS b. COMPARTMENT DOORS:WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITHA DOOR THAT HAS SHALL BE 48 INCHES AND THE LOW SIDE REACH SHALL BE MINIMUM 15 INCHES ABOVE THE FLOOR.(SECTION 11 B-703.2.3 AND 11 B-703.3)11 B-308) <br /> (SECTION 11 B-404.1 AND 11 B-404.2). AN AUTOMATIC-CLOSING DEVICE,AND SHALL HAVE A CLEAR,UNOBSTRUCTED OPENING WIDTH OF 32 B. CHARACTER SIZE:RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8 INCH HIGH TO A <br /> INCHES WHEN LOCATED ATTHE END AND 34 INCHES WHEN LOCATED ATTHE SIDE WITH THE DOOR 4. HARDWARE:LATCH&LOCKING HARDWARE SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE MAXIMUM HEIGHT OF 2 INCHES.(SECTION 11 B-703.2.5) <br /> 13. DOOR CLOSING SPEED:DOOR AND GATE CLOSING SPEED SHALL COMPLY WITH SECTION 11 B-404.2.8. POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION(SECTION 11 B-604.8.1.2).3 THE TIGHT GRASPING,PINCHING OR TWISTING OF THE WRIST.THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL <br /> DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U-SHAPED BE NO GREATER THAN 5 POUNDS OF FORCE.(SECTION 11 B-309.4) C. PICTORIAL SYMBOL SIGNS(PICTOGRAMS NONGEOMETRIC):PICTORIAL SYMBOL SIGNS(PICTOGRAMS) <br /> DEGRESS,THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 HANDLE IMMEDIATELY BELOW THE LATCH,MOUNTING HEIGHT OF 34 INCHES TO 44 INCHES A.F.F.THE SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE <br /> SECONDS MINIMUM.DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN LATCH SHALL BE FLIP-OVER STYLE,SLIDING,OR OTHER HARDWARE NOT REQUIRING THE USER TO PICTOGRAM.THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6 INCHES IN HEIGHT. <br /> POSITION OF 70 DEGREES,THE DOOR OR GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS GRASP OR TWIST.EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS,A CLEAR,UNOBSTRUCTED (SECTION 11 B-703.6.1) <br /> MINIMUM.(SECTIONS 11 B-404.2.8.1 AND 11 B-404.2.8.2). ACCESS OF NOT LESS THAN 44 INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS <br /> DESIGNED FOR USE BY PERSONS WITH DISABILITIES AND THE SPACE IMMEDIATELY IN FRONT OF A D. CHARACTER PLACEMENT:CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT.BRAILLE SHALL <br /> 14. THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC- WATER CLOSET COMPARTMENT SHALL NOT BE LESS THAN 48 INCHES(1219 MM)AS MEASURED AT BE PLACED A MINIMUM OF 3/8 INCH AND A MAXIMUM OF 1/2 INCH DIRECTLY BELOW THE TACTILE <br /> CLOSING DEVICE,AND SHALL HAVE A CLEAR,UNOBSTRUCTED OPENING WIDTH OF 34 INCHES. RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSED POSITION. BLEACHERS CHARACTERS(FLUSH LEFT OR CENTERED).WHEN TACTILE TEXT IS MULTILINED,ALL BRAILLE SHALL BE <br /> PLACED TOGETHER BELOW ALL LINES OF TACTILE TEXT.(SECTION 11 B-703.3.2) <br /> 15. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR U- 1. GRAB BARS <br /> SHAPED HANDLE IMMEDIATELY BELOW THE LATCH.THE LATCH SHALL BE FLIP-OVER STYLE,SLIDING OR 1. BLEACHERS,GRANDSTANDS AND FOLDING AND TELESCOPIC SEATING,THAT ARE NOT BUILDING ELEMENTS,SHALL 1. BRAILLE:CONTRACTED(GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER <br /> OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. A. LOCATION:GRAB BARS LOCATED ON EACH SIDE,OR ONE SIDE AND THE BACK OF THE ACCESSIBLE TOILET COMPLY WITH ICC 300 PER CBC 1028.1.1 PORTIONS OF THESE STANDARDS.DOTS SHALL BE 1/10 INCH ON CENTER IN EACH CELL WITH 2/10 INCH SPACE <br /> STALL OR COMPARTMENT,SHALL BE SECURELY ATTACHED 33 INCHES MINIMUM AND 36 INCHES MAXIMUM BETWEEN CELLS DOTS SHALL BE RAISED A MINIMUM OF 1/40 INCH ABOVE THE BACKGROUND.BRAIL DOTS <br /> 16. EXCEPTION:IN GROUPS A,DIVISION 3,B,F,M,AND S OCCUPANCIES AND IN ALL CHURCHES,KEY-LOCKING ABOVE AND PARALLEL TO THE FLOOR.SIDE GRAB BARS SHALL BE 42 INCHES MINIMUM LOCATED 12 INCHES SHALL BE DOMED OR ROUNDED(TABLE 11 B-703.3.1). <br /> HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR MAXIMUM FROM REAR WALL,EXTENDING 54 INCHES MINIMUM FROM THE REAR WALL WITH THE FRONT <br /> PAIR OF DOORS IF THERE IS A READILY VISIBLE,DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING END POSITIONED 24 INCHES IN FRONT OF THE WATER CLOSET STOOL.REAR GRAB BARS SHALL BE 36 2. MOUNTING LOCATION AND HEIGHT:WHERE PERMANENT IDENTIFICATION SIGNS ARE PROVIDED FOR ROOMS <br /> "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS".THE SIGN SHALL BE IN LETTERS NOT LESS INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF WATER CLOSET 12 INCHES MINIMUM ON AND SPACES,SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR ON THE <br /> THAN 1 INCH ON A CONTRASTING BACKGROUND.WHEN UNLOCKED,THE SINGLE DOOR OR BOTH LEAVES ONE SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE(SECTIONS 11 B 609.4., 11 B-604.5.1 AND APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE.WHERE THERE IS NO WALL SPACE ON <br /> OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE.THE USE 11 B-604.5.2). THE LATCH SIDE,INCLUDING AT DOUBLE LEAF DOORS,SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT <br /> OF THIS EXCEPTION MAY BE REVOKED BY THE BUILDING OFFICIAL[FOR HCD 1&21 ENFORCING AGENCY SANITARY FACILITIES IDENTIFICATION WALL,PREFERABLY ON THE RIGHT.SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SOTHAT A <br /> FOR DUE CAUSE. B. DIAMETER OR WIDTH:THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL BE CLEAR FLOOR SPACE OF 18 INCHES MINIMUM BY 18 INCHES MINIMUM,CENTERED ON THE TACTILE <br /> 1-1/4 INCHES TO 2 INCHES(32 MM TO 38 MM)OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING 1. DOORWAYS LEADING TO MEN'S SANITARY FACILITIES SHALL BE INDENTIFIED BY AN EQUILATERAL TRIANGLE 1/4 CHARACTERS,IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 <br /> 17. EXIT DOORS SHALL BE FURNISHED&INSTALLED WITH HARDWARE ALLOWING DOOR TO BE OPENED SURFACE.IF GRAB BARS ARE MOUNTED ADJACENT TO A WALL,THE SPACE BETWEEN THAT WALL AND GRAB INCH THICK WITH EDGES 12 INCHES LONG AND A VERTEX POINTING UPWARD.WOMEN'S SANITARY FACILITIES DEGREE OPEN POSITION.TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES MINIMUM ABOVE THE <br /> FROM THE INSIDE WITHOUTTHE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT.PAIRS OF EXIT BARS SHALL BE 1-1/2 INCHES(38 MM).SEE FIGURE 11 B-609.2.2(11 B-609.2). SHALL BE IDENTIFIED BY A CIRCLE,1/4 INCH THICK AND 12 INCHES IN DIAMETER.UNISEX SANITARY FACILITIES FINISH FLOOR OR GROUND SURFACE,MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 <br /> DOORS SHALL BE FURNISHED&INSTALLED WITH APPROVED AUTOMIAC FLUSH BOLTS ON ONE OF THE SHALL BE IDENTIFIED BY A CIRCLE 1/4 INCH THICK, 12 INCHES IN DIAMETER WITH A 1/4 INCH THICKTRIANGLE INCHES MAXIMUM ABOVE FINISH FLOOR OR GROUND SURFACE,MEASURED FROM THE BASELINE OF THE ARCHITECTS STAMP <br /> DOOR LEAVES AND NO SURFACE MOUNTED HARDWARE INSTALLED ON SAME LEAF.THE UNLATCHING OF C. STRUCTURAL STRENGTH:THE STRUCTURAL STRENGTH OF GRAB BARS,TUB AND SHOWER SEATS, SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER.THESE GEOMETRIC SYMBOLS SHALL BE HIGHEST LINE OF RAISED CHARACTERS.(SECTION 11 B-703.4.1 AND 11 B-703.4.2). <br /> BOTH DOOR LEAVES SHALL NOT REQUIRE MORE THAN ONE OPERATION. FASTENERS,AND MOUNTING DEVICES SHALL MEET THE REQUIREMENTS IN SECTIONS 11 B-609.8.GRAB BARS CENTERED ON THE DOOR AT A HEIGHT OF 60 INCHES AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY <br /> SHALL NOT ROTATE WITHIN THEIR FITTINGS.(SECTION 11 B-609.6) DIFFERENT FROM THE COLOR AND CONTRAST OF THE DOOR. 3. ENTRANCE SIGNS:ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH SE A <br /> DISABILITIES SHALL BE INDENTIFIED WITH AT LEAST ONE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN AND <br /> D. SURFACE:A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENTTO IT SHALL BE FREE OF ANY SHARP 2. SEE ACCESSIBLITY SIGNAGE CRITERIA FOR ADDITIONAL REQUIREMENTS. WITH ADDITIONAL DIRECTIONAL SIGNS(UTILIZING THE SYMBOL),AS REQUIRED ATJUNCTIONS WHERE THE <br /> OR ABRASIVE ELEMENTS.EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8 INCH (3.2 MM).(SECTION ACCESSIBLE ROUTE OF TRAVEL DIVERGES FROM THE REGULAR CIRCULATION PATH,TO BE VISIBLE TO PERSONS -� JOHN A VIERRA <br /> 11 B-609.5) ALONG APPROACHING CIRCULATION PATHS.(SECTION 11 B-216.6) * C-35199 <br /> 10-31-2019 <br /> DATE <br /> 1. TOILET ROOM FIXTURES AND ACCESSORIES <br /> RAMPS A. LAVATORY FIXTURES:A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES SHALL BE PROVIDED IN FRONT OF A �0 CAS-NFA <br /> LAVATORYTO ALLOW A FORWARD APPROACH.SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN <br /> ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 INCHES INTO KNEE AND TOE SPACE <br /> 1. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1 FOOT OF VERTICAL UNDERNEATH THE LAVATORY.(SECTIONS 11 B-305.3 AND 11 B-306.2.2,EXCEPTION) REVISIONS <br /> RISE IN 20 FEET OF HORIZONTAL RUN(5%GRADIENT).THE LEAST POSSIBLE SLOPE SHALL BE USED FOR ANY <br /> RAMP(SECTION 11 B-405.2). B. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 40 No. Description Date By <br /> INCHES FROM THE FLOOR.MIRRORS NOT LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE <br /> 2. WIDTH:PRIMARY ENTRANCE AND SPECIAL OCCUPANCY,PEDESTRIAN RAMPS SERVING PRIMARY ENTRANCES MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTIVE SURFACE NO HIGHER THAN 35 INCHES FROM THE <br /> TO BUILDINGS HAVING AN OCCUPANT LOAD OF 300 OR MORE SHALL HAVE A MINIMUM CLEAR IN WIDTH FLOOR(SECTION 11 B-603.3). <br /> OF 60 INCHES.RAMPS SERVING GROUP R OCCUPANCIES MAY BE 36 INCHES CLEAR WIDTH WHEN THE <br /> OCCUPANT LOAD IS 50 OR LESS.ALL OTHER PEDESTRIAN RAMPS SHALL HAVE A MINIMUM WIDTH OF 48 C. WHERE TOWEL,SANITARY NAPKINS„WASTE RECEPTACLE,AND OTHER SIMILAR DISPENSING AND DISPOSAL <br /> INCHES(SECTION 11 B-405.5). FIXTURES ARE PROVIDED,AT LEAST ONE OF EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, <br /> 3. SLOPE:THE MAXIMUM SLOPE OF A RAMP THAT SERVES ANY EXIT WAY THAT PROVIDES ACCESS FOR INCLUDING COIN SLOTS,WITHIN 40 INCHES FROM THE FINISHED FLOOR(SECTION 11 B-603.5). <br /> PERSONS WITH PHYSICAL DISABILITIES OR IS IN THE PATH OF TRAVEL SHALL BE 1 FOOT OF VERTICAL RISE IN D. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL WITHIN 7-9 INCHES OF THE FRONT EDGE OF Project No.: 17043 <br /> 12 FEET OF HORIZONTAL RUN (8.3%MAX.GRADIENT) (SECTION 11 B-405.2).THE CROSS SLOPE OF RAMP THE TOILET SEAT,MOUNTED BELOW THE GRAB BAR,AT A MINIMUM HEIGHT OF 19 INCHES.DISPENSERS Drawn By: Author <br /> SURFACES SHALL BE NO GREATER THAN 1 UNIT VERTICAL IN 48 UNITS HORIZONTAL(SECTION 11 B-405.3). THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED.LIMIT Checked By: Checker <br /> THE PROJECTION OF A SURFACE OR SEMI-RECESSED MOUNTED DISPENSER FROM ENCROACHING MORE <br /> 4. A CURB,2 INCHES HIGH MINIMUM,OR BARRIER SHALL BE PROVIDED THAT PREVENTS THE PASSAGE OF A 4 THAN 3 INCHES FROM THE FACE OF THE WALL OR PARTITION,AND NO CLOSER THAN 1-1/2 INCHES TO THE <br /> INCH DIAMETER SPHERE,WHERE ANY PORTION OF THE SPHERE IS WITHIN 4 INCHES OF THE FINISH FLOOR TANGENT POINT OF THE GRAB BAR(SECTION 11 B-604.7). <br /> OR GROUND SURFACE.TO PREVENT WHEEL ENTRAPMENT,THE CURB OR BARRIER SHALL PROVIDE A NOT FOR CONSTRUCTION <br /> CONTINUOUS AND UNINTERRUPED BARRIER ALONG THE LENGTH OF THE RAMP. E. WHERE URINALS ARE PROVIDED,AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE 30 INCHES BY 48 <br /> INCHES IN FRONT OF THE URINAL TO ALLOW FORWARD APPROACH (SECTION 11 B-605.3). PERMIT SET <br /> 04.04.18 <br /> ACCESSIBILITY STANDARDS <br /> G5 a <br /> 0 <br /> v <br /> m • <br /> 0 <br /> N <br /> R <br />