ABBREVIATIONS PLUMBING LEGEND GENERAL NOTES
<br /> POINT OF CONNECTION 1. CONTRACTOR SHALL REFER TO SHEETS A1.A - A1.G FOR SPECIFICATIONS APPLICABLE TO ALL 25. BELOW GRADE OUTSIDE BUILDING, GAS PIPING MAY BE HIGH DENSITY POLYETHYLENE (HDPE)
<br /> ABV ABOVE SYMBOL DESCRIPTION SYMB0L DESCRIPTION PLANS. GENERAL NOTES SHALL APPLY TO ALL SHEETS, I.E. ALL WORK UNLESS NOTED PIPE WITH HEAT FUSION FITTINGS CONFORMING TO ASTM D2513 IF PERMITTED BY A.H.J. Architecture / Development
<br /> ADA AMERICANS WITH DISABILITIES ACT OTHERWISE (U.N.O.). INSTALLATION SHALL CONFORM TO LOCAL CODE AND UTILITY COMPANY REQUIREMENTS. PROVIDE
<br /> AFF ABOVE FINISHED FLOORPLASTIC PIPE WITH TRACER WIRE. 14901 Quorum Drive
<br /> AFG ABOVE FINISHED GRADE BALL VALVE 2. PLUMBING WORK SHALL INCLUDE FURNISHING, INSTALLING, AND TESTING ALL PLUMBING SYSTEMS,
<br /> 9 SYMBOL NOTE INCLUDING: PIPING, VALVES, DEVICES AND APPURTENANCES, AND EQUIPMENT FOR COMPLETE AND 26. CONNECTIONS, FITTINGS, ETC. SHALL BE SAME WEIGHT AS PIPE AND EQUAL TO PRODUCTS OF Suite 300
<br /> AHJ AUTHORITY HAVING JURISDICTION FULLY OPERATIONAL SYSTEMS. CONTRACTOR SHALL COORDINATE, INSTALL, AND TEST ITEMS CRANE COMPANY. VALVES SHALL CONFORM TO ASME 816.33. ONE INCH AND SMALLER Dallas Texas 75254
<br /> GATE VALVE & ANGLE GATE VALVE SPECIFICALLY NOTED AS FURNISHED BY OTHERS. WORK INCLUDES, BUT IS NOT LIMITED TO: VALVES SHALL BE LEVER HANDLE. LARGER VALVES SHALL BE IRON BODY WITH BRONZE
<br /> CD CONDENSATE DRAIN P-23 KITCHEN ITEM NUMBER SQUARE HEAD PLUG. PROVIDE OPERATING WRENCH WITH EACH VALVE. PROVIDE UNIONS AT Ph: (972)239-8884
<br /> CFH CUBIC FEET PER HOUR A. PIPING, FITTINGS, AND ESCUTCHEONS AT WALL PENETRATIONS,
<br /> EACH CONNECTION TO EQUIPMENT. DO NOT INSTALL UNIONS ELSEWHERE. Fax: (972)239-5054
<br /> CFM CUBIC FEET PER MINUTES SOLENOID VALVE % FD C. PLUMBING FIXTURES,
<br /> FLOOR DRAIN B. COPPER CONDENSATE DRAINS (REFER TO MECHANICAL PLANS TO COORDINATE), 27. GAS BRANCH LINES SHALL BE MADE WITH 45° AND 90° TEES OUT OF THE TOP OF MAINS. ISSUE RECORD
<br /> Cl CAST IRON q� D. COPPER CONDENSATE AND INDIRECT DRAINS FROM KITCHEN EQUIPMENT IN ACCORDANCE DATE DESCRIPTION
<br /> CHECK VALVE FS FLOOR SINK WITH EQUIPMENT MANUFACTURER'S DIRECTIONS, 28. PROVIDE A METAL LABEL FOR EACH GAS SHUT-OFF VALVE THAT IS NOT LOCATED ADJACENT TO
<br /> CLG CEILING THE EQUIPMENT IT SERVES. URBAN PROTOTYPE DESIGN
<br /> E. FAUCETS, DRAINS, AND CHROME-PLATED VALVES FOR MOP SINKS AND RESTROOM SINKS,
<br /> CO CLEANOUT 10-22-2018 ISSUED FOR PERMIT
<br /> F. WATER HEATERS AND TEMPERATURE / PRESSURE SAFETY RELEASE,
<br /> PRESSURE & TEMP RELIEF VALVE 29. CONTRACTOR SHALL INSTALL SOLENOID VALVE FOR KITCHEN GAS CONTROL, FURNISHED BY
<br /> CONT CONTINUATION DIRECTION OF SLOPE G. BACKFLOW PREVENTERS AT WATER FILTER, COFFEE/TEA MAKER, AND SODA DISPENSER AND KITCHEN EQUIPMENT VENDOR, AND WIRED BY FIRE SUPPRESSION SYSTEM CONTRACTOR.
<br /> CW COLD WATER DIRECTION OF FLOW VACUUM BREAKER AT EACH PIECE OF EQUIPMENT CONNECTED TO COLD WATER AND AS
<br /> DN DOWN �� REQUIRED BY LOCAL CODE, 30. PROVIDE U.L. LISTED CORRUGATED, FLEXIBLE GAS CONNECTIONS TO WATER HEATERS AND
<br /> BACKFLOW PREVENTER (BFPD-#) H. SHUT-OFF VALVES ON WATER AND GAS PIPES AT EACH BRANCH AND PIECE OF EQUIPMENT
<br /> PIPE UP COOKING EQUIPMENT CONFORMING TO ANSI 221.24. PROVIDE RIGID CONNECTIONS TO ALL
<br /> DFU DRAINAGE FIXTURE UNIT OR FIXTURE, OTHER EQUIPMENT AND APPLIANCES AND WHERE LOCAL CODE PROHIBITS THE USE OF FLEXIBLE
<br /> DIA DIAMETER ❑ D PIPE DOWN I. GAS PIPING (REFER TO MECHANICAL PLANS AND KITCHEN PLANS TO COORDINATE), CONNECTIONS. OUTDOOR CONNECTORS SHALL BE LISTED FOR OUTDOOR USE.
<br /> D DRAIN IFA FLOW ALARM J. PATCHING AND REPAIRING ALL AREAS DAMAGED DURING CONSTRUCTION.
<br /> � PIPE DROP 31. PROVIDE ROCKWELL, NORDSTROM, CRANE, WALWORTH, OR APPROVED EQUAL PLUG TYPE STOP
<br /> DWG DRAWING 3. PRIOR TO BEGINNING CONSTRUCTION, CONTRACTOR SHALL CONFIRM WITH IN-N-OUT BURGER
<br /> UNION TOP CONNECTION TO BRANCH (I-N-O-B) THAT NO EQUIPMENT SUBSTITUTIONS WILL BE MADE TO PROTOTYPEFAILURE TO DO COCKS IN THE GAS LINES, IN EACH BRANCH LINE AND RISER, SERVING TWO OR MORE OUTLETS.
<br /> .
<br /> DWV DRAINAGE WASTE AND VENT PROVIDE STOP COCK AT EACH OUTLET WITH A UNION BETWEEN IT AND THE EQUIPMENT SERVED.
<br /> EXIST EXISTING STRAINER .. BOTTOM CONNECTION TO BRANCH SO WILL MAKE IT THE CONTRACTOR'S RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATIONS OR (THE FIRING VALVE CONTROL SHALL NOT BE CONSTRUED AS SUITABLE FOR SHUT-OFF.)
<br /> `i' MODIFICATIONS. PROVIDE MASTER SHUT-OFF VALVE AT THE METER, AT MAIN BRANCHES, AND AS SHOWN ON
<br /> FCO FLOOR CLEANOUT F FIRE MAIN 4. CAREFULLY INSPECT ALL EQUIPMENT RECEIVED AND VERIFY THAT IT IS COMPATIBLE WITH THE PLANS.
<br /> FDC FIRE DEPARTMENT CONNECTION 7 CAP OR PLUG FW FILTERED WATER MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS PRIOR TO INSTALLING EQUIPMENT. CONTACT WASTE AND VENT REVISION RECORD
<br /> FDVC FIRE DEPARTMENT VALVE CABINET ARCHITECT OR ENGINEER FOR DIRECTION IF ANY DISCREPANCY ARISES.
<br /> FH FIRE HYDRANT Q - COLD WATER
<br /> AQUASTAT 5. REFER TO ARCHITECTURAL PLANS AND KITCHEN PLANS FOR FINAL LOCATIONS AND ELEVATIONS OF 32. SANITARY AND GREASE WASTE PIPING AND VENT PIPING SHALL BE SCHEDULE 40 PVC PIPE
<br /> FIN FINISHED - - HOT WATER (1407) ROUGH-IN TO EQUIPMENT. MAKE ALL CONNECTIONS. REFER ALSO TO MECHANICAL AND CONFORMING TO ASTM D2665 WHERE PERMITTED BY THE A.H.J.
<br /> FL FLOOR 4 n WHA WATER HAMMER ARRESTOR ELECTRICAL PLANS FOR PLUMBING CONNECTIONS. CONTRACTOR SHALL FIELD VERIFY AND
<br /> FPS FEET PER SECOND - - - HOT WATER CIRC (1407) CONTACT ARCHITECT FOR DIRECTION IF ANY SIGNIFICANT DISCREPANCY IS FOUND. 33. ALL EXPOSED DRAIN PIPING FOR HANDSINKS AND RESTROOM LAVATORIES SHALL BE CHROME
<br /> PLATED.
<br /> FT FEET PG PRESSURE GAUGE WITH COCK SW SANITARY WASTE WATER SUPPLY
<br /> FU FIXTURE UNITS n T 34. CONDENSATE DRAINS SHALL BE COPPER AND RUN TO HUB DRAIN, FLOOR SINK, OR MOP SINK
<br /> FW FILTERED WATER 4 THERMOMETER GW GREASE WASTE 6. ALL HOT, COLD, AND FILTERED WATER PIPING SHALL CONFORM TO NSF 61. IT SHALL BE WITH INSULATED PIPE, SIZED AS SHOWN (U.N.O.). MAINTAIN A MINIMUM OF 6" ABOVE FLOOR
<br /> G GAS I SECURED AND PROPERLY SUPPORTED ABOVE CEILINGS AND WITHIN WALLS, UNEXPOSED TO VIEW, AND %" FROM WALLS. SLOPE AT 10% IF FEASIBLE.
<br /> ----------- VENT WHEREVER POSSIBLE. SURFACE MOUNTED PIPING IS NOT ACCEPTABLE, UNLESS APPROVED IN
<br /> GCO GROUND CLEANOUT (AT GRADE) � I CO CLEANOUT PLUG WRITING BY ARCHITECT. 35. CONTRACTOR SHALL PROVIDE HARD COPPER INDIRECT WASTE FROM KITCHEN EQUIPMENT.
<br /> GPH GALLONS PER HOUR RD ROOF DRAIN PIPING REFER TO KITCHEN PLANS. PROVIDE PROPER BRACING FROM EQUIPMENT OR BACK WALL TO
<br /> GPM GALLONS PER MINUTE FCO FLOOR CLEANOUT 7. PROVIDE VIBRATION ISOLATION. PROVIDE WATER HAMMER ARRESTORS CONFORMING TO ASSE 1010 PREVENT MOVEMENT OR DAMAGE. TERMINATE WITH CODE-APPROVED AIR GAP.
<br /> GV GATE VALVE OD OVERFLOW DRAIN PIPING AND SIZED/LOCATED AS SHOWN OR IN ACCORDANCE WITH PDI-WH2O1.
<br /> 36. ALL HORIZONTAL SANITARY AND GREASE WASTE PIPING SHALL BE RUN AT A MINIMUM SLOPE OF
<br /> HD HUB DRAIN -4 HB HOSE BIBB 8. ALL HOT AND COLD WATER PIPING ABOVE FLOOR AND EXPOSED DRAIN PIPING SHALL BE TYPE 2% (1/4" PER FT.), U.N.O.
<br /> HW HOT WATER (SUPPLY) D INDIRECT DRAIN LINE "L" HARD TEMPER COPPER PIPING CONFORMING TO ASTM B88 AND NSF 61 WITH WROUGHT
<br /> COPPER SOLDER JOINT FITTINGS AND LEAD-FREE (<0.25%) SOLDER (U.N.O.). HIDDEN OR 37. CLEANOUTS SHALL BE PROVIDED IN SANITARY AND GREASE WASTE AT CHANGE OF DIRECTION
<br /> HWR HOT WATER RETURN (RECIRCULATION) FIRE RISER G NATURAL GAS (7" WC, UNO) PROTECTED DRAIN PIPING MAY BE TYPE "DWV" CONFORMING TO ASTM B306. EXCEEDING 45' AND IN INTERIOR INTERVALS NOT EXCEEDING 50 FT. CLEANOUTS SHALL BE
<br /> 1.E. INVERT ELEVATION SAME SIZE AS PIPE AND MADE OF BRASS CAULKED INTO LINES WITH ADJUSTABLE ACCESS
<br /> FIRE ALARM BELL E 9. UNDERFLOOR WATER PIPING SHALL BE TYPE "K" SOFT-DRAWN COPPER TUBING CONFORMING TO PLATES IN FINISHED AREAS. EXTERIOR CLEANOUTS SHALL BE ENCASED IN CONCRETE AT
<br /> MBH THOUSANDS BTU/HR ( ) EXISTING PIPE ASTM B88 WITH WROUGHT COPPER SOLDER JOINT FITTINGS AND SILVER SOLDERED JOINTS. GRADE. DO NOT INSTALL CLEANOUTS IN DINING AREA.
<br /> / I � PROFESSIONAL SEAL
<br /> MFG MANUFACTURER COPPER WATER LINES TO BE PROTECTED AND MUST BE INSULATED UNDERGROUND.
<br /> N.C. NORMALLY CLOSED 38. PROVIDE CLEANOUTS IN INDIRECT DRAINS AT CHANGE OF DIRECTION EXCEEDING 45'. INSTALL IN
<br /> NFPA NATIONAL FIRE PROTECTION ASSOCIATION 10. FILTERED WATER PIPING TO ICE MACHINES, BEVERAGE DISPENSERS, AND COFFEE/TEA BREWERS ACCORDANCE WITH 2016 CPC. FOR EXAMPLE, PROVIDE TRAP WHERE DRAIN EXCEEDS 2 FT. IN
<br /> SHALL CONFORM TO ASTM F876 & F877 AND I-N-O-B'S AND BEVERAGE VENDOR'S HORIZONTAL OR 4 FT. IN OVERALL DEVELOPED LENGTH. Q
<br /> N.O. NORMALLY OPEN REQUIREMENTS.
<br /> PIPING MATERIALS 39. PROVIDE GREASE INTERCEPTOR IN COMPLIANCE WITH A.H.J. CONFORM TO PDI G101 AND ASME
<br /> NIC NOT IN CONTRACT
<br /> 11. PROVIDE SHUT-OFF VALVES AND MAKE FINAL CONNECTION PER MANUFACTURER'S A112.14.3 & A112.14.4. r�r
<br /> OCD OVERFLOW CONDENSATE DRAIN RECOMMENDATIONS TO EACH FIXTURE AND PIECE OF KITCHEN EQUIPMENT. PROVIDE CHROME ke9a ►�►
<br /> OFCI OWNER FURNISHED CONTRACTOR INSTALLED 1. SANITARY WASTE AND VENT SERVICE WEIGHT NO-HUB CAST IRON WITH 4 OR 6 PLATED VALVES WHERE EXPOSED. REFER TO KITCHEN PLANS AND ARCHITECTURAL PLANS FOR MISCELLANEOUS
<br /> ADDITIONAL REQUIREMENTS.
<br /> POC POINT OF CONNECTION PIPING BELOW GRADE: BAND STAINLESS STEEL COUPLINGS. PIPE WRAP ALL 40. CONTRACTOR SHALL PROVIDE PIPE SLEEVES FOR ALL PIPES PASSING THROUGH FOUNDATION o
<br /> I POUNDS
<br /> EER SQUARE
<br /> INC RAP (PETES PLUG) LOCAL CODE ALLOWS USE).GRABS OR SDR GASKETED (IF 12. NOTE THAT SOME WATER ROUGH-INS ARE COMMON TO SEVERAL PIECES OF KITCHEN EQUIPMENT. WALLS. USE SLEEVE ONE SIZE LARGER THAN PIPE AND SEAL AROUND SLEEVE AND PIPE.
<br /> PTPy �D
<br /> MAKE FINAL CONNECTION TO EACH. REFER TO STRUCTURAL PLANS FOR ADDITIONAL INFORMATION.
<br /> RPZ REDUCED PRESSURE ZONE BACKFLOW PREVENTER 13. ALL HANDSINKS IN KITCHENS AND LAVATORIES IN RESTROOMS SHALL BE PROVIDED WITH A 41. ALL PLUMBING LINES THROUGH CONCRETE TO BE PROTECTED FROM BREAKAGE BY BEING
<br /> RPM REVOLUTIONS PER MINUTE 2. SANITARY WASTE AND VENT SERVICE WEIGHT CAST IRON WITH STAINLESS STEEL PIPING ABOVE GRADE: COUPLINGS OR ABS (IF LOCAL CODE ALLOWS USE). THERMOSTATIC MIXING VALVE CONFORMING TO ASSE 1016, ASSE 1062, OR ASSE 1070 (AS WRAPPED WITH 'DOW STYROFOAM SILL SEAL" POLYETHYLENE GASKETING STRIP. PIPE WRAP TO SOV SHUT-OFF VALVE REQUIRED BY APPLICATION) SET TO SUPPLY TEMPERED WATER AT 110F, U.N.O. BE SECURED TO PIPING AND COVER ENTIRE LENGTH OF PIPING THROUGH FOUNDATION TO 2"
<br /> TP TRAP PRIMER 3. WATER PIPING BELOW GROUND: TYPE 'K' COPPER WITH LEAD FREE SOLDER JOINTS. ABOVE FINISHED FLOOR AND BELOW VAPOR BARRIER.
<br /> TS TAMPER SWITCH 14. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTER (RPZ) CONFORMING TO ASSE 1013 E MAIN 42. GENERALLY ROUTE PIPING AS HIGH AS POSSIBLE TO STRUCTURE. START SLOPED PIPING SUCH
<br /> 4. WATER PIPING ABOVE GROUND: TYPE 'L' COPPER WITH LEAD FREE SOLDER JOINTS. WATER SERVICE. (TESTING SHALL BE PERFORMED BY BACKFLOW PREVENTION ASSEMBLY TESTER AS ROOF AND CONDENSATE DRAINS AS HIGH AS POSSIBLE AND COORDINATE ALL WORK WITH
<br /> TWCO TWO-WAY CLEANOUT REGISTERED/LICENSED BY CITY.) OTHER TRADES.
<br /> TYP TYPICAL 5. CONDENSATE DRAIN PIPING: TYPE 'L' COPPER WITH LEAD FREE SOLDER JOINTS.
<br /> 15. PROVIDE RPZ AT SUPPLY OF WATER FILTERS, COFFEE & TEA BREWERS, CARBONATED DRINK 43. ROUTE ALL DRAIN, WATER, AND GAS LINES TIGHT AND SECURE TO THE UNDERSIDE OF t M
<br /> Chart A-1 UPC UN UNION DISPENSERS CONFORMING TO ASSE 1022. STAINLESS STEEL RPZ SHALL BE USED ON EQUIPMENT. engineering COnSUItontS
<br /> friction Looses for disk-type water Meter UTR UP THROUGH ROOF 6. INSULATION OF COLD & HOT GLASS FIBER PIPE INSULATION WITH FACTORY APPLIED CARBONATED AND OTHER CORROSIVE LIQUIDS. DO NOT USE COPPER PIPE DOWNSTREAM OF SS
<br /> 2 6 rtmassociates.com 972.387.3500
<br /> VB VACUUM BREAKER WATER SUPPLY, HORIZONTAL WHITE JACKET, J-M MICRO-LOK 750AP: 1/2" FOR CW, RPZ FOR CARBONATED LIQUIDS. PROVIDE RPZ (OR ATMOSPHERIC VACUUM BREAKER ON 44. PROVIDE HEAT TRACE ON PIPING ABOVE GRADE IN TRASH ENCLOSURE, ON EXPOSED HOT AND 14901 Quorum Dr. #565 Dallas, . 75254
<br /> 6 hm IV V VENT RAIN LEADERS, AND CONDENSATE DRAINS, AND RAIN LEADERS, 1 INCH THICK HOSEBIBB IF ACCEPTABLE TO A.H.J.) ON WATER INJECTED SOAP DISPENSERS. PROVIDE RPZ AT COLD WATER PIPING IN TOWER, ON EXPOSED TRAPS OF DRAIN PIPING, AND ON P&T RELIEF 3
<br /> 10 VTR VENT THROUGH ROOF CONDENSATE DRAIN PIPING: FOR HW UP 2"0AND 1.5 INCH FOR 2.5"0 AND LARGER. PRESSURE WASHER IN TOWER. ROUTE DRAIN FROM RPZ'S TO NEAREST FLOOR SINK OR DRAIN FROM WATER HEATERS IF SHOWN/SPECIFIED OR, IF NOT SHOWN, IN CLIMATES WITH
<br /> �8 APPROVED LOCATION. WINTER ASHRAE 0.4% DESIGN TEMPERATURES OF LESS THAN 28' F. 18.GHAA.033
<br /> 6 W WASTE
<br /> 5 WCO WALL CLEANOUT 7. GAS PIPING ABOVE GRADE: SCHEDULE 40 BLACK STEEL PIPE WITH BLACK 16. PROVIDE PRESSURE REDUCING VALVES CONFORMING TO ASSE 1003 FOR ALL HOT AND COLD 45. HEAT TRACE SHALL BE EQUAL TO RAYCHEM / TYCO #5XL-1-CR, 5 W/FT AT 120V AND 40F PROTOTYPE VERSION
<br /> 4 MALLEABLE SCREW FITTINGS (LISTED FOR "CONCEALED WATER PIPES SERVING EQUIPMENT IF PRESSURE EXCEEDS 80 P.S.I. DOWNSTREAM ON RPZ ON START-UP. PROVIDE INSULATION AS SPECIFIED ELSEWHERE, OR A MINIMUM OF URBAN DESIGN
<br /> 2.67LOCATIONS"). GALVANIZED STEEL PIPE WHERE MAIN. 1/2" (FIBERGLASS WITH ASJ) OVER HEAT TRACE AND DRAIN LINE.
<br /> 2 EXPOSED BEHIND FRYERS IN KITCHEN IF PERMITTED 17. CONTRACTOR SHALL TEST WATER PRESSURE DOWNSTREAM OF WATER METER AND BACKFLOW 46. REFER TO STRUCTURAL PLANS AND KITCHEN PLANS FOR INSTALLATION OF FLOOR SINKS AND
<br /> �" ry BY A.H.J. PREVENTER (WITH FLOW - 50 GPM). IF LESS THAN 60 P.S.I., CONTACT ARCHITECT / ENGINEER. FLOOR DRAINS, INCLUDING SLOPING OF FLOOR. PROJECT NAME
<br /> 4 5 6 7 8910 8. RAIN CONDUCTORS / LEADERS SERVICE WEIGHT CAST IRON WITH STAINLESS STEEL 47. AT ACCESSIBLE WATER CLOSETS, CONTRACTOR SHALL INSTALL FLUSH HANDLE ON THE WIDE SIDE N N 0 UT
<br /> Flow-Gallons5p Minute a m - COUPLINGS. PROVIDE 1 2" INSULATION ON HORIZONTAL 18. CONTRACTOR SHALL DISINFECT ALL WATER SUPPLY PIPING AND SYSTEMS IN ACCORDANCE WITH OF WATER CLOSET. REFER ALSO TO ARCHITECTURAL DETAILS FOR LOCATIONS AND HEIGHTS OF
<br /> / AWWA C651 OR LOCAL CODE, WHICHEVER IS MORE STRINGENT. OF
<br /> OTHER FIXTURES.
<br /> PIPES. BURGER
<br /> Chart A-3 UPC 9. ALL DUCTILE-IRON UNDERGROUND WASTE PIPE SHALL BE WRAPPED WITH 20 MIL PVC INSULATION 48. CONTRACTOR SHALL SNAKE ALL DRAIN LINES AND SANITARY SEWER LINES PRIOR TO APPLYING
<br /> Enlarged Scale Demand Load PIPE TAPE AND PRIME OR INSTALL IN 8 MIL POLYETHYLENE ENCASEMENT INFOR FINAL PAYMENT.
<br /> 19. PIPE INSULATION SHALL BE EQUAL TO OWENS CORNING FIBERGLAS "ASJ/SSL" OR JOHNS
<br /> 100 ACCORDANCE WITH ANSI/AWWA C105/A21.5-82. MANVILLE "MICRO-LOK" HAVING ALL SERVICE JACKET. PROVIDE PLASTIC JACKET OUTDOORS AND 49. PROVIDE VALVES AND UNIONS OF SAME SIZE AND PRESSURE RATING AS SYSTEM AT PROPER
<br /> WHERE EXPOSED TO PHYSICAL DAMAGE. ARMAFLEX OR EQUAL OF REQUIRED R-VALUE MAY BE POINTS TO ALLOW REMOVAL OF EQUIPMENT, PIPE, ETC. WITHOUT DAMAGE TO OTHER PARTS OR LAT H R 0 P
<br /> 80 10. ABS OR PVC (SCHEDULE 40) PIPING MAY BE USED FOR SANITARY AND GREASE WASTE, PROVIDED
<br /> WHERE PERMITTED BY A.H.J. INSTALL WITH ADHESIVE AND FOR USE AS RECOMMENDED SYSTEMS.
<br /> 60 VENT, AND ROOF DRAINAGE WITH PRIOR APPROVAL FROM LOCAL BUILDING OFFICIAL (A.H.J.). MANUFACTURER.BY
<br /> 50. PROVIDE DIELECTRIC UNIONS TO SEPARATE DISSIMILAR MATERIAL PIPES AND WHERE SHOWN FOR CALIFORNIA
<br /> I56 49 20 FIBERGLASS.ALL ALLLHHOT'ATER WATERI PING PINGNSHA LCONDENSATEINSULTED WITH AIL FIIBERGLASSE(CONIDUCTVITY EQUIPMENT REMOVAL.
<br /> 20 LESS THAN 0.27 BTU/(IN*HR*FT2*F)). COMPLY WITH APPLICABLE ENERGY CODE. 51. ALL WATER PIPING AND SEWERS SHALL BE PROPERLY TESTED TO THE SATISFACTION OF THE
<br /> PLUMBING DRAWING LIST A.H.J. AND ARCHITECT. GIVE ARCHITECT 72 HOURS NOTICE PRIOR TO CONDUCTING TEST. 16514 GOLDEN VALLEY PKWY
<br /> o zo ao 6 8° 100 ,z0 14° 16° 180 zoo zz° X40 21. INTERIOR HORIZONTAL ROOF DRAINS AND LEADERS SHALL BE INSULATED WITH 1/2° FIBERGLASS. 52. TRENCHES SHALL BE BACK-FILLED WITH CLEAN SOIL BY TAMPING OR PUDDLING IN
<br /> 64 Fixture Unite P1.0 PLUMBING LEAD SHEET - GENERAL NOTES GAS PIPING 6" INCREMENTS. NO PIPE SHALL BE LESS THAN 12" BELOW FINISHED GRADE. LATHROP, CA 95330
<br /> P1.1 PLUMBING SCHEDULES & DETAILS 22. CONTRACTOR SHALL CONTACT GAS COMPANY TO COORDINATE INSTALLATION OF NEW GAS METER 53. CONTRACTOR SHALL DEBUR AND FILE ALL SHARP EDGES OF INSTALLED PIPING AND EQUIPMENT
<br /> Chart A-4 UPC WHICH MAY COME IN CONTACT WITH CUSTOMERS OR EMPLOYEES. FOR EXAMPLE, FILE DOWN
<br /> a0000 WINNER D
<br /> TOTAL PIPING LENGTH OR TOTAL LOADS INCREASE OR IF METER DISCHARGE PRESSURE IS LOW.ER CALCULA'nONS (2016 CPC) APPENDIX 'A' P2.0 PLUMBING SITE PLAN AND APPROPRIATE PRESSURE REGULATOR. CONTACT ARCHITECT ENGINEER FOR DIRECTION IF AND SMOOTH EDGES OF INDIRECT DRAIN OPENINGS ABOVE FLOOR SINKS SO THAT EMPLOYEES
<br /> P3.0 WATER AND GAS PLUMBING PLAN CAN SAFELY CLEAN.
<br /> PROVIDE APPROVED GAS PRESSURE REGULATORS. ALL WORK SHALL COMPLY WITH NFPA 54.
<br /> 6000
<br /> 5000 DOMESTIC WATER SERVICE = WITH 2" SUPPLY P4.0 WASTE AND VENT PLUMBING PLAN
<br /> 4000 23. GAS PIPING OUTSIDE ABOVE GRADE, INSIDE ABOVE CEILING, AND ABOVE ROOF SHALL BE
<br /> 3000 P5.0 PLUMBING ROOF PLAN AMERICAN MANUFACTURED, NEW SCHEDULE 40 STANDARD WEIGHT BLACK STEEL PIPE. PIPING
<br /> z000 64 WSFU = 56 GPM - ON FLUSH VALVE SYSTEMS (CHART A-3) 2-1/2" AND LARGER SHALL BE WELDED AND PIPING 2" AND SMALLER SHALL BE THREADED AND
<br /> s P6.0 GAS RISER DIAGRAM HAVE 150 LB., BLACK MALLEABLE IRON SCREW FITTINGS CONFORMING TO ASTM A53. NmNmOUT
<br /> 55.4 GPM = 2.67 PSI LOSS - FOR DISK TYPE WATER METER (CHART A-1)
<br /> 1000 PTO WASTE AND VENT RISER DIAGRAM
<br /> Soo 24. EXPOSED GAS PIPING EXPOSED BEHIND FRYERS SHALL BE GALVANIZED STEEL CONFORMING TO \BVRGERo
<br /> 500 m AVAILABLE PRESSURE ASSUMED - 50 PSI P8.0 WATER RISER DIAGRAM ASTM A53. VERIFY IF PERMITTED BY A.H.J. PRIOR TO ORDERING.
<br /> 400 r1
<br /> s 300 E PRESS. LOSS ACROSS METER LOSS - 2.67 PSI GOD BLESS AMERICA
<br /> 200
<br /> CP"Iti STATIC PRESS. LOST (ELEV.) (10'-0" X 0.43) LOSS - 4.3 PSI
<br /> 100 c
<br /> so S. GOVERNING FIXTURE - WATER CLOSET (TOTO) LOSS - 25 PSI
<br /> so 56
<br /> 40 BACKFLOW PREVENTER - (2" RPZ) LOSS - 10 PSI
<br /> 30
<br /> a 20 TOTAL PRESSURE AVAILABLE 8.03 PSI PROJECT NUMBER
<br /> 180641.001
<br /> ao DISTANCE FROM WM TO LAST FIXTURE 176'
<br /> 5 SHEET TITLE
<br /> AA 4 TOTAL DEVELOPED LENGTH OF SYSTEM (X 1.25) 220'
<br /> 3
<br /> z ALLOW. PRESS. 8.03 X 100' 3.65 PSI PLUMBING
<br /> E NN�_ IN I LOSS/100 FT. 220' LEAD SHEET
<br /> 0.1 0.2 0.3 0.4 0.6 0.8 1 2 3 4 5 678910 20 30 0 50 60 80100
<br /> 2.89 AVERAGE PRESS. DROP AVAILABLE FOR FRICTION 3.65 PSI
<br /> Friction Lose - Lbs. per Square-inch Head per 100-Foot Length 2.89 PSI
<br /> i FRICTION LOSS-LBS. PER SQ. IN. HEAD PER 100-FOOT LENGTH
<br /> SMOOTH PIPE - FIGURE E103.3(2) VELOCITY = 5.9 FPS
<br /> z �
<br /> - N
<br /> Q
<br /> U
<br /> cr; SHEET NUMBER
<br /> < V
<br /> M
<br /> mP1
<br /> ■
<br /> W
<br /> f- ♦-
<br /> Z Z
<br /> � �
<br />
|