11 <br /> Hilti PROFIS Engineering 3.0.56 <br /> www.hilti.com <br /> Company: Page: 8 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: Shear Loading Date: 2/13/2020 <br /> Fastening point: <br /> 6 Warnings <br /> • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations(AS 5216:2018, ETAG 001/Annex C, <br /> EOTA TR029 etc.).This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered-the <br /> anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the design loading.PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br /> • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential <br /> concrete failure prism into the structural member.Condition B applies where such supplementary reinforcement is not provided,or where pullout <br /> or pryout strength governs. <br /> • Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the <br /> Evaluation Service Report for cleaning and installation instructions. <br /> • For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ <br /> • An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14,Chapter 17,Section <br /> 17.2.3.4.3(a)that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the <br /> case,the connection design(tension)shall satisfy the provisions of Section 17.2.3.4.3(b),Section 17.2.3.4.3(c),or Section 17.2.3.4.3(d).The <br /> connection design(shear)shall satisfy the provisions of Section 17.2.3.5.3(a),Section 17.2.3.5.3(b),or Section 17.2.3.5.3(c). <br /> • Section 17.2.3.4.3(b)/Section 17.2.3.5.3(a)require the attachment the anchors are connecting to the structure be designed to undergo ductile <br /> yielding at a load level corresponding to anchor forces no greater than the controlling design strength.Section 17.2.3.4.3(c)/Section 17.2.3.5.3 <br /> (b)waive the ductility requirements and require the anchors to be designed for the maximum tension/shear that can be transmitted to the <br /> anchors by a non-yielding attachment.Section 17.2.3.4.3(d)/Section 17.2.3.5.3(c)waive the ductility requirements and require the design <br /> strength of the anchors to equal or exceed the maximum tension/shear obtained from design load combinations that include E,with E increased <br /> by wo. <br /> • Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. Reference ACI 318-14, <br /> Section 17.8.1. <br /> • The characteristic bond resistances depend on the return period(service life in years):50 <br /> • Please be aware that with TE 70 hmin>_0.000 in.as per the ESR. <br /> Fastening meets the design criteria! <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROMS Engineering(c)2003-2019 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 8 <br />