GENERAL NOTES A] <br /> A. REFERENCE SPECIFICATIONS AND DETAILS ON SHEETS M1.0 AND M5.0 Architecture / Development <br /> TOP OF PARAPET RESPECTIVELY, FOR ROOFTOP EQUIPMENT INSTALLATION AND CONNECTION <br /> TOP OF PARAPET IS 19'-10" DETAILS. <br /> IS 19'-10" 14901 Quorum Drive <br /> B. REFERENCE GENERAL NOTES ON SHEET M2.0 PRIOR TO COMMENCING Suite 300 <br /> CONSTRUCTION. Dallas Texas 75254 <br /> Ph: 972)239- 84 <br /> - - -t - _ - _ _ _ _ _ _ _ _ _ _ _ _ C. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES WHEN LOCATING Fax:((972)23988054 <br /> � - - - - - - - - - - - - - - - - �- - - - - - - - - - - - - - - - - - - - - - - - -�___�— �___ - - - - - - - - - - - - - - - ROOFTOP EQUIPMENT. <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ISSUE RECORD <br /> 1 1 O O FI D. PROVIDE PHENOLIC TAG, WITH 3/4" HIGH LETTERING, IDENTIFYING ROOF DATE DESCRIPTION <br /> L -1MOUNTED EQUIPMENT AND AREA IT SERVES. <br /> URBAN PROTOTYPE DESIGN <br /> 1 1 10-22-2018 ISSUED FOR PERMIT <br /> IIII 11 I1 11 I <br /> °I — n X n <br /> III 101 1 1 1 NOTES BY SYMBOL O <br /> ROOF <br /> 1 1 TOP OF PARAPET <br /> ACCESS - O� \_ O IS 19'-10" O REFERENCE 01/P1.1 FOR WATER HEATER DETAIL. <br /> 1 1 1 1 O5 1 02 KITCHEN HOOD EXHAUST FANS. EF-2 DOES NOT SERVE A TYPE I <br /> AC GREASE HOOD. <br /> I I I I <br /> 1 IL- - - _ - • • �4 3 MAINTAIN A DISTANCE OF 2 FT BETWEEN EXHAUST FANS AND <br /> L- -1 O PARAPET AND/OR SCREEN WALL. TOP OF DISCHARGE OPENING <br /> C 20 L • • / / • SHALL BE HIGHER THAN TOP OF PARAPET AND/OR SCREEN WALL. <br /> I I REVISION RECORD <br /> Q \ O DASHED CIRCLE REPRESENTS MINIMUM 10' CLEARANCE REQUIRED BY <br /> , I - -1- -�- - - - _ _ CODE BETWEEN EXHAUST OUTLET AND AIR INTAKE OPENINGS. <br /> 18 u /\ � O7 13 2 12 3 11 1 — <br /> - - N o� L / O5 PROPOSED LOCATION OF REMOTE CONDENSING UNIT FOR KITCHEN <br /> Of <br /> I EQUIPMENT. COORDINATE EXACT LOCATION AND LIMITS ON <br /> PROVIDE DUCT <br /> F1 Q U� L - - I GREASE EXHAUST RISER REFRIGERANT LINE LENGTHS WITH KITCHEN EQUIPMENT SUPPLIER. <br /> _ — - CLEANOUT AT TOP OF REFERENCE ARCHITECTURAL PLANS FOR ROOF PENETRATION <br /> I 1 I � 1 I � � � <br /> (TYPICAL) REQUIREMENTS. <br /> ?� A <br /> - -�- _ 01 Fc- (ABOVE) _ • TOP OF RTUAC L - O BATHROOM EXHAUST FAN. REFERENCE 11/M5.0 FOR DETAIL. <br /> -I - - - - IS 59" 2 EF \ O CONNECT RTU INTEGRAL DUCT-SMOKE DETECTOR TO FIRE ALARM <br /> - /' ABOVE ROOF �4 2 12 5" 10.5" DUC FROM SYSTEM AS REQUIRED. ACTUATION SHALL ACTIVATE A VISIBLE AND <br /> TYPICAL _ DECK • . • • // 11 �QYER HOOD _ AUDIBLE ALARM. DUCT SMOKE DETECTORS SHALL COMPLY WITH UL <br /> I SUPPORT REFRIGERANT LINES UP DOWN <br /> 2 FROM CU-1 ON ROOF. ROUTE � 1 �j/ �� L- 268A (ALL OTHERS WITH UL 268). INSTALL IN ACCORDANCE WITH <br /> PIPINGINCEILING TO CONNECTIONS / I� 5 -- EF NFPA 72. <br /> 1 AT FC 1. - / �� O 5 2 12 / O ALL REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL <br /> 8 9 10 _ TOP OF RTU J '� ' BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS. <br /> II - \ <br /> 1 O IS 59" • • G'Zb DUUI1� - 9"x6"I (� FROM ONI N 9 REFRIGERANT JOINTS ERECTED ON PREMISES SHALL BE EXPOSED TO PROFESSIONAL SEAL <br /> - REFERENCE 08/M5.0 \ ABOVE ROOF O7 13 r EXHA O <br /> FOR DETAIL / DECK x • ) VIEW FOR VISUAL INSPECTION PRIOR TO BEING COVERED OR <br /> FROM GlRinnENCLOSED. <br /> (TYPICAL OF 3) 10 REFRIGERATION SYSTEMS SHALL COMPLY WITH ASHRAE 15. Q <br /> 1 EF <br /> 0 <br /> TOP F \ 3 12 2 11 PROVIDE VENTILATED ROOF CURB. <br /> ACOCOESS - DECK IS ROOF _ Lem <br /> - <br /> 1 1 \ 13'-4' ACCESS 22 1 - - / 0 EXHAUST OUTLETS SHALL HAVE THE DISCHARGE OPENING LOCATED <br /> / EF NOT LESS THAN 40" ABOVE THE ROOF SURFACE. `� <br /> � VL _ <br /> I I ��� � � I III � �� <br /> 13 26-3/4"x34" (LINING=R5) SUPPLY AIR AND 46-7/8"x12-5/8" D , <br /> 1 ROOF 1 x ° GLI TOP OF PARAPET (LINING=R5) RETURN AIR VERTICAL DUCT FOR ROOFTOP UNIT AC-1 <br /> ACCESS D5 - J 15 Oo IS 19,-10" AND AC-2. <br /> LADDER V � I <br /> J 14 25-1/2x61-5/8" (LINING=R5) SUPPLY AIR AND 19-1/4"x68-1/8" <br /> - - - - AC I • / ' — � (LINING=R5) RETURN AIR VERTICAL DUCT FOR ROOFTOP UNIT AC-3 <br /> 1 TOP OF RTU <br /> 3 AB VE ROOF \ 15 COMBUSTION AIR CALCULATION <br /> • DEC O 399,998 BTU-H/4000 BTU-H=99.9 SQ. INCHES (2) 14" X 22" <br /> - t M <br /> F — / �_ F \� F -1 COMBUSTION AIR LOUVERS PROVIDED AT EACH LOCATION, SEE engineering consultants <br /> \ \ / \ / 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> \ / F ARCHITECTURAL ROOF PLAN A6.0. <br /> \ I �- J rtmassociates.com 1 972.387.3500 <br /> \ I I \/ I / 16 7.25"x7.25" \ - - - - - - - - - - - - - - L -1 16 PROVIDE 24"x24" DOOR LOUVER (MIN 50% FREE AREA BY G.C.) z <br /> 18.GHAA.03 <br /> ROOF / 17 COORDINATE ELECTRICAL ITEM TO BE INSTALLED IN THIS AREA AND <br /> ACCESS PROTOTYPE VERSION <br /> TO PROVIDE A 8 W x 6 H SIGN MOUNTED ON WALL NEXT TO DOOR. <br /> \ _ LADDER \ \ /// /' SIGN TO READ "CAUTION - CARBON DIOXIDE GAS". VENTILATE AREA URBAN DESIGN <br /> BEFORE ENTERING. <br /> \ 18 / /�� PROJECT NAME <br /> • - - J // / / / 18 6"0 B-VENT THRU ROOF WITH CAP, RAIN SHIELD AND WATERTIGHT <br /> FLASHING. IN-N-OUT <br /> O (TYPICAL OF 2) <br /> II <br /> � 18 /// /j j/ 19 NOT USED BURGER <br /> �TOOF PARAPET ' ' ' 20 NOT USED <br /> IS 19 <br />