Laserfiche WebLink
MIN. 2-#8 METAL SCREWS �� 362VS125-33 w <br /> DIAGONAL BRACING <br /> SPACED ® 48" O.C. <br /> 362VS125-33 ® 16" 2 - <br /> MAXIMUM 1/2 GRATE 1 STAGGERED SEE Q <br /> OPENING O.C. (WH. OCCURS) - I DETAIL m ,1 <br /> FLOOR BEYOND I ` 3cn <br /> 00 o <br /> SET DRAIN TO ALLOW DOOR - z m o 0 <br /> FOR 1/2" QUARRY TILE CO � o 0 <br /> 1/8" PER FT. SLOPE SLOPE GYP. BD. CEILING (�_ _ _% SUSPENDED O <br /> �_ WHERE OCCURS ACOUSTICAL CEILING <br /> > LARR #2404 WH. OCCURS <br /> u ° ° <br /> EXTRUDED ALUM PROVIDE MTL STOP & CONT @g <br /> SEALANT GYP. BDMTL STUD FRAMING, <br /> . CEILING SJB Brands, LLC <br /> THRESHOLD SET IN EXTEND 6" ABOVE � 17915 SKY PARK CIRCLE, SUITE J, <br /> 5/8" TYPE CONT. SEALANT BED 14 <br /> BID. EA SIDE X GYP. CEILING HEIGHT Z TEL: (949 )475 0VINE, CA 146 <br /> D p D D <br /> 3-5/8" X 25 GA. FAX:(949)475-0137 <br /> "HILTI" POWER-DRIVEN PINS METAL STUDS @ 16" Uj <br /> 24" O.C. MAX. TYP. U.N.O. O.C. (U.N.O.) "CEMCO" N <br /> FLOOR DRAIN PER ICC-ES ESR-1663 METAL STUDS/VIPER THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND <br /> PLUMBING DRAWINGS AND <br /> CONCRETE FLOOR SLAB 2 STUDS ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN <br /> (EXISTING TO REMAIN OR SPECIFICATIONS a 1 w LARR #25646 ICC-ESR 2620 THE PROPERTY OF GARY WANG & ASSOCIATES; AND NO PART <br /> SAW-CUT AND FILL AS FLOOR LINE THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN <br /> FLOOR FINISH AS SCHEDULED CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE <br /> NECESSARY FOR SLOPE) ©JBASE AS SCHEDULED <br /> \Q _ N SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND <br /> N Q cV a DEVELOPED WITHOUT THE WRITTEN CONSENT OF GARY WANG & <br /> \g a ASSOCIATES. VISUAL CONTACT WITH THESE DRAWINGS AND <br /> a SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF <br /> THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS <br /> SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; <br /> FLOOR DRAIN - SECTI_____(::ON 9 TYPICAL T H E R S H OL D 9 TY P. NON-BEARING PARTITION - SECTION CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL <br /> DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE <br /> MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS <br /> SCALE: 1 1/2"=1'-D" 1/2 SCALE: N.T.S. AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAIL MUST <br /> METAL STUDS: DIETRICH, ESR-1166P BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING <br /> WITH THE FABRICATION. <br /> COLD STORAGE ROOM METAL STUDS: VIPER STUDS <br /> RAISED CURB (IF ANY) BY CEMCO 362VS125-33 METAL ARCHITECT <br /> ------------ ICC-ESR 2620 STUD BRACE AT 48' O.C. <br /> -- -------------- ---- - ALT. DIRECTION. PROVIDE <br /> N - STRONG BACK WHERE <br /> a LENGTH EXCEEDS 10'-0" GARY WANG <br /> / &ASSOCIATES, INC. <br /> FINISHED FLOOR / a <br /> VERIFY WITH FLOOR SINK / <br /> LOCAL CODE // / 1000 Corporate Center Dr., Suite 550 <br /> Monterey Park, CA 91754 <br /> TEL: (626)288-6898 FAX: (626) 768-7101 <br /> EXISTING SLAB ON GRADE TO REMAIN "P" TRAP // // CLIP ANGLE WITH http://www.garywang.com <br /> MINIMUM 2—#10 <br /> / SHT. MTL. SCREWS <br /> + + / <br /> RAISED CURB (IF ANY) <br /> #10 HILTI KWIK <br /> PRO-SELF DRILLING STAMP <br /> PROVIDE EDGE METAL AT z SCREW AT EA. STUD. <br /> TOP EDGE OF GYP. BD. LARR#25678 <br /> Amh I? <br /> ICC-ESR-2196 <br /> p� z MTL. TOP TRACK <br /> ~ J I GYP. BD. WHERE SED ARj- <br /> 00o o g R-13 INSUL. WHERE WALL OCCURS LARR #2404 _V��r `� Hg <br /> 1w _j CDOCCURS BTWN. COND. AND I MTL. STUD <br /> " 1'-0', o0 � UNCOND. SPACE * N . C32569 <br /> CP RE .04- - 019 <br /> FLOOR SINK NOT USED WALL ATTACHMENT 9'Fo �F�� <br /> F <br /> SCALE:N.T.S. SCALE:N./A. SCALE: N.T.S. CAL <br /> METAL STUDS: DIETRICH, ESR-1166P <br /> KITCHEN SERVICE 3-#10 SHT. MTL. SCREW PRE DRILL (E) FRAMING <br /> WHERE NECESSARY TO AVOID SPLITTING <br /> WALL FINISH 7 <br /> (N) COOOLER PROJECT NAME/ADDRESS: <br /> WALL FINISH METAL STUD (SEE SCHEDULES) <br /> (SEE SCHEDULE) SILICONE JOINT SEALANT WALL <br /> FINISH FINISH • JUICE IT U P! <br /> (N) 16 GA <br /> SILICONE JOINT SEALANT . (SEE ELEVATIONS) <br /> (SEE ELEVATIONS) RIPON TOWN SQUARE <br /> 1 -1/4"X2" <br /> GALV. @ 24" CONDITION A 1201 W. MAIN ST. <br /> O.C. ANGLE W/ 3/8" RADIUS QUARRY MTL. STUD BRACE ' <br /> "HILTI" POWER DRIVEN PINS 1/4" SCREW @ TILE COVE BASE BY (FRAMING PERP. TO RIPON, CA 95366 <br /> ® 24 O.C. MAX. TYP. U.N.O. NOTE: 24" O.C. U.N.O. KITCHEN EQUIP. WALL) <br /> ESR # 1663 WATER PROOFING CONTRACTOR 3-#10 SHT. MTL. SCREW PRE DRILL 2x BLKG. <br /> REQUIREMENT FLOOR AS SCHEDULED <br /> 8" UP WALL WHERE NECESSARY TO AVOID SPLITTING <br /> 24" OUT ON FLOOR TYP. (E) FRAMING REVISIONS: <br /> SLOPE FOR SLOPE FOR - <br /> POSITIVE DRAINAGE POSITIVE DRAINAGE - <br /> 1/2" IN 24" TYP. a _ <br /> a <br /> a a - <br /> a a <br /> a <br /> a a a a <br /> d d Q — <br /> 4 a a HILTI SHOT PINS (2)-0.145" CONDITION B 6 _ <br /> DIAM. X 1-1/4" EMBED. @ 24" (FRAMING PERP. TO <br /> "CEMCO METAL STUDS" O.C. (ICC ESR-1663) MTL. STUD BRACE WALL) <br /> ISSUE DATE: <br /> BASE-SECTION N WALK-IN COOLER BASE 7 WALL ATTACHMENT DETAIL ^ 1ST — <br /> SCALE: N.T.S. SCALE: 1 "=1'-0" SCALE: N.T.S. 3 2ND — <br /> 3RD — <br /> 4TH — <br /> COLD STORAGE ROOM <br /> #10X1" LNG TEK <br /> SCREW TO B.O. BLK'G 6TH <br /> @ 12" O.C. TYP. <br /> 2x4 WOOD STUDS AT JAMB 5-3/4" X 2 METAL ROOF <br /> EXISTING FLOOR JOB NUMBER <br /> & HEAD W/ ANCHOR FRAME r--------- I ROOF/ <br /> FLOOR <br /> EVAPORATOR COIL <br /> 1 . I I WOOD JOIST TO REMAIN, <br /> 2 X WD. I TYR <br /> L--- ---J BLOCKING362T125-33 CONT. ARCH PROJECT#: 18-287 <br /> I I <br /> TOP TRACK W/ <br /> 1" CLEARANCE BETWEEN <br /> DRAIN LINE & C.S.R. WALL METAL STUD (1)-#10 TEK SCREW <br /> ON EA. SIDE OF DRAWN BY CHECKED BY <br /> DRAINLINE O SLIP TRACK PERPENDICULAR TO JOIST TRACK/BRACE AT EA. <br /> WOOD DOOR (CLAMPED TO WALL) BY G.C. GENERAL CONTR. TO UD © 24" O.C. JR ADR <br /> DRAINLINE PITCH 1/4" PROVIDE WALL SLEEVES <br /> PER LIN. FOOT AT LOCATIONS INDICATED EXISTING ROOF/FLOOR SHEET CONTENT <br /> ON PLAN WOOD JOIST TO <br /> REMAIN, TYP. <br /> Ln <br /> DETAILS <br /> 2 X WD. 362T125-33 CONT. TOP <br /> BLOCKING TRACK W/ (1)-#10 TEK <br /> LjZ #10X1" LNG TEK SCREW ON EA. SIDE OF SHEET NO <br /> GYPSUM BOARD FINISHED FLOOR SCREW TO B.O. METAL TRACK/BRACE AT EA. STUD <br /> FLOOR SINK SEE PLUMBING BLK'G Co? 12" STUD @ 24" O.C. <br /> PLAN FOR LOCATION O.C. TYP. <br /> O SLIP TRACK PARALLEL TO JOIST F.F. <br /> A� 300 <br /> TYPICAL DOOR-PLAN 12 COOLER CONDENSTATE DRAIN 8 STEEL FRAMING PARALLEL TO WOODEN ROOF TRUSS 4 <br /> SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. <br />