In-N-Out Burger NGF 255 Progate Drive Operators Manual <br />© 2011, IMI Cornelius Inc.- 7 -Publication Number: 621058745INS <br />Product Tubing (Monthly Cleaning) <br />IMPORTANT: Only trained and qualified persons should perform these cleaning and sanitizing <br />procedures. <br />Sanitize Pre-Mix And Post–Mix Tank System <br />1. Remove all the quick disconnects from all the tanks. Fill a suitable pail or bucket with soap solution. <br />2. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle brush. <br />(Do not use a wire brush). Rinse with clean water. <br />3. Prepare sanitizing solution and using a mechanical spray bottle, spray the disconnects. <br />Allow to air dry. <br />4. Using a clean, empty tank, prepare five (5) gallons of the sanitizing solution. Rinse the tank disconnects with <br />approximately 9 oz. of the sanitizing solution. Close the tank. <br />5. Prepare cleaning tank by filling clean five (5) gallon tank with a mixture of mild detergent and potable water <br />(120oF). <br />6. Connect a gas disconnect to the tank and then apply one of the product tubes to the cleaning tank. Operate <br />the appropriate valve until liquid dispensed is free of any syrup. <br />7. Disconnect cleaning tank and hook up sanitizing tank to syrup line and CO2 system. <br />8. Energize beverage faucet until chlorine sanitizing solution is dispensed through the faucet. Flush at least two <br />(2) cups of liquid to ensure that the sanitizing solution has filled the entire length of the syrup tubing. <br />9. Allow sanitizer to remain in lines for fifteen (15) minutes. <br />10. Repeat the step above, applying a different product tube each time until all tubes are filled with the sanitizing <br />solution. <br />11. Remove the nozzle and syrup diffuser and clean them in a mild soap solution. <br />Rinse with clean water and reassemble the nozzle and syrup diffuser on the valve. <br />12. Rinse the parts in clean water, reassemble the valve and reconnect it to the dispenser. <br />13. Discard the tank of sanitizing solution and reconnect the product syrup tanks. Operate the valves until all sani- <br />tizer has been flushed from the system and only product syrup is flowing. <br />Sanitize syrup lines, B-I-B Systems <br />1. Remove all the quick disconnects from all the B-I-B containers. <br />2. Fill a suitable pail or bucket with soap solution. <br />3. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle brush. <br />(Do not use a wire brush). Rinse with clean water. <br />4. Using a plastic pail, prepare approximately five (5) gallons of sanitizing solution. <br />5. Rinse the B-I-B disconnects in the sanitizing solution. <br />6. Sanitizing fittings must be attached to each B-I-B disconnect. If these fittings are not available, the fittings from <br />empty B-I-B bags can be cut from the bags and used. These fittings open the disconnect so the sanitizing solu- <br />tion can be drawn through the disconnect. <br />7. Place all the B-I-B disconnects into the pail of sanitizing solution. Operate all the valves until the sanitizing solu- <br />tion is flowing from the valve. Allow sanitizer to remain in lines for fifteen (15) minutes. <br />8. Remove the nozzle and syrup diffuser from each valve and clean them in a soap solution. Rinse with clean <br />water and reassemble the nozzle and syrup diffuser to the valve. <br />9. Remove the sanitizing fittings from the B-I-B disconnects and connect the disconnects to the appropriate B-I-B <br />container. Operate the valves until all sanitizer has been flushed from the system and syrup is flowing freely.