Laserfiche WebLink
In-N-Out Burgers NGF 255 Progate Drive Thru Installation Manual <br />© 2011, IMI Cornelius Inc.- 13 -Publication Number: 621058475INS <br />2. The LED meter turns ON once the programming mode is entered. Visual feedback of ratio/agitation time is <br />obtained from the visual programming LED. The LED meter shows the existing agitation ratio <br />enabling the user to. <br />3. Vary the agitation time using the directional arrow buttons. Left to decrease and right direction arrow button to <br />increase. <br />Ice Portion Bar <br />The portion bar is used to determine the amount of time programmed for each size button. Each button has a <br />minimum and maximum amount of time that can be programmed. If a button cannot be adjusted to the size desired <br />use another button to get the desired results. <br />Figure 10. <br /> <br />=20mS <br />50mS 230mS <br />“S” Small <br />80mS 260mS <br />“M” Medium <br />150mS 330mS <br />“L” Large <br />230mS 410mS <br />“XL” XLarge