My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14700
>
2200 - Hazardous Waste Program
>
PR0220086
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/29/2021 6:24:14 PM
Creation date
8/17/2020 2:34:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0220086
PE
2250
FACILITY_ID
FA0006674
FACILITY_NAME
OWENS-BROCKWAY GLASS CONTAINER INC
STREET_NUMBER
14700
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
209-240-24
CURRENT_STATUS
01
SITE_LOCATION
14700 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
847
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q I I I Irl Environmental Health Department <br /> C C u N T AMENDED <br /> 8/10/2020 <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> OWENS-BROCKWAY GLASS CONTAINER INC 1 14700 W SCHULTE RD,TRACY August 10, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and <br /> evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those <br /> persons directly responsible for gathering the information,the information submitted is,to be the best of my <br /> knowledge and belief,true, accurate, and complete. I am aware that there are significant penalties for submitting <br /> false information, including the possibility of fine and imprisonment for knowing violations. <br /> Title 22 California Code of Regulations section 66265.192(k) <br /> The tank system assessment shall include all of the following information: <br /> (1)tank configuration (i.e., horizontal,vertical), material of construction, and gross capacity(in gallons); <br /> (2)design standard(s), if available, according to which the tank and ancillary equipment were or will be constructed <br /> and all of the following information: <br /> (A)material of construction; <br /> (B)material thickness and the method used to determine the thickness; <br /> (C)description of tank system piping (material, diameter); <br /> (D)description of any internal and external pumps; and <br /> (E)sketch or drawing of tank including dimensions. <br /> (3)documented age of the tank system (if tank was previously used), if available, (otherwise, an estimate of the <br /> age); <br /> (4)description and evaluation of any leak detection equipment; <br /> (5)description and evaluation of any corrosion protection equipment, devices, or material; <br /> (6)description and evaluation of any spill prevention or overfill equipment; <br /> (7)description and evaluation of secondary containment for the tank system (secondary containment must meet <br /> minimum standards as specified in subsections 0)(1)through 0)(3)of this section)including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265.193(f); <br /> (8)hazardous characteristics of the waste(s)that have been or will be handled; <br /> (9)prior to placing a new tank system or component in use, an independent, qualified installation inspector or an <br /> independent, qualified, professional engineer, registered in California, either of whom is trained and experienced in <br /> the proper installation of tank systems, shall inspect the system or component for the presence of any of the <br /> following items and document in writing the results of the inspection: <br /> (A)weld cracks or breaks; <br /> (B)scrapes of protective coatings; <br /> (C)corrosion; <br /> (D)any structural damage or inadequate construction or installation such as cracks, punctures, damaged fittings.All <br /> discrepancies shall be documented in the assessment and remedied before the tank system is placed in use. <br /> (10)all new tanks and ancillary equipment shall be tested for tightness prior to being placed in use.The results of <br /> the test(s)shall be documented in this assessment.Tank system integrity or leak test requirements must be in <br /> compliance with all local requirements. Prior to conducting a tank system integrity test or leak test, contact local <br /> agency staff for local requirements. <br /> (11)estimated remaining service life of the tank system based on findings of subsections (k)(1)through (k)(10). <br /> Title 22 California Code of Regulations section 66265.1920) <br /> (1)tank system must have secondary containment capable of containing 100 percent of the contents of the tank <br /> and ancillary piping volume; and <br /> (2)if the tank system is exposed to precipitation,the secondary containment system must have sufficient capacity, <br /> in addition to that required in subsection 0)(1)of this section,to contain run-on and infiltration from a 25-year, <br /> 24-hour rainfall event; <br /> (3)tank system secondary containment shall be provided with a leak detection system that is designed and <br /> FA0006674 PR0220086 SCO01 08/10/2020 <br /> EHD 22-03 Rev.9/20/2019 Page 9 of 13 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.