PLUMBING LEGEND PLUMBING FIXTURE SCHEDULE PLUMBING GENERAL NOTES <br /> W W SANITARY WASTE PIPE CONNECTION 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL, STATE CODES & 2016 CPC. <br /> GW GW GREASE WASTE SYMBOL FIXTURE TYPE DESCRIPTION 2. COORDINATE ALL WORK WITH ALL OTHER TRADES AND CONTRACTORS. <br /> WASTE VENT CW HW 3. THE PLUMBING CONTRACTOR SHALL VERIFY THE EXACT LOCATION, DEPTH AND ° o <br /> SD SD STORM DRAIN �� <br /> O o <br /> 11 AMERICAN STANDARD CADET 3, 3378.128ST ADEQUACY OF ALL SERVICES BEFORE STARTINGAND SHALL NOTIFY THE GENERAL <br /> -- - V - -- V SANITARY VENT WC-1 WATER CLOSET 3 2 1/2" - FLOOR MOUNTED, FLUSH TANK 1.28 GPF CONTRACTOR IF SAID CONNECTION ARE NOT IN THE LOCATION SHOWN OR ARE NOT <br /> ---FV- -- FV FOOT VENT (ADA) ELONGATED BOWL, OPEN FRONT SEAT OF SUFFICIENT SIZE OR DEPTH TO MAKE THIS CONNECTION IN COMPLIANCE WITH 0 <br /> AMERICAN STANDARD 0356.421 (SINK), 1340.107 (FAUCET) THIS PLAN. <br /> D D INDIRECT DRAIN 1 4. THE PLUMBING CONTRACTOR SHALL APPLY AND PAY FOR ALL NECESSARY PERMIT. <br /> LL1 LAVATORY 2 1 1/2 1/2,> PROVIDE POWERS TEMPERING VALVE LFe480 (ABBE 1070) TO SJB Brands, LLC <br /> CW DOMESTIC COLD WATER (ADA) LIMIT HOT WATER TO 1 10°F MAX., 0.5 GPM ARRANGE WITH UTILITY COMPANIES TO CONNECT ALL UTILITY TO SITE. 17915 SKY PARK CIRCLE, SUITE J, <br /> 5. THESE PLAN INDICATE APPROXIMATE EQUIPMENT DIMENSION ONLY. EXACT IRVINE, CA 92614 <br /> - -- HW DOMESTIC HOT WATER DIMENSIONS MUST BE OBTAINED FROM THE EQUIPMENT MANUFACTURER. TEL: (949) 475-0146 <br /> -- -- - HWR DOMESTIC HOT WATER RETURN S-1 3 COMP. SINK 2" 2" 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE 6. THE PIPING SHOWN ON PLANS IS SCHEMATIC ONLY. INSTALL PIPING TO SUIT THE FAX:(949)475-0137 <br /> STRUCTURAL CONDITIONS. PROVIDE ALL NECESSARY OFFSETS AS REQUIRED. VERIFY <br /> G G NATURAL GAS WITH ARCHITECTURAL, STRUCTURAL, ELECTRICAL AND MECHANICAL DRAWINGS. <br /> S-2 PREP SINK FS - 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND <br /> CD CD CONDENSATE DRAIN 7. CONTRACTOR SHALL PROVIDE ALL STOPS, COCKS, VALVES, INDIRECT WASTE LINES, ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN <br /> ACCESS PANELS, ETC. TO ASSURE AN APPROVED ACCEPTABLE PLUMBING SYSTEM. THE PROPERTY OF GARY WANG & ASSOCIATES; AND NO PART <br /> OD OD OVERFLOW DRAIN THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN <br /> PROVIDE AND INSTALL NEW TEES, WYES OR ELLS AT EACH GAS, WATER OR SEWER CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE <br /> SPECIFIC PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND <br /> - - COTG CLEANOUT TO GRADE PER KITCHEN EQUIPMENT SCHEDULE POINT OF CONNECTION. DEVELOPED WITHOUT THE WRITTEN CONSENT OF GARY WANG & <br /> MS-1 MOP SINK 3 2 12 12 <br /> / / W/ VACUUM BREAKER ASSEMBLY 8. ALL PLUMBING VENTS THROUGH ROOF SHALL TERMINATE NOT LESS THAN TEN (10) ASSOCIATES. VISUAL CONTACT WITH THESE DRAWINGS AND <br /> FCO FLOOR CLEANOUT SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF <br /> FEET FROM OR THREE (3) FEET ABOVE ANY FRESH AIR INTAKE. THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS <br /> I WCO WALL CLEANOUT WALL HUNG HAND SINK SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS; <br /> 1 9. HOSE BIBBS SHALL BE PROTECTED BY THE APPROVED VACUUM BREAKERS OR CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL <br /> HS-1 HAND SINK 2" 1k 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE NONREMOVABLE TYPE BACKFLOW PREVENTION DEVICES & INSTALLED + 12" ABOVE DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE <br /> SOV SHUT-OFF VALVE POWERS TEMPERING VALVE LFe480 TO MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS <br /> LIMIT HOT WATER TO 120°F MAX. FINISHED FLOOR OR FINISHED GRADE. AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAIL MUST <br /> GAS SHUT-OFF VALVE BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING <br /> COUNTERTOP HAND SINK 10. CLEANOUTS SHALL BE INSTALLED IN COMPLIANCE WITH SECTION 707 AND 719 OF WITH THE FABRICATION. <br /> 1 " <br /> 8 POC POINT OF CONNECTION HS-2 HAND SINK 2" 1k 1/2" 1/2" PER KITCHEN EQUIPMENT SCHEDULE THE UNIFORM PLUMBING CODE. <br /> POWERS TEMPERING VALVE LFe480 TO 11. INSULATE HW RUNOUTS TO LAVATORIES SPECIFICALLY UNDER LAVATORIES EXPOSED ARCHITECT <br /> WC - 1 PLUMBING FIXTURE DESIGNATION LIMIT HOT WATER TO 1207 MAX. PIPING. SPACE UNDER LAVATORIES SHALL BE FREE OF SHARP OBJECTS TO PREVENT <br /> PLUMBING EQUIPMENT DESIGNATION FD-1 FLOOR DRAIN 2 1% 1/2" - ZURN ZN415B INJURY TO HANDICAPPED. <br /> I I FD FLOOR DRAIN T.P. W/ TRAP PRIMER CONNECTION 12. EACH HOT WATER HEATER SHALL HAVE A SHUT-OFF VALVE AND FLEXIBLE WATER GARY WANG <br /> CONNECTORS AT BOTH INLET & OUTLET CONNECTIONS, AND SHALL ALSO HAVE A7'd <br /> ® FS FLOOR SINK COMBINATION PRESSURE, TEMPERATURE RELIEF VALVE, WITH DISCHARGE PIPED &ASSOCIATES, INC. <br /> ( E ) EXIST'G EXISTNG FS-1 FLOOR SINK 3" 2„ - - ZURN ZN1900 TO FLOOR SINK. <br /> 13. SEAL ALL OPENINGS AROUND PIPES PENETRATING THE FIRE RATED WALLS WITH E 1000 Corporate Center Dr., Suite 550 <br /> N ) NEW APPROVED FIRE RETARDING MATERIALS. Monterey Park, CA 91754 <br /> R RELOCATE TP-114. GAS APPLIANCES TO HAVE INTERMITTENT IGNITION DEVICES. TEL: (626)288-6898 FAX: (626)768-7101 <br /> TRAP PRIMER - - 1/2" - PRECISION PLUMBING PRODUCTS http://www.garywang.com <br /> 15. INSTALL GAS VALVES AND FLEXIBLE CONNECTORS AT EACH GAS APPLIANCE PER <br /> YB YARD BOX <br /> CODE. <br /> ABV ABOVE AO SMITH DEN-52, 50 GALLONS STORAGE CAPACITY 16. NOT USED. <br /> VCP VITRIFIED CLAY PIPE WH-1 WATER HEATER - - - - 12 KW INPUT (SIMULTANEOUS WIRING), 208V-30 17. ALL SINKS MUST BE EQUIPPED WITH HOT & COLD WATER DISPENSED FROM STAMP <br /> 61 GPH RECOVERY AT 80' RISE MIXING FAUCETS. <br /> VTR VENT THRU. ROOF 18. ALL THREADED WATER OUTLETS SHALL HAVE AN APPROVED VACUUM BREAKER <br /> CLG CEILING PROPERLY INSTALLED. <br /> 19. ALL NECESSARY PLUMBING CONNECTIONS TO FIXTURE AND EQUIPMENT TO BE <br /> AP ACCESS PANEL MADE BY THE RESPECTIVE PLUMBING CONTRACTORS. USED AR�Hi <br /> IE INVERT ELEVATION 20. CONTRACTOR TO LABEL ALL FIXTURE UNITS THAT REQUIRE A BACKFLOW PREVENTION <br /> DEVICE BY LOCAL CODE. <br /> B.G. BELOW GRADE 21. ALL WASTE & GAS VENTS ARE TO BE KEPT 5' FROM PROPERTY LINE, AT POINT * No. C32569 <br /> _ cnRE .04-3D-.2,019 <br /> _ <br /> ASO AUTOMATIC SHUT OFF VALVE OF ROOF PENETRATIONS. �64 - 019 Q <br /> 22. PLUMBING FIXTURES SHALL BE AMERICAN STANDARD, KOHLER, OR EQUAL. ~� 9l, <br /> GPR GAS PRESSURE REGULATOR 23. ALL A/C CONDENSATE LINE TO BE INSTALLED BY PLUMBING CONTRACTOR. REFER or <br /> RPPBP REDUCED PRESS. PRINCIPLE BACKFLOW PREVENTER TO MECHANICAL DRAWINGS FOR LOCATION OF CONDENSATE. <br /> MG MEDIUM PRESSURE GAS 24. INSTALL EXPANSION JOINTS IN THE VENT, WASTE, SOIL PIPING, AND EXPANSION <br /> LOOPS IN THE WATER AND GAS PIPING AS REQUIRED BY THE LOCAL ADMINISTRA- <br /> TIVE AUTHORITY. <br /> 25. CONNECTIONS BETWEEN TWO DISSIMILAR METAL PIPES SHALL BE MADE OF WITH PROJECT NAME/ADDRESS: <br /> DIELECTRIC UNIONS. <br /> 26. PLUMBING CONTRACTOR SHALL COORDINATE HIS WORK CAREFULLY WITH THE AIR <br /> CONDITIONING AND ELECTRICAL CONTRACTORS TO AVOID INTERFERENCES. JUICE IT UP! <br /> PIPE MATERIAL SCHEDULE 27. ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND RIPON TOWN SQUARE <br /> ALL EXPOSED PIPING SHALL BE RUN HIGH AS POSSIBLE AND TIGHT TO WALLS. <br /> 28. SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE OR PLAN REQUIREMENTS 1201 W. MAIN ST., <br /> SERVICE UNDERGROUND ABOVE GROUND VERIFY WITH ENGINEER WHEN IN DOUBT. RIPON, CA 95366 <br /> 29. PLUMBING CONTRACTOR TO BE RESPONSIBLE FOR REMOVAL OF EXISTING <br /> HARD TEMPER, COLD DRAWN COPPER HARD TEMPER, COLD DRAWN COPPER <br /> COLD & HOT WATER TUBE TYPE "K" TUBE TYPE "L„ UNUSED PLUMBING FIXTURES, PIPING, VALVES, FITTINGS, ETC. PATCH & CAP <br /> OFF THE EXISTING SYSTEM WHERE IT APPLIES. <br /> SANITARY WASTE CAST IRON/ABS CAST IRON/ABS REVISIONS: <br /> 30. WATER SUPPLY CONNECTIONS TO EQUIPMENT, APPLIANCES AND FIXTURES SHALL Q _ <br /> BE PROVIDE WITH A SHUTOFF VALVE. CROSS-CONNECTION SHALL BE PROVIDED IN <br /> SANITARY VENT CAST IRON/ABS CAST IRON/ABS ACCORDANCE WITH CPC SEC. 603.0. D - <br /> 31. ALL SANITARY SEWER PIPING IS TO BE SLOPED A MINIMUM OF 2% (1/4" PER FOOT) <br /> GAS BLACK STEEL, SCHEDULE 40 UNLESS SPECIFICALLY APPROVED BY THE AUTHORITY HAVE JURISDICTION. (CPC 708.1) ® - <br /> A - <br /> HARD TEMPER, COLD DRAWN COPPER © - <br /> INDIRECT DRAIN TUBE TYPE "M" 8 <br /> ISSUE DATE: <br /> 1ST - <br /> CONSTRUCTION NOTES. 2ND - <br /> 3RD - <br /> 1 CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING THIS JOB TO 4TH - <br /> 5TH <br /> FAMILIARIZE HIMSELF AS TO THE EXTENT OF WORK REQUIRED, AND EXISTING <br /> 6TH <br /> CONDITION, AND SHALL TAKE THESE INTO CONSIDERATION IN THE COST OF <br /> HIS BID. <br /> 2. CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF THE JOB NUMBER <br /> UTILITIES BEFORE STARTING TRENCHING WORK. <br /> 3. CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL ARCH PROJECT#: 18-287 <br /> PERMITS & PAYING ALL FEES REQUIRED FOR WORK SHOWN ON <br /> THESE DRAWINGS. <br /> 4• THE DRAWINGS ARE DIAGRAMMATIC. THE LOCATION OF THE DRAWN BY CHECKED BY <br /> PIPING IS APPROX. COORDINATE THE LOCATION OF PIPING WITH JR ADR <br /> OTHER TRADES. ANY CONFLICTS WITH OTHER TRADES <br /> SHALL BE RESOLVED PRIOR TO INSTALLATION. SHEET CONTENT <br /> GENERAL NOTES, <br /> LEGENDS <br /> AND SCHEDULE <br /> SHEET NO <br />