My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GOLDEN VALLEY
>
16514
>
1600 - Food Program
>
PR0544910
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:15:33 AM
Creation date
8/12/2020 8:15:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0544910
PE
1625
FACILITY_ID
FA0025530
FACILITY_NAME
IN-N-OUT BURGER #346
STREET_NUMBER
16514
STREET_NAME
GOLDEN VALLEY
STREET_TYPE
PKWY
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16514 GOLDEN VALLEY PKWY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
750
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In-N-Out Burgers NGF 255 Progate Drive Thru Service Manual <br />© 2011, IMI Cornelius Inc.- 17 -Publication Number: 621058475SER <br />Sanitize syrup lines, B-I-B Systems <br />1. Remove all the quick disconnects from all the B-I-B containers. <br />2. Fill a suitable pail or bucket with soap solution. <br />3. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle brush. <br />(Do not use a wire brush). Rinse with clean water. <br />4. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution. <br />5. Rinse the B-I-B disconnects in the sanitizing solution. <br />6. Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings are not available, the fittings from <br />empty B-I-B bags can be cut from the bags and used. These fittings open the disconnect so the sanitizing solu- <br />tion can be drawn through the disconnect. <br />7.Place all the B-I-B disconnects into the pail of sanitizing solution. Operate all the valves until the sanitizing solu- <br />tion is flowing from the valve. Allow sanitizer to remain in lines for fifteen (15) minutes. <br />8. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse with clean <br />water and reassemble the nozzle and syrup diffuser to the valve. <br />9.Remove the sanitizing fittings from the B-I-B disconnects and connect the disconnects to the appropriate <br />B-I-B container. Operate the valves until all sanitizer has been flushed from the system and syrup is flowing <br />freely. <br />Replenishing CO2 Supply (As Required) <br />NOTE: When indicator on the 1800-psi gage is in the shaded (“change CO2 cylinder”) portion of the <br />dial, CO2 cylinder is almost empty and should be changed. <br />1. Fully close (clockwise) the CO2 cylinder valve. <br />2. Slowly loosen the CO2 regulator assembly coupling nut allowing CO2 pressure to escape, then remove the <br />regulator assembly from the empty CO2 cylinder. <br />3. Unfasten safety chain and remove the empty CO2 cylinder. <br />!WARNING: <br />To avoid personnel injury and/or property damage, always secure the CO2 cylinder with a safety chain to prevent it <br />from falling over. Should the valve become accidently damaged or broken off, a CO2 regulator can cause serious <br />personnel injury or death could occur. <br />4. Position the full CO2 cylinder and secure with a safety chain. <br />5. Make sure gasket is in place inside the CO2 regulator assembly coupling nut, then install the regulator assem- <br />bly on the CO2 cylinder. <br />6. Open (counterclockwise) the CO2 cylinder valve slightly to allow the lines to slowly fill with gas, then open the <br />valve fully to back-seat the valve (back-seating the valve prevents gas leakage around the valve shaft). <br />7. Check CO2 connections for leaks. Tighten any loose connections.
The URL can be used to link to this page
Your browser does not support the video tag.