Laserfiche WebLink
m <br /> z <br /> RESTROOM NOTES <br /> t= <br /> • NO WORK IN THIS AREA; <br /> EXISTING TO REMAIN, U.N.O. <br /> U <br /> N <br /> W <br /> W <br /> a <br /> J WOMENS <br /> II I 104 � <br /> II I N.I.C. ��-- <br /> II <br /> N 0 co <br /> o to <br /> Z = w � N N O N <br /> 3Y tn = >' wo a I <br /> FREEZER I I I I 0 U Q N . <br /> 0 o I I z v0U <br /> O <br /> 11 1 I I r I I ARCHITECT OF RECORD: <br /> p I SEo ARoy <br /> 0 0 3 I -- -- -------- iT <br /> O 8 I I I I I V CRAIG S. <br /> C _ I - I I I ® BLUME- <br /> ' ° I ir7r7 N .- -31661 <br /> 0 <br /> STORAGE I O O O -- -- ------J REN.3/31/2021 co <br /> ly <br /> 105 I I I �J I i — Ar7r7 2�oy �yy <br /> N.I.C. I I 1 i pyo �o <br /> I I MENS I <br /> 103 <br /> CUSTOMERI L — — — <br /> eeeeN.I.C. SERVICE I OI 11 a- 0 <br /> 100 I TYP. ""E <br /> COOLER 0 I — — — , o <br /> 1 10 1 1 1 4 r DINING 0 " <br /> T7T7 <br /> N.I.C. TYP. I (01 (o ir7 r7 a <br /> — -1 I �]E] 1 OO <br /> ilEE <br /> II 7 I 1 I I I �, <br /> ® o � 1u <br /> 8 I I � <br /> I I I La0CREW ROOM -- IDINING NOTESa �o <br /> I 1 5 L - - J NO WORK IN THIS AREA; <br /> 0 <br /> 109 I I i 10 EXISTING TO REMAIN, U.N.O. L-_---J a N o 3 <br /> N.I.C. OFFICE I 11 L u 1 <br /> 108 / \ \ LJ Li I � g I L — — — 00000 O ° � �v • rN <br /> N.I.C. 2 +. a� .r o v <br /> ° ° o �-°o '0.0 <br /> U aL � novo <br /> KITCHENC:=l — — `o0 0-00.0 a� 0 <br /> o Lv .o 0-o <br /> L_ L E=l102 10 I1:1 El E] 1:1 •, a � ao � �.. <br /> 5 • 007) o ° v c <br /> 000 r7r7 0 <br /> a� ado <br /> I <br /> 0% <br /> � +' ma,+� mod <br /> 0-`i <br /> I I o w , ()� ° r'aia <br /> I D 0 <br /> N <br /> U C 00.3., 0 0 , <br /> ° C <br /> 0°ctr <br /> � Looc <br /> KITCHEN & BOH NOTES c <br /> • NO WORK IN THIS AREA; 6 i °•' o ` <br /> C V L V r- O L y <br /> EXISTING TO REMAIN, U.N.O. <br /> ® \ / <br /> ffimnwnwmm <br /> T\ / "� c00 <br /> m ° ` mw <br /> ,0 ,�o <br /> ORDER — — — — PRESENTEREI O a N.- ` <br /> 107 106 Q -° :02-0 ,, <br /> dl N <br /> Ln E, F -------------- 0 07 <br /> N.I.C. � N.I.C. LEGEND V �,� 0t.0�,o° <br /> C = _ EXISTING CONSTRUCTION TO o o 0-020 0 <br /> BE REMOVED <br /> 07 °Z Uc <br /> N N NU <br /> o <br /> EXISTING CONSTRUCTION 0- <br /> 004, mH cTO REMAIN a3 aid <br /> 0- <br /> DEMO <br /> DEMO PLAN <br /> D1 .1 1/4" = 1 '-0" <br /> GENERAL NOTES DEMOLITION KEYNOTES <br /> 1. REFER TO A1.1 FOR NEW PLAN CONFIGURATION. VERIFY ALL DIMENSIONS OF REBAR INTO EXISTING SLAB W/ EPDXY GROUT. REPLACE OR REPAIR ANY 18. GC TO VERIFY EXISTING MCCAFE SYSTEM INSTALLATION PER THE FOLLOWINGO EXISTING DIGITAL MENU BOARDS TO BE REMOVED <br /> DEMOLITION WITH A1.1 VAPOR BARRIERS DISTURBED DURING EXCAVATIONS. CRITERIA REQUIRED BY THE ORANGE COUNTY HEALTH DEPARTMENT- <br /> 2. DIMENSIONS ARE TO FACE OF FINISH AND/OR TO COLUMN REFERENCE LINES, 9. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO 18.1. MILK TUBING OUT OF TEMPERATURE CONTROL SHALL NOT EXCEED 18 REMOVE EXISTING INTERIOR WALL PARTITION. PATCH/REPAIR <br /> U.N.O. MAINTAIN STRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL INCHES. O ADJACENT INTERIOR WALLS AND FLOORS IN KIND <br /> 3. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A PHASES OF CONSTRUCTION. 18.2. THE UNIT DRAINS DIRECTLY TO A FLOOR SINK VIA A RIGID LINE. <br /> ALL HOLES AND GAPS THROUGHOUT THE UNIT MUST BE SEALED WITHIN REMOVE EXISTING PARTIAL HEIGHT WALL3. <br /> SITE SURVEY. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD 10. PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS, FLOORS, 18. 3 <br /> PRIOR TO DEMOLITION & NOTIFY THE ARCHITECT IN CASE OF DISCREPANCIES CEILINGS, ETC. THAT ARE TO REMAIN. CONTRACTOR TO PATCH & REPAIR ANY AN EIGHTH OF AN INCH WITH APPROVED MATERIALS (SUCH AS PLASTIC, <br /> IMMEDIATELY. DEMOLITION IS TO BE EXECUTED SO AS NOT TO DISTURB DAMAGED PORTIONS OF THE EXISTING BUILDING AS REQUIRED TO MATCH THE FOOD-GRADE SILICONE, AND/OR STAINLESS STEEL). REMOVE EXISTING COUNTER SYSTEM <br /> EXISTING STRUCTURAL & ROOFING SYSTEMS, AND OTHER AREAS THAT ARE EXISTING ADJACENT CONSTRUCTION & FINISHES. 18.4. ALL TUBING MUST BE TRANSPARENT. O4 <br /> INTENDED TO REMAIN INTACT. VERIFY ALL CONSTRUCTION TO BE REMOVED a <br /> THAT IS NOT INTEGRAL TO STRUCTURAL SYSTEM PRIOR TO DEMOLITION UNLESS 11. THIS PLAN INDICATES A GENERAL SCOPE OF WORK TO BE PERFORMED AND O REMOVE EXISTING McCAFE COUNTER AND WALL SYSTEM } <br /> NOTED. DOES NOT RELIEVE THE CONTRACTOR TO COMPLETE THE BUILDING <br /> MODIFICATIONS AS SHOWN AND REQUIRED BY THE CONTRACT DOCUMENTS, <br /> 4. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL & HVAC WORK. EXISTING SSBB TO REMAIN; PROTECT DURING CONSTRUCTION. w <br /> CONTRACTOR PRIOR TO DEMOLITION. VERIFY ALL DEMOLITION WORK W/ NEW <br /> CONSTRUCTION & INSTALLATION DRAWINGS PRIOR TO BEGINNING 12. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION <br /> OR CONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK & NOTIFY THE <br /> CONSTRUCTION. MCDONALD'S AREA CONSTRUCTION MANAGER BEFORE PROCEEDING. O EXISTING VALANCE TO REMAIN Q CD w z m <br /> 5. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION U z 0 w <br /> DOCUMENTS & DETERMINE THE EXTENT OF DEMOLITION WORK & BECOME 13. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER & IN STRICT Y _ m <br /> w M <br /> FAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY DEMOLITION ACCORDANCE WITH OSHA REGULATIONS. O EXISTING KIOSK TO REMAIN U 0 <br /> cn <br /> WORK. BY THE ACT OF STARTING DEMOLITION, THE CONTRACTOR WILL BE14. THE SUB-CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE Q J x _ <br /> DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED SUCH WORK INCLUDES, BUT IS NOT LIMITED TO THE DEMOLITION AND REMOVAL OF EXISTING KITCHEN EQUIPMENT TO BE REMOVED m L = 00 <br /> CONDITIONS, AND TO HAVE MADE THE NECESSARY ALLOWANCES IN PREPARING ANY WALLS, COUNTERS, FURNITURE, BULKHEADS, DOORS, PLUMBING, O m w a cn <br /> HIS BID. MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS Z w N <br /> SHOWN ON THE DRAWINGS OR AS REQUIRED TO COMPLETE THE INSTALLATION O EXISTING KITCHEN EQUIPMENT TO BE RELOCATED. SEE A1.1 Q w cn N <br /> 6. ELECTRICAL DEMOLITION NOTE: REFER TO ELECTRICAL DRAWINGS FOR DETAILED OFTHE NEW WORK FOR A COMPLETE JOB. 10 FOR NEW LOCATION (� ¢ w <br /> ELECTRICAL DEMOLITION NOTES. Z_ Z U U <br /> 7. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK, LIGHTING FIXTURES, ETC. 15. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, EXISTING LIGHT FIXTURES TO BE REMOVEDa w 0 <br /> TO BE REMOVED W/ OWNER. ALL ITEMS TO BE DISPOSED SHALL BE <br /> NOTED ON DRAWINGS AS WELL AS ALL ASSOCIATED PLUMBING ACCESSORIES. 11 (n w o <br /> — - I <br /> CAP, PLUG ALL ABANDONED SUPPLY & WASTE LINES. PATCH & SEAL ALL w <br /> DISPOSED OF OFF-SITE AND IN AN EXPEDITIOUS MANNER. O X a <br /> cn 0 w 0 <br /> FLOOR PENETRATIONS. SEE MECHANICAL & PLUMBING DRAWINGS FOR <br /> It= W o U w N 000 <br /> 8. SAWCUT & REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND DETAILED DEMOLITION NOTES. <br /> ELECTRICAL & PLUMBING LINES. REFER TO PLUMBING, ELECTRICAL & KITCHEN <br /> DRAWINGS FOR ALL SAWCUTS & TRENCHING WORK REQUIRED. ALL CONCRETE 16. WHEN UTILITIES ARE REMOVED, CAP & SEAL A MINIMUM OF 8" BELOW FINISH <br /> FLOOR WORK TO BE FINISHED FLUSH WITH EXISTING FLOOR. DOWEL NEW FLOOR OR A MINIMUM OF 6" ABOVE FINISH CEILING. z <br /> SLABS TO EXISTING W/ #4 REBAR ® 24" O.C. EACH SIDE (STAGGERED). 17. SEE D2.1 DEMOLITION ELEVATIONS, IF REQUIRED, FOR EXTENT OF EXTERIOR w • <br /> REBAR TO EXTEND 6" INTO EXISTING SLAB & ACROSS CUT OPENING. SECURE DEMOLITION. D 1 <br /> cn DEMO PLAN <br />