My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
744
>
1600 - Food Program
>
PR0529790
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2020 3:29:09 PM
Creation date
8/11/2020 3:24:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0529790
PE
1619
FACILITY_ID
FA0019653
FACILITY_NAME
Smart Final #393
STREET_NUMBER
744
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
CURRENT_STATUS
01
SITE_LOCATION
744 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
159'-8" <br />40'-8"80'-0"39'-0" <br />9'-0"19'-10"11'-2"8'-10"19'-10"11'-4"183'-11"210'-7"25'-4"40'-0"40'-0"40'-0"38'-7"26'-8"8'-4"18'-4"9'-3"1PROPOSED REFLECTED CEILING PLANSCALE1/8" = 1' - 0"DSCHEDULE OF KEYED NOTESSCALEN/ACGENERAL NOTESSCALEN/AALEGENDSCALEN/A70015/8" GYP. BD. CEILING OVER METAL STUD FRAMED CEILING; PAINT. (RE: A8.0-A)7002SURFACE MOUNTED LIGHT FIXTURES (RE: ELECTRICAL DWGS)7003SUSPENDED LIGHT FIXTURE. (RE: ELECTRICAL DRAWINGS)7004WIRE MESH ENCLOSURE ABOVE COOLER BOX TO THE BOTTOM OF THE ROOFSTRUCTURE. (TYPICAL AT STORAGE) (RE: DETAIL A4.1-25)7006TYPE 1 HOOD FOR OVEN BELOW. (RE: MECHANICAL DRAWINGS)7007OVERHEAD, ILLUMINATED EXIT SIGNAGE. (RE: ELECTRICAL DRAWINGS)7005PROVIDE AIR CURTAIN W/ STEEL CAGE. (RE: MECHANICAL DRAWINGS)7008(E) PROTOCOL UNIT ABOVE COOLER BOXGENERAL NOTES:A.PRIOR TO START OF CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ALLDIMENSIONS ON SITE AND EXISTING CONDITIONS. ANY DISCREPANCIES FOUND ONSITE SHALL BE REPORTED TO THE ARCHITECT OR SMART & FINAL CONSTRUCTIONMANAGER BEFORE PROCEEDING WITH THE WORK.B.KEEP ALL BACKROOM REFRIGERATION LINES, FIRE SPRINKLER LINES, PLUMBINGLINES, CONDUIT, ETC. IN WEB JOISTS OR TIGHT TO BOTTOM OF ROOF STRUCTURE.C.KEEP ALL OVERHEAD REFRIGERATION LINES, FIRE SPRINKLER LINES, PLUMBING LINES,CONDUIT, ETC. IN WEB JOISTS OR TIGHT TO BOTTOM OF STRUCTURE AT MAIN SALESAREAS.ARCHITECTURAL:A.ALL SUSPENDED WALL / SOFFIT / CELING HEIGHTS ARE BOTTOM OF STRUCTURE,UNLESS OTHERWISE INDICATED. WHERE NEW CONSTRUCTION OCCURS, ALIGNSURFACES WITH EXISTING TRIM & ADJUST DIMENSIONS & HEIGHTS TO COORDINATEWITH INTENDED ALIGNMENT OR RELATIONSHIPS.B.FOR SUSPENDED WALL FRAMING AND BRACING. (RE: A4.0-14 & 19)C.CLEAN ALL ROOF FRAMING THAT ARE EXPOSED TO PUBLIC VIEW WHICH INCLUDESBEAMS, PURLINS, AND ALL ASSOCIATED ROOF HARDWARE AND CONNECTORS.D.PAINT ALL INTERIOR GYP. BD. CEILINGS, SOFFITS, BOTTOM & BACK SIDES OF ALLSUSPENDED WALLS.E.PATCH AND CLEAN EXISTING CEILING TO REMAIN AS REQUIRED WHERE DAMAGED ANDWHERE MECHANICAL AND ELECTRICAL MODIFICATIONS HAVE OCCURRED (I.E. LIGHTREMOVAL), AND WHERE FOUND DEFECTIVE DURING CONSTRUCTION.STRUCTURAL:A.PROVIDE LATERAL BRACING AT SUSPENDED CEILING SYSTEMS W/ (4) #12GA WIRE TIEDTO STRUCTURE & SECURED TO MAIN RUNNER WITHIN 2" OF CROSS RUNNER, SPLAYED90 DEGREES FROM EA. OTHER AT 45 DEGREES TO CEILING PLANE. PLACE BRACING AT12'-0" EA. WAY & WITHIN 4'-0" OF PERIMETER WALLS. LATERAL BRACING SHALL CONFORMTO ASTM STANDARDS C635 & C636.MECHANICAL:A.G.C. SHALL CLEAN THE (E) REGISTERS AND DUCTS, PERFORM NECESSARYINSPECTIONS AND NOTIFY SMART AND FINAL OF THE NUMBER OF DETERIORATINGAND NON-OPERABLE UNITS. SUCH UNITS SHALL BE REPAIRED OR REPLACED UPONSMART AND FINAL'S APPROVAL.ELECTRICAL:A.CONTRACTOR SHALL STRAIGHTEN, CLEAN AND RE-LAMP ALL EXISTING LIGHT FIXTURES(INTERIOR AND EXTERIOR), CAMERAS, SPEAKERS, ETC. AND PERFORM NECESSARYINSPECTION AND NOTIFY SMART & FINAL OF THE NUMBER OF DETERIORATING,NON-OPERABLE UNITS. (RE: ELECTRICAL DRAWINGS)FIRE PROTECTION:A.THE DESIGN-BUILD BIDDING FIRE SPRINKLER CONTRACTOR AND GENERALCONTRACTOR ARE REQUIRED TO VISIT THE STORE DURING THE BID PERIOD AND MAKEFIELD OBSERVATIONS OF WHAT WILL BE REQUIRED TO VISIT THE STORE DURING THEBID PERIOD AND MAKE FIELD OBSERVATIONS OF WHAT WILL BE REQUIRED TO MODIFYTHE EXISTING FIRE SPRINKLER SYSTEM TO ACCOMMODATE THIS REMODEL SCOPE ORWORK. FIRE SPRINKLER SUBCONTRACTOR IS ALSO REQUIRED TO NOTE AND INCLUDEANY AND ALL EXISTING CONDITIONS THAT WILL NEED TO BE REMEDIED TO BRING THEEXISTING FIRE SPRINKLER SYSTEM TO CURRENT FIRE DEPARTMENT, OR OTHERAUTHORITIES REQUIREMENTS. NO CHANGE ORDER WILL BE ACCEPTED BY SMART &FINAL FOR WORK REQUIRED BY THE FIRE DEPARTMENT INSPECTION DURINGCONSTRUCTION RELATED TO BRINGING THE EXISTING FIRE SPRINKLER SYSTEM TOCURRENT AUTHORITIES REQUIREMENTS.B.CONTRACTOR SHALL CLEAN EXISTING SPRINKLER HEADS AND REPLACE MISSINGESCUTCHEONS, INTERIOR AND EXTERIOR.BEGRESS NOTESSCALEN/A1.THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED ATALL TIMES THE BUILDING SPACE SERVED BY MEANS OF EGRESS IS OCCUPIED. THEMEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLEAT THE WALKING SURFACE LEVEL. (CBC 1006.1 & 1006.2)2.EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OFAN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE ANINTENSITY OF NOT LESS THAN 5 FOOT-CANDLES (54 LUX). INTERNALLY ILLUMINATEDSIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCEWITH THE MANUFACTURER'S INSTRUCTIONS AND CHAPTER 27. EXIT SIGNS SHALL BEILLUMINATED AT ALL TIMES. (CBC SECTION 1011).3.THE MEANS OF EGRESS ILLUMINATION AND EXIT SIGNS SHALL BE CONNECTED TO ANEMERGENCY ELECTRICAL SYSTEM THAT WILL PROVIDE AN ILLUMINATION OF NOT LESSTHAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS. THE INSTALLATION OF THEEMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH CHAPTER 27. (CBC1006.3 & 1011.5.3)4.CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOMOR AREA SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THEOUTLET BOX NOR LESS THAN 15" MEASURED FROM THE BOTTOM OF THE OUTLET BOXTO THE LEVEL OF FINISH FLOOR. (CBC 1117B.6.5.1)COOLER / FREEZER WALLSUSPENDED CEILINGGYP. BD. CEILINGKEYED NOTES####(N) EXTERIOR WALL(E) LIGHT FIXTURERECESSED LIGHT FIXTUREILLUMINATEDEMERGENCY EXIT SIGNLINE OF WIRE MESH(N) INTERIOR WALLEXTERIOR WALL PACKCOOLER PANEL CEILING(N) LIGHT FIXTUREOPEN TO STRUCTURE7001700470057006700870087008Filename:Sheet Title:Date:Scale:Project No.: Drawn By:Reviewed By:No.MCG ARCHITECTS 2018 ALL RIGHTS RESERVEDCSheet #:09-18-18Description18.452DateRevisions:Client:A Project for:Seal:TEAM600 CITADEL DRIVE,COMMERCE, CA 90040Tel. (323) 869 7500Fax (323) 869 7856TENANT IMPROVEMENT <br />STOCKTON, CA 95207 <br />SMART & FINAL #393 <br />744 WEST HAMMER LANE <br />AS NOTED10.22.181ST SUBMITTALA7.0REFLECTEDCEILING PLAN
The URL can be used to link to this page
Your browser does not support the video tag.