Laserfiche WebLink
In-N-Out Burger NGF 255 Progate Drive Operators Manual <br />Publication Number: 621058745INS - 10 -© 2011, IMI Cornelius Inc. <br />3. Press the UP ARROW button to increase the amount of dispensed ice. The LED moves towards the <br />right indicating the Ice Portion has been increased. <br />4. Press the DOWN ARROW button to decrease the amount of dispensed ice. The LED moves towards the <br />left indicating the Ice Portion has been decreased. <br />5. To exit the program mode press the Desired Size button or wait 10 seconds and the control returns to the <br />dispense mode. <br />6. Place a cup under the ice chute and press the just programmed dispense size button If amount dispense <br />amount is not the desired amount repeat the process. <br />Agitation Time <br />The software coding for the progate system involves a direct relationship between the dispense time and the agitation time. <br />Dispense Rime <br />(mS)Agitation Ratio Agitation Time <br />(mS) <br />50 10 500 <br />70 10 700 <br />90 10 900 <br />110 10 1100 <br />130 10 1300 <br />150 10 1500 <br />170 10 1700 <br />190 10 1900 <br />210 10 2100 <br />230 10 2300 <br />Dispense Rime <br />(mS)Agitation Ratio Agitation Time <br />(mS) <br />50 16 800 <br />70 16 1120 <br />90 16 1440 <br />110 16 1760 <br />130 16 2080 <br />150 16 2400 <br />170 16 2720 <br />190 16 3040 <br />210 16 3360 <br />230 16 3680 <br />Dispense Rime <br />(mS)Agitation Ratio Agitation Time <br />(mS) <br />50 28 1400 <br />70 28 1960