Laserfiche WebLink
THIS PROJECT INVOLVES THE REMODEL OF AN EXISTING QUICK ADDRESS: 3507 W HAMMER LANE,STOCKTON,CA 95219 TITLE / ADA / ENERGY / SURVEY <br /> SERVE DRIVE-THRU (TACO BELL) RESTAURANT. THE BUILDING BUILDING CODES: 2016 CALIFORNIA BUILDING CODE T1.0 TITLE SHEET <br /> 2016 CALIFORNIA PLUMBING CODE <br /> EXTERIOR WILL RECEIVE NEW PAINT COLORS AND NEW MOSIAC TILE 2016 CALIFORNIA MECHANICAL CODE 662 GAL GREEN BUILDING GE)BE 61 1EE:F6 <br /> WAINSCOT AND NEW SIGNAGE (UNDER SEPARATE PERMIT). 2016 CALIFORNIA ELECTRICAL CODE <br /> 2016 CALIFORNIA EXISTING BUILDING CODEAr)A MICADI ED ACCESSIBILITY EXTERIOR.DETAILS <br /> 2016 INTERNATIONAL EXISTING BUILDING CODE AnnAnn 3 nicAR1 EDA-AGGESeIR1LITY INTERIOR PETA168 <br /> REMODEL OF INTERIOR OF BUILDING INVOLVES NEW SEATING AND 2016 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS <br /> T24.1 T-24.2- ENERGY crrr"ci ri iravc"rrTiv448 <br /> DECOR AND FINISHES TO DINING AREA, RESTROOMS REMODELED TO BUILDING AREA: 2,350±SQUARE FEET(EXTERIOR FACE OF STUD OF HABITABLE SPACE) <br /> F COMPLY WITH ADA AND NEW LED LIGHTING TO REPLACE EXISTING. <br /> U Z <br /> Cn <br /> U05 CONSTRUCTION TYPE: MAIN BUILDING:VB NOWSPRINKLERED CIVIL <br /> NOTE- NO ADDITIONAL AREA TO BUILDING FOOT PRINT <br /> w= OCCUPANCY: "A2" CONSTRUCTION V-B-NON-SPRINKLERED X29- TE roA13 r,r PLAN� <br /> o Z SEATING: EXISTING 60 SEATS PROPOSED 58 SEATS <br /> 010 <br /> U <br /> O <br /> NO ADDITION TO EXISTING BUILDING OR FOOTPRINT. <br /> z of <br /> co <br /> STORIES: SINGLE <br /> = NO CHANGE IN NUMBER OF PARKING SPACES. MAXIMUM HGT.: 18' 9" DEMO <br /> LU <br /> D1.0 DEMOLITION FLOOR PLAN <br /> LU w NO TREES REMOVED. EXISITNG TREES AND LANDSCAPE TO D2.0 DEMOLITION R.C.P. <br /> ui <br /> w VM1 arckitecture <br /> 0,0 REMAIN. BUILDING AREA 2,350 S.F.+/- D3.0 DEMO ELEVATIONS Design Planning Interiors <br /> LU Of <br /> 0 637 5th Avenue San Rafael, CA 94901 <br /> o m SITE WORK-SLURRY SEAL PARKING LOT AND RESTRIPE. 415-451-2500 415-451-2595 fax <br /> 0 a ARCHITECTURAL www.vmarch.com <br /> NO CHANGE IN NUMBER OF PARKING SPACES. <br /> oa AO.0 SITE PLAN <br /> 0 4G'`� NO ADDITIONAL BUILDING AREA PROPOSED. E DETAILS VMI JOB NUMBER <br /> w LU A10.0 FLOOR PLAN <br /> o A1.1 DOOR&WINDOW ELEVATIONS&SCHEDULE 1861 <br /> a-0 SCOPE OF WORK H PROJECT SUMMARY D A1.2 OCCUPANTLOAD <br /> [E2) <br /> A2.0 SEATING PLAN <br /> IL <br /> o A. ALL WORK SHALL CONFORM TO THE 2013 EDITION OF THE CALIFORNIA BUILDING CODE,AND ALL OTHER APPLICABLE A4.0 EXTERIOR ELEVATIONS <br /> 0>_F__ jC( ® CODES,STANDARDS,AND REGULATIONS OF THE CITY OF STOCKTON AND SAN JOAQUIN COUNTY.DO A4.1 EXTERIOR ELEVATIONS <br /> m A6.0 CONSTRUCTION DETAILS <br /> Q U) B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. f <br /> o m A7.0 FLOOR FINISH PLANti <br /> IL <br /> o C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION(A.I.A. LATEST EDITION)ARE A PART OF THESE A7.1 REFLECTED CEILING PLAN <br /> A7.2 FINISH SCHEDULE <br /> oU CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. A8.0 INTERIOR ELEVATIONS DINING ROOM No. C 1 7 928 <br /> E <br /> REMO EL D. DUE TO THE NATURE OF THE WORK,ALL DIMENSIONS SHOWN SHALL BE CONSIDERED APPROXIMATE.CONTRACTOR SHALL A8.1 INTERIOR ELEVATIONS-TOILET ROOMS, ENLARGED TOILET ROOMS PLAN P.. <br /> D'a FIELD VERIFY ALL DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION.SHOP DRAWINGS SHALL BE SUBMITTED TO THE t1T�, �%\ <br /> 11 <br /> }a ARCHITECT FOR REVIEW PRIOR TO FABRICATION OF ANY ITEM. FAILURE TO ADHERE TO THIS PROCEDURE SHALL PLACE MECHANICAL <br /> 0T C <br /> a o FULL RESPONSIBILITY FOR ANY ERRORS DIRECTLY UPON THE CONTRACTOR. <br /> N M1.0 MECHANICAL PLAN <br /> 0 o E. INFORMATION CONCERNING EXISTING BUILDING STRUCTURE,SIZE,LOCATION OF EQUIPMENT, FINISHES, ETC. WAS <br /> o OBTAINED FROM VARIOUS PLANS FOR CONSTRUCTION OF THE EXISTING BUILDING. EVERY EFFORT HAS BEEN MADE TO <br /> o U5 ACCURATELY DEPICT EXISTING CONDITIONS,HOWEVER ALL WORK MUST BE VERIFIED IN THE FIELD PRIOR TO PLUMBING <br /> CONSTRUCTION.ANY CONFLICT BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED P1.0 PLUMBING PLAN <br /> w IMMEDIATELY TO THE ARCHITECT FOR VERIFICATION AND/OR CORRECTION. <br /> c� <br /> yj <br /> °'w F. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE ELECTRICAL <br /> = 3507 W. HAMMER LANE <br /> m DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK. <br /> ' E1.0 LIGHTING PLAN AND SCHEDULE <br /> = G. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE ARCHITECT, IN WRITING, PRIOR TO INSTALLATION. <br /> U) <br /> H. THE GENERAL CONTRACTOR SHALL USE EXTREME CAUTION IN DEMOLITION OF EXISTING CONSTRUCTION.ANY ITEM SPECIAL INSPECTIONS E <br /> �= STOCKTON , : <br /> Z o NATURE SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO DEMOLITION. BY FAILURE TO DO SO, THE CONTRACTOR /. .E�r San Joaquin County <br /> a ASSUMES FULL RESPONSIBILITY FOR THE CONSEQUENCES OF SUCH ACTION. CLIENT / OWNER ARCHITECT :\ Environmental Health Department <br /> Q z PRB MANAGEMENT,LLC VMI ARCHITECTURE 1 1868 E. Hazelton Ave. <br /> z o STORE # 2832 4709 MANGELS BLVD., 637 FIFTH AVENUE . <br /> C Z 1. G.C. IS RESPONSIBLE FOR SUBMITTAL, PAYING FEES AND OBTAINING ALL PERMITS ASSOCIATED WITH THE PROJECT Stockton, CA 95205 <br /> w FAIRFIELD,CA 94534 SAN RAFAEL,CA 94901 <br /> o s EXCEPT GENERAL BUILDING PERMIT. THIS INCLUDES,BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE 209 468-3420 <br /> CONTACT:DAMIEN HANNIGAN,PROJECT MANAGER <br /> CONTACT:DAVE FULWILER \ 3 oR`'�� <br /> SPRINKLER, HOOD ANSUL,OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT,ETC. OWNER WILL PAY FORUj <br /> o "CONNECTION FEES"ASSOCIATED WITH UTILITY PERMITS. G.C. REQUIRED TO PAY FOR TEMPORARY FACILITIES FEES AS PHONE:(707)864 2919/EMAIL: dfulwiler@directcon.net PHONE:(415)451-2500/EMAIL:DHANNIGAN@VMARCH.COM <br /> U) X DETAIL REQUIRED TO COMPLETE THE WORK INATIMELY MANNER. GENERAL CONTRACTOR APPROVED WITH CONDITIONS <br /> AX.X X DETAIL NUMBER ROOM ROOM NAME <br /> ZAX.X SHEET NUMBER J. G.C.SHALL PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY-PERMITTED DRAWING SET AT TIME OF TBD For conditions, please see approval letter dated: 12-31-18 <br /> } CONSTRUCTION. <br /> G LL SECTION CALLOUT N P-X FINISH CALLOUT K. THE GENERAL CONTRACTOR SHALL REMOVE EXISTING TRIM AND SURFACES AS REQUIRED TO PROVIDE A PLUMB AND TRUE Approved by: y6d&� P�ra'�' Date: Dec 31 , 2018 <br /> o X X SECTION NUMBER RECORD DATES <br /> o LL AX.X AX.X- SHEET NUMBER SURFACE SUITABLE FOR THE APPLICATION OF NEW WALL FINISHES. <br /> DD SUBMITTAL <br /> IL Q OX KEY NOTE L. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT PROJECT DIRECTORY F BLDG.SUBMITTAL 12/03/2018 <br /> U)�_ EXT. ELEVATION CALLOUT <br /> LU U) X CLEARBID SET - <br /> AX.X X ELEVATION NUMBER . <br /> AX.X- SHEET NUMBER OX WINDOW NUMBER/ARTWORK NUMBER BUILDING DEPARTMENT PLANNING DEPARTMENT CONTRACTSET <br /> Z o M. THE CONTRACTOR SHALL SHORE AND/OR UNDERPIN EXISTING WORK AS REQUIRED TO SAFELY INSTALL NEW WORK.THIS City of Stockton,Community Development Department City of Stockton, Planning Department <br /> o= N WORK SHALL BE THE FULL RESPONSIBILITY OF THE CONTRACTOR AND NO ACT, DIRECTION OR REVIEW OF ANY SYSTEM OR 345 N.EI Dorado St., 345 N. EI Dorado St., REVISIONS <br /> z o INT. ELEVATION CALLOUT OX DOOR NUMBER METHOD BY THE ARCHITECT SHALL CHANGE OR AFFECT THE CONTRACTOR'S RESPONSIBILITY IN THIS MATTER. Stockton,CA 95202-1997 Stockton,CA 95202-1997 <br /> C)m W X E X - ELEVATION NUMBER DEFLECTION OF EXISTING TO BE LIMITED TO 1/8"IN ORDER TO MAINTAIN INTEGRITY OF STRUCTURE. Contact:TBD Contact:TBD SHEET INDEX A Q 12/19/2018 Corp Approval Change <br /> Z o AX.X AX.X- SHEET NUMBER <br /> Phone: (209)937-8561 Phone: (209)937-8561 THE FOLLOWING GENERAL CONSTRUCTION ITEMS ARE PART OF THIS PROJECT. THE GENERAL CONTRACTOR SHALL VISIT THE <br /> a AREVISION NUMBER N. NOTHING IN THESE PLANS OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THE MOST Email:TBD Email:TBD SITE AND ASCERTAIN THE EXTENT OF THIS WORK PRIOR TO SUBMITTING BID. <br /> 00 S STRINGENT OF CODES.ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE UNIFORM BUILDING CODE, UNIFORM FIRE <br /> wz <br /> � SHEARWALL CALLOUT CODE(UFC),AND ALL OTHER FEDERAL,STATE,COUNTY AND CITY ORDINANCES. HEALTH <br /> o 1. PREP AND REPAINT ALL EXISTING BOLLARDS ON SITE SAFETY YELLOW.ALL NEW BOLLARDS,AS NOTED ON PLANS,TO BE <br /> 0 ox I XD X - SHEARWALL NUMBER X XXX EQUIPMENT NUMBER San Joaquin County Environmental Health Dept. PAINTED SAME COLOR. <br /> En O X'-X"- SHEARWALL LENGTH 0. COMBUSTIBLE DEBRIS,RUBBISH AND WASTE MATERIAL SHALL NO T BE ACCUMULATED WITHIN BUILDINGS. RUBBISH AND <br /> w U 1868 E. Hazelton Avenue 2. WHERE NEEDED-REPLACE DAMAGED ROOF TILES AND ANY LOOSE OR MISSING GROUT. POWER WASH ALL ROOF TILES. <br /> Q o a EQUIPMENT CALLOUT(M.E.P.) WASTE MATERIAL SHALL BE REMOVED AS OFTEN AS PRACTICAL(ARTICLE 87;UFC). Stockton,CA 95205 3. CLEAN OUT AND SEAL ALL CONCRETE CRACKS LARGER THAN 1/4 THICK AT ALL AREAS INCLUDING CURBS AND GUTTERS. <br /> w z X'_Xr, ELEVATION X X XXXXX - EQUIPMENT Contact:Jeff Carruesco, REHS Program Coordinator 4. WHERE NEEDED-PAINT ALL ON-SITE FENCES AND RAILINGS TO MATCH BUILDING FIELD COLOR(SW#6122,'CAMELBACK) <br /> M <br /> 00 X'-X"- HEIGHT X - FIXTURE NUMBER P. FINAL APPROVAL IS SUBJECT TO ACCEPTANCE AFTER A FIELD INSPECTION. Phone: (209)468 3877 U.O.N. <br /> Q w XXXX XXXX - DESCRIPTION <br /> 0 0� Email:sjcehd.com 5. REMOVE OIL AND OR SODA STAINS IN THE DRIVE THRU AND TRASH ENCLOSURE AREA. . <br /> N > Q. FIRE EXTINGUISHER REQUIREMENTS:A MINIMUM 2A-10BC RATED FIRE EXTINSHER(S)IS(REQUIRED)(RECOMMENDED)FOR 6. PROVIDE STAINLESS STEEL CORNER GUARDS AT MENU BOARD SOFFIT AND WALL NEXT TO THE COUNTER. <br /> `R a CLX CEILING CALLOUT 3000 SQUARE FEET.THE EXTINGUISHER(S)SHRLL BE LOCATED SO THAT IT WILL BE UNNECESSARY FOR A PERSON TO 7. REPLACE KITCHEN CEILING GRID,TILES AND HVAC VENTS. REMOVE AND REPLACE KITCHEN CEILING LIGHTS, UPGRADE TO CLIENT <br /> N wK <br /> CL-X- CEILING TYPE TRAVEL MORE THAN 75 FEET TO REACH THE NEAREST EXTINGUISHERS SHOULD BE MOUNTED ON THE WALL SO THE TOP LED. <br /> o Q X X X'-X"- HEIGHT REFER TO STRUCTURAL, MECHANICAL,PLUMBING,AND OF THE EXTINGUISHER SHOULD BE MOUNTED NEAR EXITS OR IN NORMAL EXIT PATHWAYS. IF NECESSARY,A SIGN SHALL BE PRB MANAGEMENT LLC. <br /> m 8. IN REMODELED INTERIOR AREAS-REPLACE ALL MISCELLANEOUS ACCESSORIES WITH NEW OR CLEAN/REPAIR EXISTING TO <br /> � 0= ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS. POSTED TO CLEARLY INDICATE THE LOCATION OF THE EXTINGUISHER.(SECTION 1002.2 UFC/UFCS 10-1). 'LIKE NEW'CONDITION. INCLUDES BUT NOT LIMITED TO CLEAN OUT COVERS, ELECTRICAL WALL PLATES,SWITCHES,SMOKE 4709 Mangels Blvd. <br /> E w w DETECTORS, FIRE ALARM INDICATORS,CORNER GUARDS, DAMAGED HVAC GRILLES, DAMAGED LIGHT FIXTURES, Farfield,CA 94534 <br /> w GENERAL DRAWING SYMBOLS J GC SHALL VERIFY THESE REQUIREMENTS ARE MET AND REPLACE/PROVIDE EXTINGUISHERS AS REQUIRED BY FIRE THERMOSTAT COVERS/REMOTE SENSORS,STAINLESS STEEL CHASES, FLOOR DRAIN/SINK COVERS,MISSING DOOR DAVE FULWILER <br /> o o DEPARTMENT. <br /> a <br /> HARDWARE,ETC. <br /> 70 Uj <br /> "a 9. SNAKE AND CLEAN OUT FLOOR DRAINS IN TOILET ROOMS. <br /> 70 o`}-` R. PER COUNTY ENVIRONMENTAL HEALTH DEPT.ONE RESTROOM IS TO REMAIN OPEN DURING CONSTRUCTION. 10. REPAIR EXISTING DOOR CLOSERS,WHERE NOTED AS REMAINING,TO OPERATE AT 5#MAX PRESSURE. <br /> rn w en3en ary School Sandman Park CITY CONTACTS GJ PROJECT <br /> E a S. THE GENERAL CONTRACTOR SHALL VERIFY EXISTING HOOD ANSUL SYSTEM IS IN COMPLIANCE WITH CURRENT UL 300 11. REPAIR AND CLEAN EXISTING STOREFRONT DOORS, FRAMES,WEATHER STRIPPING AND GLAZING. <br /> o= White 12. PAINT ALL EXISTING CEILING COMPONENTS(EXCLUDING PARTS THAT ARE NOT TO BE PAINTED SUCH AS CODE ITEMS) TACO BELL REMODEL <br /> 3 U, REQUIREMENTS AND NOTIFY OWNER IF NOT PRIOR TO START OF WORK. <br /> COMPLIANCE REQUIRED ALL TIMES THROUGHOUT CONSTRUCTION UNTIL RTO: BLACK TO MATCH PAINTED CEILING TILE GRID. INCLUDES, BUT NOT LIMITED TO,SPEAKERS, HVAC, REGISTERS,CEILING <br /> o a o V,, 3507 W HAMMER LANE <br /> o 5 � ��a�' 1. SEAL ALL CEILING AND WALL PENETRATION USING COVER PLATES AND FOAM AS NEEDED. OUTLETS, ETC. <br /> T. ALL WORK SHALL BE DONE IN COMPLIANCE WITH CURRENT STATE AND FEDERAL ACCESSIBILITY REQUIREMENTS. REFER STOCKTON,CA 95219 <br /> �I Uj <br /> o x � TO DRAWINGS FOR STANDARD COMPLIANCE REQUIREMENTS ALTHOUGH NOT ALL DETAILS ARE APPLICABLE TO THIS 2. CONTRACTOR TO CONSTRUCT A TEMPORARY PLYWOOD DUST WALL WITH A DOOR BEHIND THE FRONT COUNTER. THIS 13. ALL NEW WALL ELECTRICAL/DATA PLATE COVERS SHALL BE STAINLESS STEEL. <br /> x PROJECT.NOTIFY OWNER OF ANY NON COMPLIANT WORK FOR RESOLUTION PRIOR TO STARTING SUCH WORK. (RTO). <br /> 14. PRICE CONFIRMATION BOARDS(PCB)AT DT&PREPAY WINDOWS WILL BE REMOVED BY OWNER.DISCONNECT/CAP <br /> CDQ Mariners Pointe ��p{40i9¢ F " WALL SHOULD REMAIN IN PLACE UNTIL 3 DAYS PRIOR TO RESTAURANT TURNOVER RTO . ELECTRICAL AND PATCH/PAINT OPENING TO MATCH ADJACENT SURFACES. STORE#2832 <br /> CD z Apartments s <br /> o m fl d° a g - g 3. THE CONTRACTOR SHALL PROVIDE ADEQUATE SEPARATION BETWEEN THE CONSTRUCTION ZONE THE OCCUPIED AREAS, 15. REPLACE SCREENS ON EXISTING EXTERIOR FLY FANS OVER DT AND PREPAY WINDOWS. <br /> U. ALL WORK DESCRIBED HEREIN THESE PLANS,AND OTHER CONTRACT DOCUMENTS,SHALL BE THE RESPONSIBILITY OF THE <br /> w AND SHALL VERIFY THAT NECESSARY CITY INSPECTIONS FOR FIRE STRUCTURAL AND LIFE SAFETY ARE APPROVED PRIOR 16. WHERE(E)CUSTOMER SELF SERVE DRINK TABLE IS TO REMAIN(REFER TO DWG A2)THE GC SHALL CLEAN AND BUFF <br /> 0 <br /> p °'"" GENERAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE(I.E. BY OWNER,OTHERS OR VENDOR). WORK,SUCH TO DAILY OCCUPANCY OF ANY PORTION OF THE BUILDING. STAINLESS STEEL FINISHES. OWNER WILL REPLACE LAMINATE DOORS WITH STAINLESS STEEL DOORS. <br /> Q AS KITCHEN EQUIPMENT, IS SUPPLIED BY OWNER BUT INSTALLED BY CONTRACTOR. OTHER WORK,SUCH AS SIGNAGE, MAY 17. WHERE NEEDED PREP&REPAINT EXISTING TRASH ENCLOSURE AND GATES TO MATCH BUILDING FIELD COLOR(SW#6122, <br /> "i S ""�' BE SUPPLIED AND INSTALLED BY VENDORS BUT REQUIRES WORK BY CONTRACTOR TO COMPLETE. 4. ONE RESTROOM SHALL REMAIN OPERATIONAL DURING CONSTRUCTION FOR EMPLOYEE USE. <br /> o Z w = yh9r a CAMELBACK"). 4Ln��0 <br /> Mo d 5. PARKING LOT AND DRIVE THRU LANE MUST BE KEPT CLEAR OF ALL DEBRIS, NAILS, ETC. 18. REPLACE ALL BROKEN OR DAMAGED WHEEL STOPS IN PARKING AREA AS NOTED ON DWG AO-0. �o n n <br /> CO 0-0 PROJECT SITE is IN ALL SUCH CASES THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING SUCH WORK WITH THE VENDOR(S) LJ�L�L�• <br /> "ttiQ`'' INCLUDING VERIFYING FIELD CONDITIONS AND MEASUREMENTS AND DELIVERY TIMES. 6. STAGING AREA MUST BE KEPT TO THE REAR OF PROPERTY AND IN LIMITED AREA WHEN POSSIBLE. ALL DRIVEWAYS DRIVE <br /> ~� M70H <br /> E m w ""'"'_°"° AISLES AND DRIVE THRU LANE SHOULD REMAIN OPEN AND UNOBSTRUCTED AT ALL TIMES DURING CONSTRUCTION. <br /> 3507 West Hammer Lane ¢ ADDITIONAL CLIENT TOUCH POINTS/SCOPE <br /> _ o a V. ADA REQUIREMENTS:THE COST TO COMPLETE THE PERMITTED WORK EXCEEDS THE CURRENT VALUATION THRESHOLD 7. DRIVE THRU MENU BOARD AND SPEAKER MUST BE FUNCTIONAL AT ALL TIMES DURING CONSTRUCTION AS DRIVE THRU <br /> of o'a W Hammer i W. H A M M E R L A N E,.,,K111,�° ($143,303.00)FOR REMODELS/ALTERATION.GC SHALL CONFIRM THAT THE FOLLOWING ACCESSIBLE FEATURES ARE 100% REMAINS OPEN. 19. DISCUSS IN ADVANCE WITH OWNER: REPAIR,SLURRY AND STRIPE PARKING LOT. <br /> Y Z= COMPLIANT PER 2013 CBC 11B202.4 EXCEPTION 8: 20. REMOVE AND REPLACE KITCHEN CEILING AND LIGHT FIXTURES UPGRADE TO LED. <br /> Z a _ 8. ADJUST EXISTING IRRIGATION SYSTEM AS REQUIRED FOR PROPOSED NEW WORK. INCLUDES REMOVING AND CAPPING <br /> �' uodraea:,. A.PRIMARY ENTRANCES TO AREA OF ALTERATION. 21. ALL ADA UPGRADES BROUGHT UP TO THE CURRENT CODE. <br /> M.1' <br /> � a SPRINKLER HEADS WHERE LANDSCAPING IS NOTED AS BEING REMOVED AND REPLACED WITH PAVEMENT/ROCKS. <br /> 22. POWER STRIPS(ELECTRICAL OUTLETS)IN DINING ROOM FOR CUSTOMER USE.POSITION FOR EASY, NO CEILING OUTLETS. <br /> a Q z Z B. PATH OF TRAVEL TO AREA OF ALTERATION. <br /> i co a S :. 9. ADJUST EXISTING LANDSCAPING IN PLANTER STRIPS AROUND BUILDING SO AS TO BE 4"LOWER THAN EXISTING PLASTER 23. DISCUSS IN ADVANCE WITH OWNER: REMOVE AND REPLACE DAMAGED LANDSCAPE AREAS. <br /> w .c ZC. RESTROOMS SERVING AREA OF ALTERATION. WEEP SCREEDS. NOTIFY OWNER IF THIS CAN NOT BE DONE WITHOUT MODIFYING PLANTERS. 24. PAINT DUMPSTER AND REPLACE GATE IF NECESSARY. <br /> z= 05 <br /> �, 25. REPAIR/REPLACE DAMAGED KITCHEN FLOOR TILES. FILL/REPAIR GROUT AS NEEDED. TITLE SHEET <br /> E z _ v pv„ Jahn R wil�ia D. PARKING,STORAGE,ALARMS SERVING AREA OF ALTERATION. 10. CLEAN OUT AND REPAIR EXISTING ROOF AND OVERFLOW DRAINS FOR POSITIVE DRAINAGE TO DISCHARGE ONTO 26. REPLACE ANY DOUBLE DOORS WITH SINGLE ENTRY T-6"WIDE DOORS <br /> m 010 <br /> _ Elementary5ch PAVEMENT SURFACES AWAY FROM BUILDING. PROVIDE NEW SCREENS ON ROOF. <br /> C ¢� E. NO PUBLIC TELEPHONES OR DRINKING FOUNTAINS ARE PROVIDED OR EXISTING. 27. REPLACE ANY CUSTOMER VISIBLE FRP OR WALL TILE THAT IS DISCOLORED OR IN DISREPAIR(EXCESSIVE HOLES CRACKS, <br /> (a C6O _ 6 Martranrts A:•e <br /> 11. CLEAN EXISTING ROOF AREAS OF ALL DEBRIS OR UNUSED EQUIPMENT.VERIFY WITH OWNER EXTENT OF UNUSED DAMAGED). <br /> CID w w e EQUIPMENT TO BE REMOVED. 28. DUSCUSS IN ADVANCE WITH OWNER: REPLACE LOT LIGHT HEADS WITH LED LIGHTS <br /> 0o <br /> z 30. CAMERA ALL INTERIOR AND EXTERIOR DRAIN LINES. DISCUSS RESULTS WITH OWNER. T1 ■ <br /> 0 <br /> 0 0� <br /> Q VICINITY MAP N.T.S. H GENERAL NOTES IA SPECIFIC REMODEL PREPARATION AND STAGING NOTES B CUSTOMER TOUCH POINTS / SCOPE OF WORK C <br />