My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GOLDEN VALLEY
>
16514
>
1600 - Food Program
>
PR0544910
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2023 11:15:33 AM
Creation date
8/12/2020 8:15:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0544910
PE
1625
FACILITY_ID
FA0025530
FACILITY_NAME
IN-N-OUT BURGER #346
STREET_NUMBER
16514
STREET_NAME
GOLDEN VALLEY
STREET_TYPE
PKWY
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16514 GOLDEN VALLEY PKWY
P_LOCATION
07
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
750
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> To reduce the risk associated with property damage due to water leakage: <br /> • Read and follow Use Instructions before installation and use of this system. <br /> • Before starting installation, shut off main water supply and drain pipes. <br /> • Installation and Use MUST comply with all state and local plumbing codes. <br /> • Protect from freezing. Remove cartridge when temperatures are expected to drop below 40° F (4.4° C); <br /> • Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 100°F (37.8°C). <br /> • Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa) you must <br /> install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure. <br /> • Do not install where water hammer conditions may occur. If water hammer conditions exist, you must install a water hammer <br /> arrester. Contact a plumbing professional if you are uncertain how to check for this condition. <br /> • Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing. <br /> • Do not install unit if collet is missing. Contact your Sales Representative if collets are missing from any fittings. <br /> • On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic. <br /> • Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if overtightening occurs. <br /> • Do not install in direct sunlight or outdoors without protection from precipitation. <br /> • Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket. <br /> • Mount filter in such a position as to prevent it from being struck by other items used in the area of installation. <br /> • Ensure that the location and fasteners will support the weight of the system when installed. <br /> • Ensure all tubing and fittings are secure and free of leaks. <br /> • Tank Pressure should be checked yearly. <br /> • The filter cartridge MUST be replaced every 12 months or at the rated capacity or if a noticeable reduction in flow rate occurs. <br />To reduce the risk associated with choking: <br /> • Do not allow children under 3 years of age to have access to small parts during the installation of this product. <br />To reduce the risk associated with the ingestion of contaminants: <br /> • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. <br />To reduce the risk associated with hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area <br />of installation: <br /> • Do not install near electric wiring or piping which may be in path of a drilling tool when selecting the position to mount the filter bracket. <br />To reduce the risk of physical injury: <br /> • Depressurize system as shown in manual prior to cartridge removal. <br />To reduce the risk associated with back strain: <br /> • Follow safe lifting procedures. <br />WarNING <br />CaUTION <br />EXPLANATION OF SIGNAL WORD CONSEQUENCES <br />WARNING Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage. <br /> CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or property <br />damage. <br /> CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in property damage. <br /> • Failure to follow instructions may void warranty. <br /> • Allow a minimum of 1.5” (3.81 cm) clear space under filter to facilitate cartridge change. <br /> • Install with the inlet and outlet ports as labeled. Make sure not to reverse connections. <br /> • Some local codes may require the use of a licensed plumber or certified installer when disrupting a potable water line. <br /> <br />IMPOrTaNT NOTES <br />2 <br />SAFETY INFORMATION <br />Read, understand, and follow all safety information contained in these instructions prior to installation and use of the 3M™ Water Filtration <br />Products Reverse Osmosis Water Treatment System. Retain these instructions for future reference. <br />Intended use: <br />The FlashGARD FSTMO75 Water Treatment System is intended for use in filtering potable water for food service coffee, espresso and steamer <br />equipment and has not been evaluated for other uses. The system is installed indoors near where filtered drinking water is desired, and must be <br />installed as specified in the installation instructions by qualified professional installer.
The URL can be used to link to this page
Your browser does not support the video tag.