1230A215-Mar2008 1330A215-Mar2008 <br />A. GENERAL: Safe and satisfactory operation of a gas fryer depends on its proper installation. Installation must conform to local codes <br />or, in the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1 (latest edition). In Canada, gas installa- <br />tion shall be in accordance with the current CAN/CGA B 149.1 and .2 installation codes and/or local codes. <br /> Each gas fryer should be installed as follows: <br /> 1. Placed beneath a properly designed exhaust hood <br /> 2. Installed by a licensed plumber. <br /> 3. Connected to the type of gas for which the unit was fabricated as shown on the rating plate. <br /> 4. Connected to the proper size pressure regulator installed in the gas supply line and adjusted to the proper manifold pressure. <br /> 5. Connected to the main gas supply line with the proper size supply line. <br /> 6. Restrained by use of a restraining device to avoid splashing of hot liquid and to assure tension cannot be placed on the gas or <br />electrical connections. CLEARANCES: The appliance must be kept free and clear of all combustibles. The minimum clearance <br />from combustible and non-combustible construction is 6" (152 mm) from the sides, and 6" (152 mm) from rear. The fryer may <br />be installed on combustible floors. <br /> NOTE: Adequate clearances must be provided for servicing and proper operation. <br />B. STANDARDS: Installation must be planned in accordance with all applicable state and local codes, taking into account the following <br />standards: <br /> 1. The fryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of <br />that system at pressures in excess of 1⁄2 psig (3.45kPa). In Canada, gas installation shall be in accordance with the current CAN/ <br />CGA B 149.1 and .2 installation codes and/or local codes. <br /> 2. The fryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure <br />testing of the gas supply piping system at pressures equal to or less than 1⁄2 psig (3.45kPA). <br /> 3. When installed the fryer must be electrically grounded in accordance with local codes, or in the absence of local codes, in <br />accordance with the current National Electrical code ANSI/NFPA 70 (latest edition). In Canada electrical installation must be in <br />accordance with the current Canadian Electrical Code CSA C22.1 and CSA C22.2 as applicable. <br /> 4. Other applicable nationally recognized installation standards such as: <br /> a. National Fuel Gas Code ANSI Z223.1 (latest edition) <br /> American Gas Association <br /> 1515 Wilson Blvd. <br /> Arlington, VA22209 <br /> b. NFPA Standards #54, #94 and #221 (latest edition) <br /> National Fire Protection Association <br /> 470 Atlantic Avenue <br /> Boston, MA 02110 <br /> c. ANSI Z21.69/CAN/CGA-6.16 AND Z21.41/CAN1 6.9 <br /> 5. Exhaust hood, when installed must conform to the current NFPA 54-1 and Canadian CAN/CGA-1.11 (latest edition) <br /> NOTE: Local building codes will usually not permit a fryer with its open tank of hot oil to be installed immediately next to an <br /> open flame of any type, whether a broiler or an open burner or range. Check local codes before beginning installation. <br />C. AIR SUPPLY AND VENTILATION: The area around the appliance must be kept clear of any combustible or flammable products and <br />avoid any obstruction to the flow of ventilation air as well as for ease of maintenance and service. NOTHING is to be stored in <br />the interior of the fryer’s cabinet except the filter tub assembly. <br /> 1. A means must be provided for any commercial, heavy duty-cooking appliance to exhaust combustion wastes outside of the <br />building. It is essential that a fryer be set under a powered exhaust hood or that an exhaust fan be provided in the wall above the <br />unit, as exhaust temperatures are in the vicinity of 400˚F (204˚C). <br /> WARNING <br />Strong exhaust fans in a hood or in the overall air conditioning system can produce slight air drafts in the room, which <br />can interfere with burner performance and be hard to diagnose. Air movement should be checked during installation <br />and if burner problems persist, make-up air openings or baffles may have to be provided in the room. <br /> 2. Exhaust temperature, in addition to the open tank of hot oil, make the storage of anything on shelving over or behind the fryer <br />unsafe. <br /> 3. Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and installing any <br /> hood. <br /> 4. Provisions must be made for an adequate supply of fresh air and adequate clearance must be maintained for air openings into the <br />combustion chamber. <br />