Laserfiche WebLink
COMP. <br />RM. <br />MULTI-PURPOSE/ <br />CAFETERIA <br />KITCHEN <br />STAFF <br />LUNCH <br />ROOM <br />RR 3 JAN. <br />A101 <br />STAGE <br />A102 <br />MECH <br />A103 <br />DRY FOOD <br />A104 <br />A105 <br />A106 A108 <br />A107 <br />1. MAINTAIN A MINIMUM OF 10'-0" CLEARANCE FROM FACE OF <br />KITCHEN HOOD(S) AND EDGE OF SUPPLY AIR GRILLE. <br />1 COORDINATE FINAL LOCATION OF TRANSFER AIR WALL GRILLE <br />WITH EXISTING DEVICE(S) ON WALL. <br />SHPI <br />A3 <br />1 <br />SHPI <br />A2 <br />KEF <br />A1 2 <br />CEF <br />A1 <br />SHPI <br />A1 <br />TA <br />125F <br />36X20 <br />36X20 SG <br />36X20 <br />TA <br />36X20 <br />36X20 <br />36X20 SG <br />36X20 SG <br />36X20 <br />36X20 <br />1336 CFM <br />1336 CFM <br />1336 CFM <br />5" DIA. OA <br />5" DIA. OA HOOD, <br />COORDINATE <br />LOCATION THRU WALL <br />WITH FIELD <br />CONDITIONS. WITH <br />"S&P" METAL LOUVER <br />SHUTTER. <br />"S&P" FILTER <br />BOX - FB5 <br />"S&P" INLINE FAN <br />(PV-100) <br />CONDENSATE, SEE <br />PLUMBING PLANS. <br />REFRIGERANT <br />RL/ RS PIPING <br />ABOVE CEILING. <br />REFRIGERANT RL/ RS <br />PIPING (R)/(D) <br />THROUGH DOGHOUSE <br />ON ROOF.1 <br />1 <br />16x16 FIRE <br />WRAPPED 10x8L8x6 WALL CAP <br />2 <br />2 MODIFY THE EXISTING OPENING IN THE WALL TO ACCEPT THE <br />NEW 8x6 WALL EYEBROW VENT AND SCREEN. <br />MECHANICAL1000f1000f1000f1000f <br />1000f 1000f 1000f 1000f <br />RA <br />500F <br />500F <br />RA <br />DUCT (R) <br />(R)(D) <br />AC/1 <br />TAKE PRE-DEMOLITION AIR FLOW READINGS IN MULTI-PURPOSE/ <br />CAFETERIA. PROVIDE AIRFLOW READINGS TO ARCHITECT.3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />REFRIGERANT <br />PIPING DOGHOUSE <br />ON ROOF ABOVE. <br />RL/RS PIPING <br />ABOVE CEILING.RLRSRLRSRLRSRLRS <br />REFRIGERANT <br />RL/ RS PIPING <br />ABOVE CEILING. <br />5" DIA. OA <br />5" DIA. OA HOOD, <br />COORDINATE <br />LOCATION THRU WALL <br />WITH FIELD <br />CONDITIONS. WITH <br />"S&P" METAL LOUVER <br />SHUTTER. <br />"S&P" FILTER <br />BOX - FB5 <br />"S&P" INLINE FAN <br />(PV-100) <br />2 <br />T <br />6x6 CRL <br />45 CFM <br />RLRSNEW 36X20 TRANSFER AIR GRILLE AND DUCT THROUGH 38X22 <br />WALL OPENING. BOTTOM OF DUCT AT 9'-8" ABOVE FINISHED <br />FLOOR. <br />4 <br />4 <br />4 <br />12X14 FIRE <br />WRAPPED <br />12X10 FIRE <br />WRAPPED <br />TRANSITION FROM HOOD CONNECTION SIZE TO 12X10. DUCT <br />SHALL BE FIRE WRAPPED.5 <br />TRANSITION FROM HOOD CONNECTION SIZE TO 12X14. DUCT <br />SHALL BE FIRE WRAPPED.6 <br />5 <br />6 <br />(E) DOWNSPOUT <br />ALONG EXTERIOR <br />OF BUILDING. <br />(E) DOWNSPOUT ALONG EXTERIOR OF BUILDING. COORDINATE <br />INSTALLATION OF KEF-A1 WITH (E) DOWNSPOUT. OFFSET <br />DOWNSPOUT TO THE OTHER SIDE OF THE WINDOW IF SITE <br />CONDITIONS DO NOT PERMIT INSTALLATION AS NOTED. <br />7 <br />7 <br />T(E) TS250 <br />CONTROLLER/ <br />GATEWAY W/ <br />ETHERNET DROP <br />T(E) TS250 <br />IOAF <br />A1 <br />IOAF <br />A2 <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XXKITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />12/11/2019 <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />FILE NO. 39-50 APP NO. 02- <br />XX <br />AS NOTED <br />L:\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\M2.2.dwg - December 12, 2019 06:05 PM - Richard LingoM2.2 MECHANICALENLARGED FLOOR PLAN