PLUMBING LEGEND PLUMBING FIXTURE SCHEDULE PLUMBING GENERAL NOTES
<br /> W W SANITARY WASTE PIPE CONNECTION 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL, STATE CODES & 2016 CPC.
<br /> GW GW GREASE WASTE SYMBOL FIXTURE TYPE DESCRIPTION 2. COORDINATE ALL WORK WITH ALL OTHER TRADES AND CONTRACTORS.
<br /> WASTE VENT CW HW 3. THE PLUMBING CONTRACTOR SHALL VERIFY THE EXACT LOCATION, DEPTH AND ° o
<br /> SD SD STORM DRAIN ��
<br /> O o
<br /> 11 AMERICAN STANDARD CADET 3, 3378.128ST ADEQUACY OF ALL SERVICES BEFORE STARTINGAND SHALL NOTIFY THE GENERAL
<br /> -- - V - -- V SANITARY VENT WC-1 WATER CLOSET 3 2 1/2" - FLOOR MOUNTED, FLUSH TANK 1.28 GPF CONTRACTOR IF SAID CONNECTION ARE NOT IN THE LOCATION SHOWN OR ARE NOT
<br /> ---FV- -- FV FOOT VENT (ADA) ELONGATED BOWL, OPEN FRONT SEAT OF SUFFICIENT SIZE OR DEPTH TO MAKE THIS CONNECTION IN COMPLIANCE WITH 0
<br /> AMERICAN STANDARD 0356.421 (SINK), 1340.107 (FAUCET) THIS PLAN.
<br /> D D INDIRECT DRAIN 1 4. THE PLUMBING CONTRACTOR SHALL APPLY AND PAY FOR ALL NECESSARY PERMIT.
<br /> LL1 LAVATORY 2 1 1/2 1/2,> PROVIDE POWERS TEMPERING VALVE LFe480 (ABBE 1070) TO SJB Brands, LLC
<br /> CW DOMESTIC COLD WATER (ADA) LIMIT HOT WATER TO 1 10°F MAX., 0.5 GPM ARRANGE WITH UTILITY COMPANIES TO CONNECT ALL UTILITY TO SITE. 17915 SKY PARK CIRCLE, SUITE J,
<br /> 5. THESE PLAN INDICATE APPROXIMATE EQUIPMENT DIMENSION ONLY. EXACT IRVINE, CA 92614
<br /> - -- HW DOMESTIC HOT WATER DIMENSIONS MUST BE OBTAINED FROM THE EQUIPMENT MANUFACTURER. TEL: (949) 475-0146
<br /> -- -- - HWR DOMESTIC HOT WATER RETURN S-1 3 COMP. SINK 2" 2" 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE 6. THE PIPING SHOWN ON PLANS IS SCHEMATIC ONLY. INSTALL PIPING TO SUIT THE FAX:(949)475-0137
<br /> STRUCTURAL CONDITIONS. PROVIDE ALL NECESSARY OFFSETS AS REQUIRED. VERIFY
<br /> G G NATURAL GAS WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND MECHANICAL DRAWINGS.
<br /> S-2 PREP SINK FS - 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
<br /> CD CD CONDENSATE DRAIN 7. CONTRACTOR SHALL PROVIDE ALL STOPS, COCKS, VALVES, INDIRECT WASTE LINES, ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN
<br /> ACCESS PANELS, ETC. TO ASSURE AN APPROVED ACCEPTABLE PLUMBING SYSTEM. THE PROPERTY OF GARY WANG & ASSOCIATES; AND NO PART
<br /> OD OD OVERFLOW DRAIN THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN
<br /> PROVIDE AND INSTALL NEW TEES, WYES OR ELLS AT EACH GAS, WATER OR SEWER CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
<br /> SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND
<br /> - - COTG CLEANOUT TO GRADE PER KITCHEN EQUIPMENT SCHEDULE POINT OF CONNECTION. DEVELOPED WITHOUT THE WRITTEN CONSENT OF GARY WANG &
<br /> MS-1 MOP SINK 3 2 12 12
<br /> / / W/ VACUUM BREAKER ASSEMBLY 8. ALL PLUMBING VENTS THROUGH ROOF SHALL TERMINATE NOT LESS THAN TEN (10) ASSOCIATES. VISUAL CONTACT WITH THESE DRAWINGS AND
<br /> FCO FLOOR CLEANOUT SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
<br /> FEET FROM OR THREE (3) FEET ABOVE ANY FRESH AIR INTAKE. THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS
<br /> I WCO WALL CLEANOUT WALL HUNG HAND SINK SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS;
<br /> 1 9. HOSE BIBBS SHALL BE PROTECTED BY THE APPROVED VACUUM BREAKERS OR CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL
<br /> HS-1 HAND SINK 2" 1k 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE NONREMOVABLE TYPE BACKFLOW PREVENTION DEVICES & INSTALLED + 12" ABOVE DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE
<br /> SOV SHUT-OFF VALVE POWERS TEMPERING VALVE LFe480 TO MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS
<br /> LIMIT HOT WATER TO 120°F MAX. FINISHED FLOOR OR FINISHED GRADE. AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAIL MUST
<br /> GAS SHUT-OFF VALVE BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING
<br /> COUNTERTOP HAND SINK 10. CLEANOUTS SHALL BE INSTALLED IN COMPLIANCE WITH SECTION 707 AND 719 OF WITH THE FABRICATION.
<br /> 1 "
<br /> 8 POC POINT OF CONNECTION HS-2 HAND SINK 2" 1k 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE THE UNIFORM PLUMBING CODE.
<br /> POWERS TEMPERING VALVE LFe480 TO 11. INSULATE HW RUNOUTS TO LAVATORIES SPECIFICALLY UNDER LAVATORIES EXPOSED ARCHITECT
<br /> WC - 1 PLUMBING FIXTURE DESIGNATION LIMIT HOT WATER TO 1207 MAX. PIPING. SPACE UNDER LAVATORIES SHALL BE FREE OF SHARP OBJECTS TO PREVENT
<br /> PLUMBING EQUIPMENT DESIGNATION FD-1 FLOOR DRAIN 2 1% 1/2" - ZURN ZN415B INJURY TO HANDICAPPED.
<br /> I I FD FLOOR DRAIN T.P. W/ TRAP PRIMER CONNECTION 12. EACH HOT WATER HEATER SHALL HAVE A SHUT-OFF VALVE AND FLEXIBLE WATER GARY WANG
<br /> CONNECTORS AT BOTH INLET & OUTLET CONNECTIONS, AND SHALL ALSO HAVE A7'd
<br /> ® FS FLOOR SINK COMBINATION PRESSURE, TEMPERATURE RELIEF VALVE, WITH DISCHARGE PIPED &ASSOCIATES, INC.
<br /> ( E ) EXIST'G EXISTNG FS-1 FLOOR SINK 3" 2„ - - ZURN ZN1900 TO FLOOR SINK.
<br /> 13. SEAL ALL OPENINGS AROUND PIPES PENETRATING THE FIRE RATED WALLS WITH E 1000 Corporate Center Dr., Suite 550
<br /> N ) NEW APPROVED FIRE RETARDING MATERIALS. Monterey Park, CA 91754
<br /> R RELOCATE TP-114. GAS APPLIANCES TO HAVE INTERMITTENT IGNITION DEVICES. TEL: (626)288-6898 FAX: (626)768-7101
<br /> TRAP PRIMER - - 1/2" - PRECISION PLUMBING PRODUCTS http://www.garywang.com
<br /> 15. INSTALL GAS VALVES AND FLEXIBLE CONNECTORS AT EACH GAS APPLIANCE PER
<br /> YB YARD BOX
<br /> CODE.
<br /> ABV ABOVE AO SMITH DEN-52, 50 GALLONS STORAGE CAPACITY 16. NOT USED.
<br /> VCP VITRIFIED CLAY PIPE WH-1 WATER HEATER - - - - 12 KW INPUT (SIMULTANEOUS WIRING), 208V-30 17. ALL SINKS MUST BE EQUIPPED WITH HOT & COLD WATER DISPENSED FROM STAMP
<br /> 61 GPH RECOVERY AT 80' RISE MIXING FAUCETS.
<br /> VTR VENT THRU. ROOF 18. ALL THREADED WATER OUTLETS SHALL HAVE AN APPROVED VACUUM BREAKER
<br /> CLG CEILING PROPERLY INSTALLED.
<br /> 19. ALL NECESSARY PLUMBING CONNECTIONS TO FIXTURE AND EQUIPMENT TO BE
<br /> AP ACCESS PANEL MADE BY THE RESPECTIVE PLUMBING CONTRACTORS. USED AR�Hi
<br /> IE INVERT ELEVATION 20. CONTRACTOR TO LABEL ALL FIXTURE UNITS THAT REQUIRE A BACKFLOW PREVENTION
<br /> DEVICE BY LOCAL CODE.
<br /> B.G. BELOW GRADE 21. ALL WASTE & GAS VENTS ARE TO BE KEPT 5' FROM PROPERTY LINE, AT POINT * No. C32569
<br /> _ cnRE .04-3D-.2,019
<br /> _
<br /> ASO AUTOMATIC SHUT OFF VALVE OF ROOF PENETRATIONS. �64 - 019 Q
<br /> 22. PLUMBING FIXTURES SHALL BE AMERICAN STANDARD, KOHLER, OR EQUAL. ~� 9l,
<br /> GPR GAS PRESSURE REGULATOR 23. ALL A/C CONDENSATE LINE TO BE INSTALLED BY PLUMBING CONTRACTOR. REFER or
<br /> RPPBP REDUCED PRESS. PRINCIPLE BACKFLOW PREVENTER TO MECHANICAL DRAWINGS FOR LOCATION OF CONDENSATE.
<br /> MG MEDIUM PRESSURE GAS 24. INSTALL EXPANSION JOINTS IN THE VENT, WASTE, SOIL PIPING, AND EXPANSION
<br /> LOOPS IN THE WATER AND GAS PIPING AS REQUIRED BY THE LOCAL ADMINISTRA-
<br /> TIVE AUTHORITY.
<br /> 25. CONNECTIONS BETWEEN TWO DISSIMILAR METAL PIPES SHALL BE MADE OF WITH PROJECT NAME/ADDRESS:
<br /> DIELECTRIC UNIONS.
<br /> 26. PLUMBING CONTRACTOR SHALL COORDINATE HIS WORK CAREFULLY WITH THE AIR
<br /> CONDITIONING AND ELECTRICAL CONTRACTORS TO AVOID INTERFERENCES. JUICE IT UP!
<br /> PIPE MATERIAL SCHEDULE 27. ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND RIPON TOWN SQUARE
<br /> ALL EXPOSED PIPING SHALL BE RUN HIGH AS POSSIBLE AND TIGHT TO WALLS.
<br /> 28. SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE OR PLAN REQUIREMENTS 1201 W. MAIN ST.,
<br /> SERVICE UNDERGROUND ABOVE GROUND VERIFY WITH ENGINEER WHEN IN DOUBT. RIPON, CA 95366
<br /> 29. PLUMBING CONTRACTOR TO BE RESPONSIBLE FOR REMOVAL OF EXISTING
<br /> HARD TEMPER, COLD DRAWN COPPER HARD TEMPER, COLD DRAWN COPPER
<br /> COLD & HOT WATER TUBE TYPE "K" TUBE TYPE "L„ UNUSED PLUMBING FIXTURES, PIPING, VALVES, FITTINGS, ETC. PATCH & CAP
<br /> OFF THE EXISTING SYSTEM WHERE IT APPLIES.
<br /> SANITARY WASTE CAST IRON/ABS CAST IRON/ABS REVISIONS:
<br /> 30. WATER SUPPLY CONNECTIONS TO EQUIPMENT, APPLIANCES AND FIXTURES SHALL Q _
<br /> BE PROVIDE WITH A SHUTOFF VALVE. CROSS-CONNECTION SHALL BE PROVIDED IN
<br /> SANITARY VENT CAST IRON/ABS CAST IRON/ABS ACCORDANCE WITH CPC SEC. 603.0. D -
<br /> 31. ALL SANITARY SEWER PIPING IS TO BE SLOPED A MINIMUM OF 2% (1/4" PER FOOT)
<br /> GAS BLACK STEEL, SCHEDULE 40 UNLESS SPECIFICALLY APPROVED BY THE AUTHORITY HAVE JURISDICTION. (CPC 708.1) ® -
<br /> A -
<br /> HARD TEMPER, COLD DRAWN COPPER © -
<br /> INDIRECT DRAIN TUBE TYPE "M" 8
<br /> ISSUE DATE:
<br /> 1ST -
<br /> CONSTRUCTION NOTES. 2ND -
<br /> 3RD -
<br /> 1 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING THIS JOB TO 4TH -
<br /> 5TH
<br /> FAMILIARIZE HIMSELF AS TO THE EXTENT OF WORK REQUIRED, AND EXISTING
<br /> 6TH
<br /> CONDITION, AND SHALL TAKE THESE INTO CONSIDERATION IN THE COST OF
<br /> HIS BID.
<br /> 2. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE JOB NUMBER
<br /> UTILITIES BEFORE STARTING TRENCHING WORK.
<br /> 3. CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL ARCH PROJECT#: 18-287
<br /> PERMITS & PAYING ALL FEES REQUIRED FOR WORK SHOWN ON
<br /> THESE DRAWINGS.
<br /> 4• THE DRAWINGS ARE DIAGRAMMATIC. THE LOCATION OF THE DRAWN BY CHECKED BY
<br /> PIPING IS APPROX. COORDINATE THE LOCATION OF PIPING WITH JR ADR
<br /> OTHER TRADES. ANY CONFLICTS WITH OTHER TRADES
<br /> SHALL BE RESOLVED PRIOR TO INSTALLATION. SHEET CONTENT
<br /> GENERAL NOTES,
<br /> LEGENDS
<br /> AND SCHEDULE
<br /> SHEET NO