My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2200 - Hazardous Waste Program
>
PR0220086
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:24:14 PM
Creation date
8/17/2020 2:34:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0220086
PE
2250
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
847
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Structural Analysis 84552 <br /> Tank Design Information <br /> Tank IMT 1550 SG Min Required Thickness <br /> Primary I Crosslink 1.90 0.39 <br /> Secondary I Crosslink 1.90 0.42 <br /> Fluid 1.26 <br /> Lugs 3 <br /> Anchors 7/8 inch Diameter 4 inch Embed <br /> Hilti HIT-RE 500 with <br /> ASTM A 193 B7 threaded rod 6 total <br /> Loading <br /> Pg 0.00 psf Live Load 20 psf <br /> Pf 0.00 psf Dead Load 800 lb <br /> Sds 1.146 Wind 115 MPH <br /> Sd1 0.493 <br /> V 10.10 k <br /> Code Specifications <br /> IBC IBC 2012 <br /> ASCE ASCE 7-10 <br /> Material Specifications <br /> Cross-Linkable High Density Polyethylene Tensile Yield Strength 2800 psi <br /> Linear Low Density Polyethylene Tensile Yield Strength 2600 psi <br /> Lugs Linear Low Density Polyethylene <br /> Anchor Bolts Hilti HIT-RE 500 V3 <br /> Cables 3/16" diameter with a breaking strength of 3210 lb. <br /> Design Notes <br /> * Design pressures are based on environmental loads and fluid pressures only! <br /> * Assumed 2000 psi concrete <br /> * Tanks assumed to be in continuous contact with the foundation. <br /> * Design Calculations based on new condition. <br /> * Anchor bolt recommendations based on minimum requirements <br /> * Final anchor bolt design by GC/Engineer Of Record based on site conditions. <br /> Page 2 of 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.