Laserfiche WebLink
FLASHING, CAULK AND SEAL <br />SPACE AROUND PIPE22 GAUGE REMOVABLE TOP COVER <br />1 1/2" LINER <br />WITH NEOPRENE <br />2" <br />ROOFING <br />#10 SHEET METAL SCREWS <br />ROOFING <br />BLOCKING 10" MIN.6"PITCHED 18GA <br />WELDED CURB <br />1/4"X3" SIMPSON SDS <br />4" FROM EACH END <br />36" O.C. MAX <br />2 PER SIDE MIN. 3" MIN. SECURE RAIL W/ 1/2" DIA LAG SCREW <br />AT EACH 4x6 BLOCK. LAG SCREW <br />SPACING @ 24" O.C. AND MIN. (2) PER <br />SIDE <br />4x6 BLOCKING @ 2'-0" <br />O.C. MIN (2) PER <br />RAIL <br />SIMPSON <br />HU46 EA <br />END OF <br />BLOCK <br />ROOF FRAMING <br />PER <br />STRUCTURAL <br />RIGID INSULATION <br />BUILT UP ROOFING <br />SYSTEM <br />3/4" PLYWD PLATFORM W/ 8d <br />@ 6"O.C. TO 6x RAILS <br />SELF-ADHERED FLASHING <br />(SAF)24 GA. G.S.M. FLASHING CAP; <br />SOLDER ALL JOINTS <br />WATERTIGHT, SECURE TO <br />RAILS W/ GASKETED <br />SCREWS, MIN (2) PER SIDE <br />AND @ 24" O.C., TYP <br />6x RAILS MIN 6" HIGH, <br />SHAPE TO LEVEL <br />UNIT ALL SIDES W/ <br />SIMPSON A33 AT <br />CORNERS <br />CANT STRIP <br />SYSTEM C.U. AND <br />OUTDOOR SPLIT <br />SECURE EACH LEG TO CURB WITH <br />1/2" DIA. x 4" LAG BOLT, TYP. FOR 4. <br />H.P. UNIT. <br />4" x 4" BLOCKING <br />3" x 3" x 18 GA. CLIP SECURED <br />TO STUDS WITH (2) - 1/4" DIA. x <br />1-1/2" LAG BOLTS <br />SECURE CLIP TO <br />BLOCKING WITH (2) - <br />1/4" DIA. x 1-1/2" LAG BOLTS. <br />WOOD STUD WALL <br />MOUNTING BRACKET <br />(BY UNIT MFR.)3/8" DIA. x 2" LAG BOLT, <br />TYPICAL FOR 8.(2) - 1-1/2"x 1-1/2"x 3/16"x 2" WIDE ANGLES, <br />SECURE TO UNIT WITH #14 x 3/4" S.M. SCREWS & <br />TO WALL STUD WITH 3/8" DIA. x 2" LAG BOLTS. <br />SECURE ANGLES AS CLOSE TO QUARTER POINTS <br />OF UNIT AS EXISTING STUDS WILL ALLOW. <br />INSULATED <br />REFRIG. SUCTION <br />REFRIG. LIQUID <br />TYPICAL <br />TYPICAL <br />CONTROL WIRING CONDUIT, <br />AS REQUIRED, <br />"B-LINE" B22 <br />CHANNEL LENGTH AS REQ'D <br />REQUIRED <br />W/ BOLT & NUT, SIZE AS <br />"B-LINE" B-2000 PIPE CLAMP <br />INSULATED PIPING <br />16 GAx 6" LONG SM SLEEVE <br />AT PIPE CLAMP, TYP. ON <br />ALL CHANNELS AND FITTINGS SHALL BE ELECTRO-GALVANIZED.1. <br />NOTES: <br />PROVIDE CHANNLES AT 4'-0" O.C. <br />16 GA GALV. SM COVER. <br />PAINT TO MATCH ADJACENT <br />SURFACE. PROVIDE AT ALL <br />REFRIG. PIPING EXPOSED <br />OUTDOORS. <br />SECURE CHANNEL TO BLOCKING BETWEEN <br />STUDS W/ (2) 3/8" DIA. LAG BOLTS W/ MIN. <br />2-1/4" EMBEDMENT INTO BLOCKING.4x STRUCTURAL BLOCKING SECURE <br />BETWEEN WALL STUDS W/ <br />"SIMPSON" A34 FRAMING ANGLE <br />EACH END, EACH SIDE. <br />CAP ALL ENDS WATER TIGHT (HEMMED AND SEALED).2. <br />3. <br />2. <br />1. <br />CONC. PAD <br />ALL CHANNELS AND FITTINGS SHALL BE ELECTRO-GALVANIZED. <br />SPACE PIPE SUPPORTS ON GRADE AT 4' O.C. MIN. 2 SUPPORTS. <br />SEE PLANS FOR NUMBER OF PIPES ON EACH SUPPORT. <br />INSULATED PIPING <br />AT PIPE CLAMP (TYP). ON <br />16 GA x 6" LONG SM SLEEVE <br />CHANNEL LENGTH AS REQ'D <br />'UNISTRUT' P1001 DOUBLE NOTES: <br />SECURE CD TO CHANNEL <br />WITH UNISTRUT PIPE <br />CLAMPS, SECURE RL/RS <br />PIPES TO CHANNEL WITH <br />UNISTRUT <br />COPPER TUBING CLAMPS. <br />6"MIN. <br />4.ALL EXPOSED METAL PARTS INCLUDING SHEET METAL COVER SHALL BE <br />PRIMED AND PAINTED TO MATCH ARCHITECTURAL SURROUNDING SURFACE. <br />CAP ALL ENDS WATER TIGHT (HEMMED AND SEALED).5. <br />PAINT GALV. COVER TO MATCH <br />ADJACENT SURFACE (TYP). <br />16 GA GALV. SM COVER OVER <br />REFRIGERANT LINES AT GRADE & AT <br />WALL. <br />SECURE ANGLE FITTING TO <br />CHANNEL W/ SPRING CHANNEL NUT & <br />3/8" BOLT. <br />SECURE SM COVER TO CORNER <br />ANGLE W/ 1/4" BOLT, NUT & WASHER. <br />TACK WELD NUT TO BACK OF <br />CORNER ANGLE <br />SECURE CHANNEL TO CONC. <br />W/ (2) 3/8" DIA. SS "HILTI" <br />KWIK BOLT TZ, W/ MIN. 1-5/8" <br />EMBEDMENT. <br />'UNISTRUT' P1326 2 HOLE CORNER <br />ANGLE. <br />INSULATED REFRIG. <br />SUCTION (TYP)CONTROL WIRING <br />CONDUIT, MOUNTED <br />ON REFRIGERANT LINE <br />RACK. <br />INSULATED REFRIG. <br />LIQUID (TYP)CA, CO2 AND GAS PIPING RACKED ON WALL SIMILAR. GALV. COVER NOT REQUIRED INDOORS.6. <br />3/8" DIA. HANGER <br />"B-LINE" PIPE <br />CLAMP, TYP. <br />REQUIRED, SECURE TO <br />ROD W/ DOUBLE NUTS <br />"B-LINE" CHANNEL, LENGTH AS <br />REFRIGERANT PIPES, TYP. <br />3/16"x 2-1/2" BENT PLATE CLIP. <br />1 <br />1 MAX. <br />U-BOLT CLIPS <br />LOOP ON CABLE OVER WIRE <br />ROPE THIMBLE, SECURE <br />1/2" DIA. PIN SHACKLE TO CLIP <br />1/8" DIA. STEEL CABLE SWAY <br />BRACE (SPLAYED AT 45 DEGREES)SPACED AT 48" MAX O.C. <br />CONTROLS <br />CONDUIT. <br />ROD. <br />ROD STIFFENER IF > 18", <br />SEE 9/M5.11 <br />FOR UPPER ATTACHMENT <br />TO STRUCTURE, SEE <br />5/M5.12 (TYP)SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XXKITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />12/11/2019 <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />FILE NO. 39-50 APP NO. 02- <br />XX <br />AS NOTED <br />L:\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\M5.1.dwg - December 12, 2019 06:06 PM - Richard LingoM5.1 MECHANICALDETAILS